8246A

( Bench-Type Digital Multimeter 8246A)


Features

>
DC
voltage
Range:

50mV/500mV/5V/50V/500V/1000V.
>
Basic accuracy:0.025%+5dgt).
>
AC voltage Range:50mV/500mV/5V/50V/500V/750V.
>
Basic accuracy: 0.7%+30dgt).

Specifications:
Project
DC voltage

AC voltage

DC current

AC current

Resistance

Capacitance
www.ttbvision.com

8246A

8246B

Range

50mV/500mV/5V/50V/500V/1000 50mV/500mV/5V/50V/500V/1000
V
V

Basic accuracy

0.025%+5dgt)

Range

50mV/500mV/5V/50V/500V/750 50mV/500mV/5V/50V/500V/750
V
V

Basic accuracy

0.7%+30dgt)

Range

500uA/5000uA/50mA/500mA/5A/ 500uA/5000uA/50mA/500mA/5A/
10A
10A

Basic accuracy

0.15%+10dgt)

Range

500uA/5000uA/50mA/500mA/5A/ 500uA/5000uA/50mA/500mA/5A/
10A
10A

Basic accuracy

0.8%+30dgt)

Range

500/5k/50k/500k /5M/50 500/5k/50k/500k /


M
5M/50M

Basic accuracy

0.05%+5dgt)

Range

10nF/100nF/1000nF/10uF/100uF 10nF/100nF/1000nF/10uF/100uF

0.025%+5dgt)

0.7%+30dgt)

0.15%+10dgt)

0.8%+30dgt)

0.05%+5dgt)

/1000uF/10mF/100mF

/1000uF/10mF/100mF

Basic accuracy

5%+5dgt)

5%+5dgt)

Range

10Hz100kHz

10Hz100kHz

Basic accuracy

0.02%+4dgt)

0.02%+4dgt)

Range

K indexing-200.0C1360.0C K indexing-200.0C1360.0C

Basic accuracy

0.5%+0.5C)

0.5%+0.5C)

Pt100-200.0C850.0C

Pt100-200.0C850.0C

0.5%+0.5C)

0.5%+0.5C)

Display words

55000

55000

The measurement rate

Quick: 20 times / sec


Slow: 5 times / sec

Quick: 20 times / sec


Slow: 5 times / sec

Automatic / manual range

Yes

Yes

Measure the true effective value

Yes

Yes

AC measurements bandwidth

50kHz

1kHz

The duty ratio

0.1%99%

0.1%99%

Diode test

yes

yes

Continuity Check

yes

yes

Four wire resistance measurements

yes

yes

Decibel measurementdBm

yes

yes

Maximum / minimum value selection


(MAX/MIN/AVG)

yes

yes

Relative value measurement(REL)

yes

yes

Data Hold

yes

yes

Cold end temperature compensation

yes

yes

Celsius / Fahrenheit temperature switchyes

yes

The speed switch

yes

yes

The input impedance

10M

10M

Data recording

Work in 50000 groups were


recorded

Work in 50000 groups were


recorded

Communication interface

Configurable isolation USB, isolated RS232 communication

Online communication

Support the SCPI command, can realize remote control instrument by


the device driver software. The powerful function, friendly manmachine interface, the user can conveniently obtain multiple data
parameters of instrument, and the data storage, processing,
management, access to data is displayed in the graphical or tabular
form.

Frequency

Thermocouple

Thermal resistance Range


Basic accuracy

www.ttbvision.com

Auto power-off

yes

yes

Display type

VFD

VFD

Power Supply

250V10%AC50Hz or 60Hz

250V10%AC50Hz or 60Hz

Power

About 5W

About 5W

Safety

CAT II 300V

CAT II 300V

Electromagnetic compatibility

IEC61326-1,Group1Class B

IEC61326-1,Group1Class B

Size

245 220 82mmdgt)

245 220 82mmdgt)

Weight

About 2kg

About 2kg

www.ttbvision.com