Download as pdf or txt
Download as pdf or txt
You are on page 1of 84

MOULDED CASE CIRCUIT BREAKERS

DS

Page

DTH..E

Page

DG

Page

Adjustable Overload & Fixed Short-circuit

Fixed Overload & Fixed Short-circuit

Fixed Overload & Fixed Short-circuit

release with Normal Breaking Capacity

release with High Breaking Capacity

Technical Data

Technical Data

2/11

Technical Data

2/12

2/9,2/10

release with Normal Breaking Capacity

I-t Characteristic Curves

2/26

I-t Characteristic Curves

2/27

I-t Characteristic Curves

2/28

MCCB Ordering Data

2/36

MCCB Ordering Data

2/36

MCCB Ordering Data

2/37

Accessories Ordering Data

2/45

Accessories Ordering Data

2/46

Accessories Ordering Data

2/47

Overall Dimensions

2/58

Overall Dimensions

Overall Dimensions

DH

2/56,2/57

Page

DL

Page

2/59,2/60

DTH

Page

Adjustable Overload & Fixed

Adjustable Overload & Fixed

Adjustable Overload & Fixed Short-circuit

Short-circuit release with

Short-circuit release with

release (Conventional MCCBs) with

Standard Breaking Capacity

High Breaking Capacity

High Breaking Capacity

Technical Data

2/13,2/14

Technical Data

2/15

Technical Data

2/16,2/17

I-t Characteristic Curves

2/29

I-t Characteristic Curves

2/30

I-t Characteristic Curves

2/31

MCCB Ordering Data

2/38

MCCB Ordering Data

2/39

MCCB Ordering Data

2/40

Accessories Ordering Data

2/48

Accessories Ordering Data

2/49

Accessories Ordering Data

2/50

Overall Dimensions

2/61,2/62

Overall Dimensions

2/63,2/64

Overall Dimensions

2/65,2/66

MOULDED CASE CIRCUIT BREAKERS

DX..S

Page

DX..H

Page

Adjustable Overload & adjustable Short-

Adjustable Overload & adjustable Short-

circuit with standard Breaking Capacity

circuit with high Breaking Capacity 3 & 4

3 & 4 Pole

Pole

DM

Page

Motor protection MCCBs

Technical Data

2/18,2/19

Technical Data

2/20-2/22

Technical Data

2/23

I-t Characteristic Curves

2/32-2/34

I-t Characteristic Curves

2/32-2/35

MCCB Ordering Data

2/43

Accessories Ordering Data

2/54

MCCB Ordering Data

2/41

MCCB Ordering Data

2/42

Accessories Ordering Data

2/51,2/52

Accessories Ordering Data

2/51-2/53

Overall Dimensions

Overall Dimensions

2/67-2/71

Overall Dimensions

2/67-2/75

Type 2 Co-ordination Chart

DTH Instantaneous

Page

Instantaneous MCCBs

DF

Page

Fuse Monitoring device

Technical Data

2/24

Technical Data

2/25

MCCB Ordering Data

2/44

Ordering Data

2/44

Accessories Ordering Data

2/55

Accessories Ordering Data

2/55

Overall Dimensions

2/78

Overall Dimensions

2/79

Wiring Diagram

2/79

2/76,2/77
2/83

MOULDED CASE CIRCUIT BREAKERS

L&T was the first company to introduce Moulded case circuit Breakers (MCCBs) in India. Over the years, it has developed &
enhanced the products to growing requirements of market conditions.
L&T MCCBs use latest technologies for circuit interruption under faults. These MCCBs comply with standards IS 13947, IEC 60947
and EN 60947-2 and are certified at independent and approved test authorities.
L&T offers a wide range of MCCBs with current ratings from 0.63A to 1600A in 3-Pole & 4-Pole versions & breaking capacity from
6kA to 100kA. These MCCBs are available with Thermal-Magnetic as well as with Electronic release (above 125A in DX range).
These MCCBs are available in Fixed or Drawout versions. They are also available in utilisation category A or B.
L&T MCCBs are complemented with a wide variety of internal and external accessories.

APPLICATIONS
Distribution Feeders Ideally suited for incoming and outgoing feeder circuits on distribution boards.
Transformers

Provide effective protection to distribution transformers as outgoing breakers on the LT side.

DG Sets

Used for protection and control of diesel generating sets against overloads and short circuits.

APFC Systems

Suitable for controlling LT capacitors for power factor corrections.

DC Loads

Suitable for both AC as well as DC applications. Hence find application in protecting rectifier panels.

UPS

Used for UPS & Electronic equipment protection.

Motors

Specially designed MCCBs for Motor back-up protection provide Type-2 co-ordination (as per IEC 60947)
in conjunction with suitably rated contactors and relays.

Furnaces

Suitable for high frequency systems upto 400Hz and can be used for control of high frequency furnaces.
Also used in induction furnaces along with semiconductor fuses.

WORKING PRINCIPLE
L&Ts new range of MCCBs operate on Current limiting principle. This
helps in very fast clearance (less than 10 mS) of short-circuit faults. This is
achieved by
1. Quick opening of main contacts.
2. Guiding the arc rapidly away from the contacts into the arcing chamber.
3. Quick quenching of arc by using effective arc quenching devices.
As a result peak short circuit current (Ip) is limited to cut-off current (I c).
Thus, I2t let through (proportional to the shaded area) is considerably
reduced, resulting in lower thermal stresses in downstream equipments
and connecting cables.

2/1

MOULDED CASE CIRCUIT BREAKERS

PRODUCT HIGHLIGHTS
1. Operating mechanism is quick-make, quick-break and trip free. It is independent of manual speed of operation. Contacts cannot be
teased into position, nor can the breaker be held closed under fault conditions.
2. Clear indication of ON, OFF & TRIP position.
3. Suitable for both AC & DC applications.
4. Terminals suitable for both copper & aluminium terminations.
5. Push to trip facility to verify healthiness of mechanism.
6. Wide range of site fittable accessories.
7. Low let through energy.
8. No load line bias in new range of MCCBs.
9. Rotary operating mechanism has door interlock facility with an option of defeating interlock by an authorized person.
10. Housing is made of heat resistant insulating material.
11. Silver alloy contacts have long electrical life. The mechanism is so designed there is no arcing on the current carrying part of the
contact. The strong wipe action of the contact system keeps the contact surface clear of oxide films.

MOUNTING POSITION
L&Ts new range of MCCBs can be mounted up to 900 in any direction.

MCCBs FOR MOTOR BACK-UP PROTECTION


MCCBs are increasingly being used in motor application as
a back- up protection device due to following advantages:
Low down time
Reduced running cost
No risking of single phasing
Availability of various accessories

TYPICAL MOTOR FEEDER


A typical motor protection scheme comprises a starter (contractor and thermal overload relay) and a short circuit protective device(SCPD)
e.g.MCCB.
Thermal overload relay provides close protection to the motor against single phasing and moderate overloads like stalling etc. Protection
against higher overcurrents, beyond capability of the starter including short circuit faults is offered by MCCB.
It is necessary to have proper discrimination between thermal overload relay and SCPD for any effective protection scheme. Type DM
MCCBS are hence designed with instantaneous release to ensure proper discrimination.

FUSE MONITORING DEVICE


L&Ts range of MCCBs also includes the Fuse Monitoring Device type DF, designed to monitor the operation of fuse.
In the motor feeders, where Switch Disconnector Fuse units are used for motor backup protection, there is every possibility of only one of
the three fuses blowing due to a fault, resulting in single phasing. This can be avoided by using Fuse Monitoring Device along with Switch
Disconnector Fuse units of any fuse ratings (refer page 2/79 for connection diagram).

