Professional Documents
Culture Documents
Set Basic Parameters of Cell
Set Basic Parameters of Cell
Set Basic Parameters of Cell
GCELLBASICPARA)
Function
Use this command to modify the basic Parameters of the GSM internal cell.
Note
1. The cell can support GPRS only when it is configured with the PCU.
2. If the cell supports the adjacent cell of EDGE, NC2, NACC, PACKET SI or PCU64, it must
support GPRS.
3. If the cell is modified to not support GPRS, it will not support EDGE, NC2, NACC, PACKET
SI or PCU64 adjacent cell.
Parameter
Parameter ID
Parameter
Name
IDTYPE
Index Type
Parameter Description
Unit: None
Parameter ID
Parameter
Name
Parameter Description
Cell Index
Meaning: Index of a cell, uniquely
identifying a cell in a BSC
Unit: None
Cell Name
Meaning: Name of a cell, uniquely
identifying a cell in a BSC
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Layer of The
Cell
Unit: None
Recommended Value: 3
PRIOR
Cell Priority
Meaning: This parameter controls handover
between cells at the same layer. Generally,
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Max TA
Meaning: This parameter specifies the
actual coverage area of a cell. After
Parameter ID
Parameter
Name
Parameter Description
Unit: None
FR Use
Downlink DTX Meaning: Whether the downlink
discontinuous transmission (DTX) function
is enabled for full rate (FR) calls. This
function is also restricted by the DTX
switch in the MSC. If the MSC allows the
downlink DTX for calls and the value of
this parameter(FRDLDTX) is YES, the
downlink DTX is enabled for FR calls of
Parameter ID
Parameter
Name
Parameter Description
cells.
Unit: None
HR Use
Downlink DTX Meaning: Whether the downlink DTX
function is enabled for half rate (HR) calls.
This function is also restricted by the DTX
switch in the MSC. If the MSC allows the
downlink DTX for calls and the value of
this parameter(HRDLDTX) is YES, the
downlink DTX is enabled for HR calls of
cells.
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Encryption
Algorithm
Unit: None
Minum Access
RXLEV
Parameter ID
Parameter
Name
Parameter Description
Unit: dB
Recommended Value: 8
FRULDTX
FR Uplink
DTX
Parameter ID
Parameter
Name
Parameter Description
Unit: None
HR Uplink
DTX
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Call
Reestablishmen Meaning: Whether to allow call ret Forbidden
establishment. Burst interference or blind
spots due to high buildings may lead to a
radio link failure. If a call drop is caused by
such a failure, the MS can start call reestablishment to resume the conversation.
Unit: None
Parameter ID
Parameter
Name
Parameter Description
TCH
Immediate
Assignment
Unit: None
Recommended Value: NO
DIRECTRYEN
Directed Retry
Meaning: Whether to enable a directed
retry. The directed retry is to hand over an
MS to a neighboring cell in the same
procedure as the handover. The directed
retry is an emergency measure applicable to
Parameter ID
Parameter
Name
Parameter Description
Unit: None
UL PC Allowed
Meaning: Whether to allow MS power
control
Parameter ID
Parameter
Name
Parameter Description
Unit: None
DL PC Allowed
Meaning: Whether to allow BTS power
control
Unit: None
SDCCH
Dynamic
Allocation
Allowed
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Level Report
Switch
Unit: None
Parameter ID
Parameter
Name
Parameter Description
Allow Dynamic
Shutdown of
Meaning: This parameter specifies whether
TRX
to allow the BSC6900 to enable the TRX
Intelligent Shutdown feature on a cell.
Unit: None
Adjust Voltage
Meaning: This parameter specifies whether
to enable the TRX Working Voltage
Adjustment feature. When this parameter is
set to YES, the BSC6900 supports the
feature where the power amplifier can use
different working voltages in different TRX
modulation modes.
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Diversity
Transmitter
GMSK Delay
Parameter ID
Parameter
Name
Parameter Description
Unit: bit
Recommended Value: 20
DIVERT8PSKDELAY
Diversity
Transmitter
8PSK Delay
Unit: bit
Parameter ID
Parameter
Name
Parameter Description
Recommended Value: 4
ICBALLOW
ICB Allowed
Meaning: This parameter is used to enable
the Intelligent Combiner Bypass (ICB)
function on the BCCH TRX of a cell.
This parameter specifies whether to allow
the cell to enable the ICB function. When
this parameter is set to YES, the TCHs on
the non-BCCH TRX are preferentially
assigned. In this way, the largest possible
number of idle TCHs is reserved on the
BCCH TRX, and thus the BCCH TRX
enters the ICB mode.
Unit: None
Recommended Value: NO
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Recommended Value: NO
DIVERT16QAMDELAY
Diversity
Transmitter
16QAM Delay
Parameter ID
Parameter
Name
Parameter Description
Unit: bit
Recommended Value: 4
DIVERT32QAMDELAY
Diversity
Transmitter
32QAM Delay
Parameter ID
Parameter
Name
Parameter Description
Unit: bit
Recommended Value: 4
POWERREDUCE16QAM
16QAM
Transmitter
Power Reduce
Level
Parameter ID
Parameter
Name
Parameter Description
Unit: dB
Recommended Value: 0
POWERREDUCE32QAM
32QAM
Transmitter
Power Reduce
Level
Unit: dB
Parameter ID
Parameter
Name
Parameter Description
Recommended Value: 0
CELLSCENARIO
Cell Scenario
Meaning: Information about the cell
scenario. It needs to be sent to the BTS.
Based on the information, the BTS
optimizes the allocation of resources.
Unit: None
Cell 8PSK
Power
Attenuation
Grade
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Recommended Value: 0
FASTCALLTCHTHRESHOL
D
Parameter ID
Parameter
Name
Parameter Description
Recommended Value: 0
IMMASSCBB
Immediate
Assignment
Optimized
Unit: None
Recommended Value: NO
NBAMRTFOSWITCH
TFO Switch
Meaning: Whether to enable the Tandem
Free Operation (TFO) function on the BTS
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Measure Link
Delay Switch
Parameter ID
Parameter
Name
Parameter Description
Unit: None
Example
To set cell basic Parameters of a cell (Cell Index = 44, BFEDGEMTX=YES,
LAYER=1), run the following command:
SET GCELLBASICPARA: IDTYPE=BYID, CELLID=44, BFEDGEMTX=YES, LAYER=1;