2/2

ACCESSORIES
INTERNAL

SHUNT RELEASE
The shunt release provides remote tripping of the circuit breaker. The coil of
shunt release is designed for short time as well as continuous operation (DX
range).
The operation voltage is :
85% to 110% of the rated voltage in AC
75% to 125% of the rated voltage in DC
Shunt release coil is short time rated, micro-switch is provided in the release to
cut off the supply. Once the MCCB trips, this prevents burning of coil even if the
supply to shunt coil is continuously fed.

UNDER VOLTAGE RELEASE


The under voltage release is used for protecting the installation against low voltage
situation. The under voltage release is designed to operate when the voltage
drops below a tripping threshold. This can also be used for remote tripping &
electrical interlocking purpose.
The tripping threshold is :
35% to 70% of rated in AC
35% to 70% of rated in DC
Circuit breaker closing is possible only if the voltage exceeds 85% of the rated
voltage.

AUXILIARY CONTACT BLOCK


The auxiliary contact block is used for remote signaling and control purposes.
This consists of one or more than one potential free change-over contacts. It
indicates the circuit breaker status- whether open or closed.

TRIP ALARM CONTACT


The trip alarm contact gives tripping indication once the MCCB trips. The potential
free change- over contacts can be used for indication or for control circuit.

Note : For ordering information, refer pages 2/45 - 2/55


2/3

ACCESSORIES
EXTERNAL

FOR DX RANGE

ELECTRICAL & MECHANICAL INTERLOCK

ANNUNCIATION UNIT
Annunciation unit indicates the differential remote and local operating states
like
- Tripping by Overload release
- Tripping be Short-circuit release
- Early-alarm in the event that the Overload release setting is about to be
exceeded.
Annunciation unit has 1NO+1NC.
RESIDUAL CURRENT OPERATED RELAYS
These are factory fitted with adjustable rated fault current and delay time.
MECHANICAL INTERLOCK
For mechanical interlocking of Two or Three MCCBs with Toggle or Rotary
drive in the same distribution panel.
PARALLELING MECHANISM
For simultaneous operation of two MCCBs mounted side by side, using a
Rotary drive.
SIDE WALL OPERATOR
This is to be used for actuating the Breaker from the side of the control
panel or for changing the Rotary movement by 90o
WITHDRAWABLE UNIT
Three position Withdrawable units are available for 3 and 4 PoleMCCBs
(250A and above).

PARALLELING MECHANISM

PLUG-IN ADAPTORS
3 pole DX range of MCCBs (upto 250A) are also available with plug-in
adaptor modules.

ADAPTOR TERMINAL WITH SHROUD / SPREADER


LINKS WITH BARRIERS
Adaptor terminals / Spreader links can be connected to basic MCCBs to facilitate
termination of higher size of cables / links.
The barrier is made of material with high dielectric strength. It is used to ensure
the electrical clearance between breaker terminals. It also prevents troubles
caused by contact of conductive material to the terminals.

ADAPTOR TERMINAL

Shrouds are used on both the sides of MCCB to provide additional safety and
are made of superior insulating material with good mechanical & electrical
properties. The shrouds are designed for click-fit fixing & thus do not need any
fixing hardware. Shroud prevents accidental contact to bare terminals.

SHROUD

Note : For ordering information, refer pages 2/45 - 2/55


2/4

ACCESSORIES
EXTERNAL

ROTARY OPERATING MECHANISM


The circuit breaker has a toggle handle operating mechanism, which also serves
as swtiching position indicator ON, OFF, TRIP. But when the circuit breaker is
installed in switchgear cubicles or distribution boards, it requires to be operated
outside of the switchgear cubicles or distribution boards. The mechanism is
designed for direct attachment to the MCCB and transforms the toggle handle
movement into a rotation. It facilitates operation of MCCB when the panel door is
closed.
ITS FEATURES
Easy operation
Door interlock mechanism. It doesnt allow the circuit breaker to be ON
when the door of switchgear cubicles or distribution boards is open thus
prevents the operator from an unsafe condition.
Door interlock defeat facility. This enables only authorized personnel to open
the door with MCCB in ON condition for the purpose of inspection.

FOR DX RANGE
REMOTE OPERATOR (MOTORISED)
For remote ON and OFF of circuit breakers. Local switching by hand also
possible.

Note : For ordering information, refer pages 2/45 - 2/55


2/5

ACCESSORIES
EXTERNAL

EARTH FAULT MODULES (Type GF1, GF2, GF11)


Protection against earth faults
Built-in CBCT solid state design (GF11 to be used with external C.T.)
GF1

10 50% adjustable current setting


100 / 200 mS selectable trip time delay
Suitable for both 3 phase 3 wire & 3 phase 4 wire7 systems.
Built in test facility.
Potential free NO contact to trip MCCB through shunt trip.
Manual reset for positive fault acknowledgment

GF2

(for Technical / Dimensional Details, refer page 2/80 and 2/81)

GF11

S. S. ENCLOSURE
Enclosure is made of CRCA material with superior quality paint for better
adherence and to enhance weather resistance.
MCCB mounted in Enclosure is ideally suited to be used as fuseless mains.
Features of Enclosure
Isolable neutral
Earthing terminal
Positive indication of breaker position
Door lock and additional lock on enclosure prevents accidental switching of
MCCB.
(for Dimensional Details, refer page 2/82)

Note : For ordering information, refer pages 2/45 - 2/55


2/6

ACCESSORIES RANGE

DS

DTH..E

DG

DH

DL

DTH

DX..S

DX..H

DM

DF

Standard

Early make

General Trip alarm

Contact alarm

Separate contact alarm

Non-delayed

Off-delayed

Without early make aux. Contact

With early make aux. Contact

Remote operator

Rotary operating mechanism

Paralleling mechanism

Mechanical interlock

Castell lock

Earth-fault module

Earth-leakage module

Plug-in module

Withdrawable module

Adaptor terminals

Spreader terminals

Enclosure

Auxiliary Contacts

Under voltage release

Shunt release

l Available; Not Available


Note : Accessories mounting / location as per page 2/45 to 2/55
2/7

ACCESSORIES FOR MCCB

UV RELEASE

AUXILIARY CONTACT
BLOCK

TRIP ALARM
CONTACT

ROTARY OPERATING
MECHANISM

SHUNT RELEASE

Note : Except DX Range


2/8

TECHNICAL DATA - DS

Type Designation

DS 100

DS 125

DS 160

100

125

160

kV

V AC

415

415

415

V DC

250

250

250

50/60

50/60

50/60

690

690

690

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

17

17

32

kA

10

10

16

kA

50%

50%

50%

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 415V ac
Rated Service S.C. breaking capacity - Ics
at 415V ac
Utilisation category
Mechanical life

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Overload release setting

Fixed

Fixed

Fixed

Short Circuit release setting (+/- 20%)

9*In

9*In

8*In

kg

1.7

1.7

1.7

mm2

50

70

95

mm

16

22

22

(1NO+1NC)

(1NO+1NC)

(1NO+1NC)

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Weight
Terminal capacity

Cables
Links

Accessories
Auxiliary contacts

2/9

TECHNICAL DATA - DS

Type Designation

DS 200

DS 250

DS 400

200

250

400

kV

V AC

415

415

415

V DC

250

250

250

50/60

50/60

50/60

690

690

690

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

32

52.5

52.5

kA

16

25

25

kA

50%

50%

50%

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 415V ac
Rated Service S.C. breaking capacity - Ics
at 415V ac
Utilisation category
Mechanical life

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Overload release setting

Fixed

Fixed

Fixed

Short Circuit release setting (+/- 20%)

6*In

6*In

6*In

kg

2.4

mm2

150

300

300

mm

30

40

40

(1NO+1NC)

(2NO+2NC)

(2NO+2NC)

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Weight
Terminal capacity

Cables
Links

Accessories
Auxiliary contacts

2/10

TECHNICAL DATA - DTH...E

Type Designation

DTH 200E

DTH 250E

DTH 400E

DTH 630E

DTH 800E

200

250

400

630

800

kV

415

415

415

415

415

V DC

250

250

250

250

250

50/60

50/60

50/60

50/60

50/60

600

600

600

600

600

-5 to +55

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

III/3

105

105

105

105

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 660V ac

kA

10

10

10

10

at 550V ac

kA

25

25

25

25

at 500V ac

kA

35

35

35

35

at 415V ac

kA

35

50

50

50

50

at 380V ac

kA

50

50

50

50

at 240V ac

kA

60

60

60

60

kA

50%

50%

50%

50%

DC Breaking capacity at 250 V, L/R <= 15mS kA

20

20

20

20

20

Capacitor rating at 415 V, 50 Hz

70

100

160

240

240

Rated Service S.C. breaking capacity - Ics


at 415V ac

kVAR

Utilisation category
Mechanical life (As per standard)

Ops.

8000

8000

8000

8000

8000

Electrical life (As per standard)

Ops.

2000

2000

1200

1200

1200

Release Type

Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic

Overload release setting

Fixed

Fixed

Fixed

Fixed

Fixed

Short Circuit release setting (+/- 20%)

8*In

3-8*In

3-8*In

3-8*In

3-8*In

Weight

10

10

10

10

185

2*240

2*240

2*240

2*240

mm

36

40 (Max. 15 thk.)

1 NO + 1 NC

2 NO + 2 NC

2 NO + 2 NC

2 NO + 2 NC

2 NO + 2 NC

Shunt release

Under voltage release

Earth fault module

Rotary operating mechanism

Terminal capacity

kg
Cables
Links

mm

40 (Max. 15 thk.) 40 (Max. 15 thk.)

40 (Max. 15 thk.)

Accessories
Auxiliary contacts

2/11

TECHNICAL DATA - DG

Type Designation

DG 125

DG 200

DG 250

DG 400

125

200

250

400

kV

V AC

415

415

415

415

V DC

250

250

250

250

50/60

50/60

50/60

50/60

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

kA

10

16

25

25

kA

75%

75%

75%

75%

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated ultimate S.C. breaking capacity - Icu
at 415V ac
Rated Service S.C. breaking capacity - Ics
at 415V ac
Utilisation category
Mechanical life

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

80-100%

80-100%

80-100%

80-100%

4*In

4*In

4*In

4*In

kg

1.8

2.4

mm2

70

150

300

300

mm

22

30

40

40

(1NO+1NC)

(1NO+1NC)

(2NO+2NC)

(2NO+2NC)

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Overload release setting


Short Circuit release setting (+/- 20%)
Weight
Terminal capacity

Cables
Links

Accessories
Auxiliary contacts

2/12

TECHNICAL DATA - DH

Type Designation

DH 100

DH 125

DH 160

DH 200

100

125

160

200

kV

415

415

415

415

V DC

250

250

250

250

50/60

50/60

50/60

50/60

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

52.5

73.5

73.5

73.5

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 660V ac
kA
at 550V ac

kA

12

18

18

18

at 500V ac

kA

18

25

25

25

at 415V ac

kA

25

35

35

35

at 380V ac

kA

25

35

35

35

at 240V ac

kA

50

60

60

60

Rated Service S.C. breaking capacity - Ics


at 415V ac
kA

100%

75%

75%

50%

DC Breaking capacity at 250 V, L/R <= 15mS kA

10

10

10

10

Capacitor rating at 415 V, 50 Hz

35

50

70

70

kVAR

Utilisation category
Mechanical life

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

80-100%

80-100%

80-100%

80-100%

9*In

9*In

8*In

6*In

kg

1.7

1.7

1.7

2.4

mm2

50

50

95

150

mm

16

16

22

30

(1NO+1NC)

(1NO+1NC)

(1NO+1NC)

(1NO+1NC)

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Overload release setting


Short Circuit release setting (+/- 20%)
Weight
Terminal capacity

Cables
Links

Auxiliary contacts

2/13

TECHNICAL DATA - DH

Type Designation

DH 250

DH 400

DH 630

250

400

630

kV

415

415

415

V DC

250

250

250

50/60

50/60

50/60

690

690

690

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

73.5

73.5

73.5

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 660V ac
kA
at 550V ac

kA

18

18

18

at 500V ac

kA

25

25

25

at 415V ac

kA

35

35

35

at 380V ac

kA

35

35

35

at 240V ac

kA

60

60

60

Rated Service S.C. breaking capacity - Ics


at 415V ac
kA

75%

75%

75%

DC Breaking capacity at 250 V, L/R <= 15mS kA

20

20

20

Capacitor rating at 415 V, 50 Hz

100

160

160

kVAR

Utilisation category
Mechanical life

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

80-100%

80-100%

80-100%

6*In

6*In

6*In

kg

5.5

5.5

6.5

mm2

300

300

400

mm

40

40

2x40

(2NO+2NC)

(2NO+2NC)

(2NO+2NC)

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Overload release setting


Short Circuit release setting (+/- 20%)
Weight
Terminal capacity

Cables
Links

Auxiliary contacts

2/14

TECHNICAL DATA - DL

Type Designation

DL 100

DL 160

DL 250

DL 400

100

160

250

400

kV

415

415

415

415

V DC

250

250

250

50/60

50/60

50/60

50/60

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

105

105

105

105

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 660V ac

kA

10

10

10

10

at 550V ac

kA

25

25

25

25

at 500V ac

kA

35

35

35

35

at 415V ac

kA

50

50

50

50

at 380V ac

kA

50

50

50

50

at 240V ac

kA

65

50

65

65

kA

100%

100%

100%

100%

DC Breaking capacity at 250 V, L/R <= 15mS kA

20

25

25

25

Capacitor rating at 415 V, 50 Hz

50

70

100

160

Rated Service S.C. breaking capacity - Ics


at 415V ac

kVAR

Utilisation category
Mechanical life

Ops.

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type
Overload release setting
Short Circuit release setting (+/- 20%)
Weight

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

80-100%

80-100%

80-100%

80-100%

9*In

8*In

6 In

6 In

1.7

1.8

50

95

300

300

mm

16

22

40

40

(1NO+1NC)

(1NO+1NC)

(2NO+2NC)

(2NO+2NC)

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Terminal capacity

kg

Thermal-Magnetic

Cables
Links

mm

Accessories
Auxiliary contacts

2/15

TECHNICAL DATA - DTH

Type Designation

DTH 100

DTH 200

100

200

kV

415

415

V DC

250

250

Hz

50/60

50/60

600

600

-5 to +55

-5 to +55

III/3

III/3

kA

10

35

DC Breaking capacity at 250 V, L/R <= 15mS kA

20

Capacitor rating at 415 V, 50 Hz

kVAR

25

70

Mechanical life

Ops.

30000

8000

Electrical life

Ops.

4500

2000

Thermal-Magnetic

Thermal-Magnetic

70-100%

70-100%

700 A

8*In

1.35

mm2

70

185

mm

22.5

36

Auxiliary contacts

1 NO + 1 NC

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Rated Uninterrupted current


at 40o C - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency
Rated insulation voltage - Ui
Operating Temperature
Overvoltage category / pollution degree

Rated ultimate S.C. breaking capacity - P1


at 415V ac

Release Type
Overload release setting
Short Circuit release setting (+/- 20%)
Weight
Terminal capacity

kg
Cables
Links

Accessories

2/16

TECHNICAL DATA - DTH

Type Designation

DTH 250

DTH 400

DTH 630

DTH 800

250

400

630

800

kV

415

415

415

415

V DC

250

250

250

250

50/60

50/60

50/60

50/60

600

600

600

600

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

105

105

105

105

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue

Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 660V ac

kA

10

10

10

10

at 550V ac

kA

25

25

25

25

at 500V ac

kA

35

35

35

35

at 415V ac

kA

50

50

50

50

at 380V ac

kA

50

50

50

50

at 240V ac

kA

60

60

60

60

kA

50%

50%

50%

50%

DC Breaking capacity at 250 V, L/R <= 15mS kA

20

20

20

20

Capacitor rating at 415 V, 50 Hz

100

160

240

240

Rated Service S.C. breaking capacity - Ics


at 415V ac

kVAR

Utilisation category
Mechanical life

Ops.

8000

8000

8000

8000

Electrical life

Ops.

1200

1200

1200

1200

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

70-100%

70-100%

70-100%

70-100%

3-8*In

3-8*In

3-8*In

3-8*In

10

10

10

10

2*240

2*240

2*240

2*240

40 (Max. 15 thk.)

40 (Max. 15 thk.)

40 (Max. 15 thk.)

40 (Max. 15 thk.)

2 NO + 2 NC

2 NO + 2 NC

2 NO + 2 NC

2 NO + 2 NC

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

Release Type
Overload release setting
Short Circuit release setting (+/- 20%)
Weight
Terminal capacity

kg
Cables
Links

mm2
mm

Accessories
Auxiliary contacts

2/17

TECHNICAL DATA - DX..S (3/4 POLE)

Type Designation
Rated Uninterrupted current
at 40o C. - Ith (AC/DC)

Rated impulse withstand voltage - Uimp


Rated operational voltage - Ue

Operating Temperature

DX 200S

100

125

160

200

415

415

415

415

440

440

440

440

50/60

50/60

50/60

50/60

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

94.5

94.5

94.5

94.5

Overvoltage category / pollution degree


Rated Short-circuit making capacity - Icm

DX 160S

V
Hz

Rated insulation voltage - Ui

DX 125S

kV
V DC

Frequency

DX 100S

kA

Rated ultimate S.C. breaking capacity - Icu


at 690V ac
kA
at 500V ac

kA

12

12

12

12

at 415V ac

kA

35

35

35

35

at 230V ac

kA

45

45

45

45

Rated Service S.C.


breaking capacity - Ics (of Icu)

kA

100%

100%

100%

100%

DC Breaking capacity at 440 V

kA

20

20

20

20

Utilisation category

Rated short-time withstand current Icw (1 Sec)kA

Mechanical life

Ops.

20000

20000

20000

20000

Electrical life (AC3, 400V)

Ops.

6000

6000

6000

3500

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

80-100%

80-100%

80-100%

80-100%

6-12*In

6-12*In

6-12*In

6-12*In

Release Type
Overload release setting
Short Circuit release setting
Mechanical Shock resistance

20

20

20

20

Weight (3 - Pole)

kg

1.7

1.7

1.7

1.7

(4 - Pole)

kg

1.7

1.7

1.7

1.7

Accessories
Auxiliary contacts
Shunt release

Under voltage release

Trip indicating auxiliary contacts

Earth fault module

Rotary operating mechanism

Residual-current protection module

Remote operator

Withdrawable unit

Plug-in module

Mechanical interlock

Paralleling mechanism

Load monitoring
2/18

TECHNICAL DATA - DX..S (3/4 POLE)

Type Designation
Rated Uninterrupted current
at 40o C. - Ith (AC/DC)

Rated impulse withstand voltage - Uimp

DX 250S

DX 400S

DX 630S

250

400

630

kV

415

415

415

V DC

440

Rated operational voltage - Ue


Frequency

50/60

50/60

50/60

690

690

690

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

kA

94.5

220

220

Rated ultimate S.C. breaking capacity - Icu


at 690V ac
kA

25

25

at 500V ac

kA

12

42

42

at 415V ac

kA

35

65

65

at 230V ac

kA

45

100

100

Rated Service S.C.


breaking capacity - Ics (of Icu)

kA

100%

50%

50%

DC Breaking capacity at 440 V

kA

20

A/B

A/B

Rated insulation voltage - Ui


OperatingTemperature

Hz

Overvoltage category / pollution degree


Rated Short-circuit making capacity - Icm

Utilisation category
Rated short-time withstand current Icw (1 Sec) kA

Mechanical life

Ops.

20000

20000

20000

Electrical life (AC3, 400V)

Ops.

3500

1250

1250

Thermal-Magnetic

Electronic

Electronic

80-100%

50-100%

50-100%

6-12*In

2-12*In

2-12*In

Release Type
Overload release setting
Short Circuit release setting
Mechanical Shock resistance

20

20

20

Weight (3 - Pole)

kg

1.7

9.1

9.1

(4 - Pole)

kg

1.7

11.9

11.9

Auxiliary contacts

Shunt release

Under voltage release

Trip indicating auxiliary contacts

Earth fault module

Rotary operating mechanism

Residual-current protection module

Remote operator

Withdrawable unit

Mechanical interlock

Paralleling mechanism

Accessories

Load monitoring
2/19

TECHNICAL DATA - DX..H (3/4 POLE)

Type Designation

DX 100H

DX 125H

DX 160H

DX 200H

100

125

160

200

Rated Uninterrupted current


at 40C. - Ith (AC/DC)

Rated impulse withstand voltage - Uimp

kV

415

415

415

415

V DC

440

440

440

440

Rated operational voltage - Ue


Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature

50/60

50/60

50/60

50/60

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

220

550

220

220

20

20

20

20

Overvoltage category / pollution degree


Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 690V ac
kA
at 500V ac

kA

at 415V ac

kA

65

65

65

65

at 230V ac

kA

100

100

100

100

Rated Service S.C.


breaking capacity - Ics (of Icu)

kA

75%

75%

75%

75%

DC Breaking capacity at 440 V

kA

25

25

25

25

Utilisation category

Rated short-time withstand current Icw (1 Sec) kA

20000

20000

20000

20000

Mechanical life

Ops.

Electrical life (AC3, 400V)

Ops.

6000

6000

6000

3500

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

Thermal-Magnetic

80-100%

80-100%

80-100%

80-100%

6-12*In

6-12*In

6-12*In

6-12*In

20

20

20

20

Weight (3 - Pole)

kg

1.7

1.7

1.7

1.7

(4 - Pole)

kg

1.7

1.7

1.7

1.7

Release Type
Overload release setting
Short Circuit release setting
Mechanical Shock resistance

Accessories
Auxiliary contacts
Shunt release

Under voltage release

Trip indicating auxiliary contacts

Earth fault module

Rotary operating mechanism

Residual-current protection module

Remote operator

Withdrawable unit

Plug-in module

Mechanical interlock

Paralleling mechanism

Load monitoring
2/20

TECHNICAL DATA - DX..H (3/4 POLE)

Type Designation
Rated Uninterrupted current
at 40C. - Ith (AC/DC)

Rated impulse withstand voltage - Uimp

DX 250H

DX 400H

DX 630H

DX 800H

250

400

630

800

kV

415

415

415

415

V DC

440

Rated operational voltage - Ue


Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature

50/60

50/60

50/60

50/60

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

kA

220

440

440

275

30

30

25

Overvoltage category / pollution degree


Rated Short-circuit making capacity - Icm

Rated ultimate S.C. breaking capacity - Icu


at 690V ac
kA
at 500V ac

kA

20

65

65

45

at 415V ac

kA

65

100

100

65

at 230V ac

kA

100

200

200

100

Rated Service S.C.


breaking capacity - Ics (of Icu)

kA

75%

50%

50%

75%

DC Breaking capacity at 440 V

kA

25

Utilisation category

A/B

Rated short-time withstand current Icw (1 Sec) kA

15 (0.3 S)

Mechanical life

Ops.

20000

20000

20000

2500

Electrical life (AC3, 400V)

Ops.

3500

5000

5000

500 (AC1)

Thermal-Magnetic

Electronic

Electronic

Electronic

80-100%

50-100%

50-100%

50-100%

6-12*In

2-12*In

2-12*In

2-12*In

20

20

20

20

Weight (3 - Pole)

kg

1.7

9.1

9.1

20.4

(4 - Pole)

kg

1.7

11.9

11.9

26.4

Auxiliary contacts

Shunt release

Under voltage release

Trip indicating auxiliary contacts

Release Type
Overload release setting
Short Circuit release setting
Mechanical Shock resistance

Accessories

Earth fault module

Rotary operating mechanism

Residual-current protection module

Remote operator

Withdrawable unit

Mechanical interlock

Paralleling mechanism

Load monitoring
2/21

TECHNICAL DATA - DX..H (3/4 POLE)

Type Designation

DX 1000H

DX 1250H

DX 1600H

1000

1250

1600

kV

415

415

415

50/60

50/60

50/60

690

690

690

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

275

275

275

Rated Uninterrupted current


at 40C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue
Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 690V ac

kA

25

25

45

at 500V ac

kA

45

45

65

at 415V ac

kA

65

65

85

at 230V ac

kA

100

100

125

kA

75%

75%

75%

15 (0.3 S)

15 (0.3 S)

20 (0.3 S)

Rated Service S.C.


breaking capacity - Ics (of Icu)
Utilisation category
Rated short-time withstand current Icw (1 Sec) kA
Mechanical life

Ops.

2500

2500

2500

Electrical life (AC3, 400V)

Ops.

500 (AC1)

500 (AC1)

500 (AC1)

Release Type

Electronic

Electronic

Electronic

Overload release setting

50-100%

50-100%

50-100%

2-12*In

2-12*In

2-12*In

20

20

20

Weight (3 - Pole)

kg

20.4

20.4

20.4

(4 - Pole)

kg

26.4

26.4

26.4

Auxiliary contacts

Shunt release

Under voltage release

Trip indicating auxiliary contacts

Earth fault module

Rotary operating mechanism

Residual-current protection module

Short Circuit release setting


Mechanical Shock resistance

Accessories

Remote operator

Withdrawable unit

Side wall operator

Mechanical interlock

Load monitoring

y
2/22

TECHNICAL DATA - DM

Type Designation

DM 16

DM 100

DM 160

DM 250

DM 400

16

70

160

250

400

kV

415

415

415

415

415

50/60

50/60

50/60

50/60

50/60

690

690

690

690

690

-5 to +55

-5 to +55

-5 to +55

-5 to +55

-5 to +55

III/3

III/3

III/3

III/3

III/3

105

105

105

105

105

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp
Rated operational voltage - Ue
Frequency

Hz

Rated insulation voltage - Ui


Operating Temperature
Overvoltage category / pollution degree
Rated Short-circuit making capacity - Icm

kA

Rated ultimate S.C. breaking capacity - Icu


at 660V ac

kA

10

10

10

10

10

at 550V ac

kA

25

25

25

25

25

at 500V ac

kA

35

35

35

35

35

at 415V ac

kA

50

50

50

50

50

at 380V ac

kA

50

50

50

50

50

at 240V ac

kA

85

85

85

85

85

kA

100%

100%

100%

100%

100%

Rated Service S.C.


breaking capacity - Ics at 415V ac
Utilisation category
Mechanical life

As per standard IS 13947-2 / IEC 60947-2

Electrical life
Release Type

Magnetic

Magnetic

Magnetic

Magnetic

Magnetic

12*In

12*In

12*In

12*In

12*In

kg

1.65

4.8

5.5

5.5

mm2

10

50

185

300

300

mm

16

36

40

40

1 NO + 1 NC

1 NO + 1 NC

1 NO + 1 NC

2 NO + 2 NC

2 NO + 2 NC

Shunt release

Under voltage release

Trip alarm contacts

Rotary operating mechanism

Short Circuit release setting (+/- 20%)


Weight
Terminal capacity

Cables
Links

Accessories
Auxiliary contacts

2/23

TECHNICAL DATA - DTH 800 INST.

Type Designation

DTH 800 INST.

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp

800

kV

415

Hz

50/60

600

-5 to +55

Rated operational voltage - Ue


Frequency
Rated insulation voltage - Ui
Operating Temperature
Overvoltage category / pollution degree

III/3

Rated ultimate S.C. breaking capacity - Icu


at 415V ac

kA

50

kA

50%

Rated Service S.C. breaking capacity - Ics


at 415V ac (of Icu)
Utilisation category

Mechanical life

Ops.

8000

Electrical life

Ops.

1200

Release Type

Magnetic

Short Circuit release setting (+/- 20%)


Weight
Terminal capacity

360A, 550A, 850A, 1050A


kg

Cables
Links

10

mm2

2*240

mm

40 (Max. 15 thk.)

Accessories
Auxiliary contacts

Shunt release

Under voltage release

Trip alarm contacts

Earth fault module

Rotary operating mechanism

2/24

TECHNICAL DATA - DF

Type Designation

DF

Rated Uninterrupted current


at 40o C. - Ith (AC/DC)
Rated impulse withstand voltage - Uimp

kV

415

Hz

50/60

600

-5 to +55

Rated operational voltage - Ue


Frequency
Rated insulation voltage - Ui
Operating Temperature
Overvoltage category / pollution degree

III/3

Rated ultimate S.C. breaking capacity - Icu


at 415V ac
Magnetic Threshold

kA

50

Mechanical life

Ops.

10000

Electrical life

Ops.

6000

Overload release setting (Fixed)


Weight
Terminal capacity

kg

0.65

Without lugs

mm2

With lugs

mm2

16

Accessories
Auxiliary contact

1 CO, 5A-250V

Shunt release

Auxiliary contact

Trip alarm contacts

2/25

I-t CHARACTERISTIC CURVES


MCCB - TYPE DS

DS 100

DS 125/160

DS 200

DS 250/400

Note: Short Circuit tripping values indicated as multiple of rated current


2/26

I-t CHARACTERISTIC CURVES


MCCB - TYPE DTH...E

DTH 200E

DTH 400E

DTH 250E

DTH 630E

Note: Short Circuit tripping values indicated as multiple of rated current


2/27

DTH 800E

I-t CHARACTERISTIC CURVES


MCCB - TYPE DG

DG 125

DG 160

DG 200

DG 250/400

Note: Short Circuit tripping values indicated as multiple of rated current


2/28

I-t CHARACTERISTIC CURVES


MCCB - TYPE DH

DH 100/125

DH 160

DH 200

DH 250/400/630

Note: Short Circuit tripping values indicated as multiple of rated current


2/29

I-t CHARACTERISTIC CURVES


MCCB - TYPE DL

DL 100

DL 160

DL 250/400
Note: Short Circuit tripping values indicated as multiple of rated current
2/30

I-t CHARACTERISTIC CURVES


MCCB - TYPE DTH

DTH 100

DTH 200

DTH 250

DTH 400

DTH 630

DTH 800

Note: Short Circuit tripping values indicated as multiple of rated current


2/31

I-t CHARACTERISTIC CURVES


DX 100-250 S/H (3/4 POLE)

Note: Short Circuit tripping values indicated as multiple of rated current


2/32

I-t CHARACTERISTIC CURVES


DX 400 S/H (3/4 POLE)

2
 #

#

Note: Short Circuit tripping values indicated as multiple of rated current


2/33

I-t CHARACTERISTIC CURVES


DX 630 S/H (3/4 POLE)

Note: Short Circuit tripping values indicated as multiple of rated current


2/34

I-t CHARACTERISTIC CURVES


DX 800-1600 H (3/4 POLE)

DX 800 H

DX 1000 H

DX 1250 H

DX 1600 H

Note: Short Circuit tripping values indicated as multiple of rated current


2/35

ORDERING DATA - DS RANGE

MCCB

DS 100

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

Catalogue No. Ordering

100

16

10

16

9*In

12

SL97917

OOOO

20

10

20

9*In

12

SL97918

OOOO

25

10

25

9*In

12

SL97919

OOOO

32

10

32

9*In

12

SL97920

OOOO

40

10

40

9*In

12

SL97921

OOOO

50

10

50

9*In

12

SL97922

OOOO

63

10

63

9*In

12

SL97923

OOOO

80

10

80

9*In

12

SL97924

OOOO

100

10

100

9*In

12

SL97925

OOOO

Suffix

DS 125

125

125

10

125

9*In

12

SL97929

OOOO

DS 160

160

160

16

160

9*In

12

SL97930

OOOO

DS 200

200

200

16

200

6*In

12

SL97931

OOOO

DS 250

250

250

25

250

6*In

SL94541

OOOO

DS 400

320

320

25

320

6*In

SL94542

OOOO

400

400

25

400

6*In

SL94543

OOOO

ORDERING DATA - DTH...E RANGE

MCCB

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

Catalogue No. Ordering

DTH 200E

200

200

35

200

8*In

ST 30513

OOOO

DTH 250E

250

250

50

250

3-8*In

ST 30543

OOOO

DTH 400E

400

400

50

400

3-8*In

ST 30545

OOOO

DTH 630E

630

630

50

630

3-8*In

ST 30514

OOOO

DTH 800E

800

800

50

800

3-8*In

ST 30546

OOOO

Suffix

2/36

ORDERING DATA - DG RANGE

MCCB

DG 125

DG 200

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

125

16

10

12 - 16

6*In

SL97941

OOOO

20

10

16 - 20

6*In

SL97942

OOOO

25

10

20 - 25

6*In

SL97943

OOOO

32

10

25 - 32

6*In

SL97944

OOOO

40

10

32 - 40

6*In

SL97945

OOOO

50

10

40 - 50

6*In

SL97946

OOOO

63

10

50 - 63

4*In

SL97947

OOOO

80

10

63 - 80

4*In

SL97948

OOOO

100

10

80 - 100

4*In

SL97949

OOOO

125

10

100 - 125

4*In

SL97950

OOOO

160

16

128 - 160

4*In

SL97951

OOOO

200

16

160 - 200

4*In

SL97953

OOOO

200

Catalogue No. Ordering


Suffix

DG 250

250

250

25

200 - 250

4*In

SL97957

OOOO

DG 400

400

320

25

250 - 320

4*In

SL97958

OOOO

400

25

320 - 400

4*In

SL97959

OOOO

2/37

ORDERING DATA - DH RANGE

MCCB

DH 100

DH 125

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

100

16

25

12 - 16

9*In

SL 97201

OOOO

20

25

16 - 20

9*In

SL 97202

OOOO

25

25

20 - 25

9*In

SL 97203

OOOO

32

25

25 - 32

9*In

SL 97204

OOOO

40

25

32 - 40

9*In

SL 97205

OOOO

50

25

40 - 50

9*In

SL 97206

OOOO

63

25

50 - 63

9*In

SL 97207

OOOO

80

25

63 - 80

9*In

SL 97208

OOOO

100

25

80 - 100

9*In

SL 97209

OOOO

16

35

12 - 16

9*In

SL 98556

OOOO

20

35

16 - 20

9*In

SL 98557

OOOO

25

35

20 - 25

9*In

SL 98558

OOOO

32

35

25 - 32

9*In

SL 98559

OOOO

40

35

32 - 40

9*In

SL 98560

OOOO

50

35

40 - 50

9*In

SL 98561

OOOO

63

35

50 - 63

9*In

SL 98562

OOOO

80

35

63 - 80

9*In

SL 98563

OOOO

100

35

80 - 100

9*In

SL 98564

OOOO

125

35

100 - 125

9*In

SL 98555

OOOO

125

Catalogue No. Ordering


Suffix

DH 160

160

160

35

128 - 160

8*In

SL 98566

OOOO

DH 200

200

200

35

160 - 200

6*In

SL 97869

OOOO

DH 250

250

200

35

160 - 200

6*In

SL 97881

OOOO

250

35

200 - 250

6*In

SL 97882

OOOO

320

35

250 - 320

6*In

SL 97883

OOOO

400

35

320 - 400

6*In

SL 97884

OOOO

500

35

400 - 500

6*In

SL 94531

OOOO

630

35

500 - 630

6*In

SL 94532

OOOO

DH 400

DH 630

400

630

2/38

ORDERING DATA - DL RANGE

MCCB

DL 100

DL 160

DL 250

DL 400

2/39

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

100

16

50

12 - 16

9*In

SL 97801

OOOO

20

50

16 - 20

9*In

SL 97802

OOOO

25

50

20 - 25

9*In

SL 97803

OOOO

32

50

25 - 32

9*In

SL 97804

OOOO

40

50

32 - 40

9*In

SL 97805

OOOO

50

50

40 - 50

9*In

SL 97806

OOOO

63

50

50 - 63

9*In

SL 97807

OOOO

80

50

63 - 80

9*In

SL 97808

OOOO

100

50

80 - 100

9*In

SL 97809

OOOO

100

50

80 - 100

8*In

SL97128

OOOO

125

50

100 - 125

8*In

SL 97129

OOOO

160

50

128 - 160

8*In

SL 97130

OOOO

200

50

160 - 200

6*In

SL 97541

OOOO

250

50

200 - 250

6*In

SL 97542

OOOO

320

50

250 - 320

6*In

SL 97543

OOOO

400

50

320 - 400

6*In

SL 97544

OOOO

160

250

400

Catalogue No. Ordering


Suffix

ORDERING DATA - DTH RANGE

MCCB

DTH 100

DTH 200

DTH 250

DTH 400

DTH 630

DTH 800

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

100

16

12 - 16

700

SL 94473

OOOO

20

16 - 20

700

SL 94474

OOOO

25

20 - 25

700

SL 94475

OOOO

32

25 - 32

700

SL 94476

OOOO

40

30 - 40

700

SL 94477

OOOO

50

38 - 50

700

SL 94478

OOOO

63

48 - 63

700

SL 94479

OOOO

80

10

60 - 80

700

SL 94480

OOOO

100

10

70 -100

700

SL 94481

OOOO

100

35

70 -100

8*In

SL 94512

OOOO

125

35

90 -125

8*In

SL 94513

OOOO

160

35

120 -160

8*In

SL 94514

OOOO

200

35

140 -200

8*In

SL 94515

OOOO

175

50

125 - 175

3-8*In

SL 94466

OOOO

250

50

175 - 250

3-8*In

SL 94467

OOOO

320

50

225 - 320

3-8*In

SL 94468

OOOO

400

50

280 - 400

3-8*In

SL 94469

OOOO

500

50

360 - 500

3-8*In

SL 94470

OOOO

630

50

460 - 630

3-8*In

SL 94471

OOOO

800

50

600 - 800

3-8*In

SL 94472

OOOO

200

250

400

630

800

Catalogue No. Ordering


Suffix

ORDERING DATA - DTH 100 4-POLE


MCCB

DTH 100

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

Catalogue No. Ordering

100

100

12 - 16

700

SL 94525

OOBO

100

16 - 20

700

SL 94525

OOCO

100

20 - 25

700

SL 94525

OODO

100

25 - 32

700

SL 94525

OOEO

100

30 - 40

700

SL 94525

OOFO

100

38 - 50

700

SL 94525

OOGO

100

48 - 63

700

SL 94525

OOHO

100

10

60 - 80

700

SL 94526

OOOO

100

10

70 -100

700

SL 94525

OOOO

Suffix

2/40

ORDERING DATA - DX..S (3 POLE)

MCCB

DX 100S

Rating

Utilisation

(A)

Category

100

Current

Breaking

Rating (A) Capacity, Icu(kA)

Overload

Short-Circuit

Std.

Setting (A)

Setting

Pack

Catalogue No. Ordering


Suffix

40

35

25 - 40

9.5*In

ST 31038

OOOO

63

35

40 - 63

6-12*In

ST 31039

OOOO

80

35

63 - 80

6-12*In

ST 31040

OOOO

100

35

80 - 100

6-12*In

ST 31041

OOOO

DX 125S

125

125

35

80 - 125

6-12*In

ST 31042

OOOO

DX 160S

160

160

35

125 - 160

6-12*In

ST 31043

OOOO

DX 200S

200

200

35

160 - 200

6-12*In

ST 31044

OOOO

DX 250S

250

250

35

200 - 250

6-10*In

ST 31045

OOOO

DX 400S

400

A / B*

250

65

125 - 250

2-12*In

ST 31058

OOOO

A / B*

400

65

200 - 400

2-12*In

ST 31059

OOOO

A / B*

630

65

300 - 630

2-12*In

ST 31060

OOOO

DX 630S

630

ORDERING DATA - DX..S (4 POLE)

MCCB

DX 100S

Rating

Utilisation

(A)

Category

100

Current

Breaking

Rating (A) Capacity, Icu(kA)

Overload

Short-Circuit

Std.

Setting (A)

Setting

Pack

Catalogue No. Ordering


Suffix

40

35

25 - 40

9.5*In

ST 31001

OOOO

63

35

40 - 63

6-12*In

ST 31002

OOOO

80

35

63 - 80

6-12*In

ST 31003

OOOO

100

35

80 - 100

6-12*In

ST 31004

OOOO

DX 125S

125

125

35

80 - 125

6-12*In

ST 31005

OOOO

DX 160S

160

160

35

125 - 160

6-12*In

ST 31006

OOOO

DX 200S

200

200

35

160 - 200

6-12*In

ST 31007

OOOO

DX 250S

250

250

35

200 - 250

6-10*In

ST 31008

OOOO

DX 400S

400

A / B*

250

65

125 - 250

2-12*In

ST 31019

OOOO

A / B*

400

65

200 - 400

2-12*In

ST 31021

OOOO

A / B*

630

65

300 - 630

2-12*In

ST 31023

OOOO

DX 630S
* To be specified
2/41

630

ORDERING DATA - DX..H (3 POLE)

MCCB

DX 100H

Rating

Utilisation

(A)

Category

100

Current

Breaking

Rating (A) Capacity, Icu(kA)

Overload

Short-Circuit

Std.

Setting (A)

Setting

Pack

Catalogue No. Ordering


Suffix

40

65

25 - 40

9.5*In

63

65

40 - 63

6-12*In

80

65

63 - 80

6-12*In

100

65

80 - 100

6-12*In

DX 125H

125

125

65

80 - 125

6-12*In

DX 160H

160

160

65

125 - 160

6-12*In

DX 200H

200

200

65

160 - 200

6-12*In

DX 250H

250

250

65

200 - 250

6-10*In

DX 400H

400

250

100

125 - 250

2-12*In

ST 31046

OOOO

400

100

200 - 400

2-12*In

ST 31047

OOOO

DX 630H

630

630

100

300 - 630

2-12*In

ST 31048

OOOO

DX 800H

800

800

85

400 - 800

3-12*In

ST 31049

OOOO

DX 1000H

1000

1000

85

500 - 1000

3-12*In

ST 31050

OOOO

DX 1250H

1250

1250

85

630 - 1250

3-12*In

ST 31051

OOOO

DX 1600H

1600

1600

100

800 - 1600

3-12*In

ST 31052

OOOO

ORDERING DATA - DX..H (4 POLE)

MCCB

DX 100H

Rating

Utilisation

(A)

Category

100

Current

Breaking

Rating (A) Capacity, Icu(kA)

Overload

Short-Circuit

Std.

Setting (A)

Setting

Pack

Catalogue No. Ordering


Suffix

40

65

25 - 40

9.5*In

ST 31011

OOOO

63

65

40 - 63

6-12*In

ST 31012

OOOO

80

65

63 - 80

6-12*In

ST 31013

OOOO
OOOO

100

65

80 - 100

6-12*In

ST 31014

DX 125H

125

125

65

80 - 125

6-12*In

ST 31015

OOOO

DX 160H

160

160

65

125 - 160

6-12*In

ST 31016

OOOO

DX 200H

200

200

65

160 - 200

6-12*In

ST 31017

OOOO

DX 250H

250

250

65

200 - 250

6-10*In

ST 31018

OOOO

DX 400H

400

250

100

125 - 250

2-12*In

ST 31020

OOOO

400

100

200 - 400

2-12*In

ST 31022

OOOO

DX 630H

630

630

100

300 - 630

2-12*In

ST 31024

OOOO

DX 800H

800

800

85

400 - 800

3-12*In

ST 31025

OOOO

DX 1000H

1000

1000

85

500 - 1000

3-12*In

ST 31026

OOOO

DX 1250H

1250

1250

85

630 - 1250

3-12*In

ST 31027

OOOO

DX 1600H

1600

1600

100

800 - 1600

3-12*In

ST 31028

OOOO
2/42

ORDERING DATA - DM RANGE

MCCB

DM 16

DM 100

DM 160

DM 250

DM 400

2/43

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

16

0.63

50

0.63

12*In

SL 97581

OOOO

1.0

50

1.0

12*In

SL 97582

OOOO

1.6

50

1.6

12*In

SL 97583

OOOO

2.5

50

2.5

12*In

SL 97584

OOOO

4.0

50

4.0

12*In

SL 97585

OOOO

5.0

50

5.0

12*In

SL 97586

OOOO

6.3

50

6.3

12*In

SL 97587

OOOO

7.5

50

7.5

12*In

SL 97588

OOOO

10

50

10

12*In

SL 97589

OOOO

12

50

12

12*In

SL 97590

OOOO

16

50

16

12*In

SL 97591

OOOO

16

50

16

12*In

SL 97811

OOOO

25

50

25

12*In

SL 97812

OOOO

30

50

30

12*In

SL 97816

OOOO

35

50

35

12*In

SL 97813

OOOO

50

50

50

12*In

SL 97814

OOOO

60

50

60

12*In

SL 97817

OOOO

70

50

70

12*In

SL 97815

OOOO

100

50

100

12*In

SL 97123

OOOO

120

50

120

12*In

SL 97703

OOOO

160

50

160

12*In

SL 97124

OOOO

200

50

200

12*In

SL 97551

OOOO

230

50

230

12*In

SL 97552

OOOO

250

50

250

12*In

SL 97553

OOOO

275

50

275

12*In

SL 97554

OOOO

325

50

325

12*In

SL 97555

OOOO

350

50

350

12*In

SL 97556

OOOO

400

50

400

12*In

SL 97557

OOOO

100

160

250

400

Catalogue No. Ordering


Suffix

ORDERING DATA - DTH INST. RANGE

MCCB

DTH 800

Rating

Current

Breaking

Overload

Short-Circuit

Std.

(A)

Rating (A)

Capacity, Icu(kA)

Setting (A)

Setting

Pack

Catalogue No. Ordering

800

800

50

360

SB 95052

OOOO

800

50

550

SB 95053

OOOO

800

50

850

SB 95054

OOOO

800

50

1050

SB 95055

OOOO

Suffix

ORDERING DATA - DF
FUSE MONITORING DEVICE
MCCB

DF

Thermal Rating

Breaking

Magnetic Threshold

(A)

Capacity, Icu(kA)

(A)

50

Std. Pack

Catalogue No.

Ordering
Suffix

SL 97020

OOOO

2/44

ACCESSORIES - ORDERING DATA


TYPE DS

Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110/240/415 V AC

SL 97299

OMOO

24 V DC

SL 97299

O4OO

415 V AC

SL 97610

OOOO

240 V AC

SL 97611

OOOO

1 NO + 1 NC

SL 97296

OOOO

SL 97297

OOOO

SL 97298

OOOO

Ext.

SL 97301

OOOO

GF1

Ext.

ST 27745

OOOO

Ext.

ST 29967

OOOO

415 V AC/220 V DC

R/L

SL 97575

OOOO

240 V AC/110 V DC

R/L

SL 97576

OOOO

415 V AC

SL 97579

OOOO

240 V AC

SL 97580

OOOO

2 NO + 2 NC

L/R

SL 97573

OOOO

Trip Alarm contact

SL 97574

OOOO

Spreader Links with Barrier *

Ext.

Std. Kit

Rotary operating handle

ROM

Ext.

SL 97562

OOOO

Earth Fault module 2)

GF2

Ext.

ST 27746

OOOO

DS 100/125/160/200
Shunt Release

Under Voltage Release

Auxiliary contact Block

Trip Alarm contact

Rotary operating handle


Earth Fault module2)
S S Enclosure1)

DS 250/400
Shunt Release

Under Voltage Release

Auxiliary contact Block

Note :

2/45

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
Along with DS400
1) Dimension on page 2/82
2) Dimension and wiring diagram on pages 2/80 & 2/81

ACCESSORIES - ORDERING DATA


TYPE DTH..E
Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

415 V AC/220 V DC

SL 94331

ODOO

240 V AC/110 V DC

SL 94331

OBOO

110 V AC

SL 94331

OAOO

SL 94332

DOOO

240 V AC

SL 94332

BOOO

110 V AC

SL 94332

AOOO

SL 94330

OOOO

SL 94329

OOOO

DTH 200E
Shunt Release

Under Voltage Release*

Auxiliary contact Block

415 V AC

1 NO + 1 NC

Rotary operating mechanism

ROM

Ext.

SL 94336

OOOO

Earth Fault module1)

GF2

Ext.

ST 27746

OOOO

110 V AC

SL 98523

OOOO

415 V AC/220 V DC

SL 98526

OOOO

24 V DC

SL 98531

OOOO

240 V AC/110 V DC

SL 98534

OOOO

110 V AC

SL 98543

OOOO

240 V AC

SL 98545

OOOO

415 V AC

SL 98548

OOOO

1 NO + 1 NC

L/R

SL 94217

OOOO

DTH 250E / 400E / 630E / 800E


Shunt Release

Under Voltage Release

Auxiliary contact Block


Rotary operating mechanism

ROM

SL 94337

OOOO

Earth Fault module1)

GF11

ST 28594

OOOO

Note :

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
24 V, 48 V, 110 V & 220 V DC are also available on request
1) Dimension and wiring diagram on pages 2/80 & 2/81
2/46

ACCESSORIES - ORDERING DATA


TYPE DG

Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110/240/415 V AC

SL 97299

OMOO

24 V DC

SL 97299

O4OO

415 V AC

SL 97610

OOOO

240 V AC

SL 97611

OOOO

1 NO + 1 NC

SL 97296

OOOO

SL 97297

OOOO

SL 97298

OOOO

Rotary operating handle

Ext.

SL 97301

OOOO

Spreader Links with Barrier

Ext.

Std. Kit

GF1

Ext.

ST 27745

OOOO

Ext.

ST 29967

OOOO

415 V AC/220 V DC

R/L

SL 97575

OOOO

240 V AC/110 V DC

R/L

SL 97576

OOOO

415 V AC

SL 97579

OOOO

240 V AC

SL 97580

OOOO

2 NO + 2 NC

L/R

SL 97573

OOOO

Trip Alarm contact

SL 97574

OOOO

Spreader Links with Barrier *

Ext.

Std. Kit

Rotary operating mechanism

ROM

Ext.

SL 97562

OOOO

Earth Fault module 2)

GF2

Ext.

ST 27746

OOOO

DG 125/200
Shunt Release

Under Voltage Release

Auxiliary contact Block

Trip Alarm contact

Earth Fault module 2)


S S Enclosure 1)

DG 250/400
Shunt Release

Under Voltage Release

Auxiliary contact Block

Note :

2/47

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
To be used with DS 125 & above
1) Dimension on page 2/82
2) Dimension and wiring diagram on pages 2/80 & 2/81

ACCESSORIES - ORDERING DATA


TYPE DH
Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110/240/415 V AC

SL 97299

OMOO

24 V DC

SL 97299

O4OO

415 V AC

SL 97610

OOOO

240 V AC

SL 97611

OOOO

1 NO + 1 NC

SL 97296

OOOO

SL 97297

OOOO

SL 97298

OOOO

ROM

Ext.

SL 97301

OOOO

Ext.

Terminal shroud

Ext.

Spreader Links with Barrier

Ext.

GF1

Ext.

ST 27745

OOOO

Ext.

ST 29967

OOOO

415 V AC/220 V DC

R/L

SL 97575

OOOO

240 V AC/110 V DC

R/L

SL 97576

OOOO

415 V AC

SL 97579

OOOO

240 V AC

SL 97580

OOOO

1 NO + 1 NC

L/R

SL 97573

OOOO

Trip Alarm contact

SL 97574

OOOO

Adaptor terminal (3) with shroud (1) - 1 Set

Ext.

SL 97564

OOOO

Terminal shroud

Ext.

SL 97563

OOOO

Spreader Links with Barrier *

Ext.

Std. Kit

Rotary operating mechanism

ROM

Ext.

SL 97562

DH 100/125/160/200
Shunt Release

Under Voltage Release

Auxiliary contact Block

Trip Alarm contact


Rotary operating mechanism
Adaptor terminal with shroud

Earth Fault module 2)


S S Enclosure 1)

DH 250/400/630
Shunt Release

Under Voltage Release

Auxiliary contact Block

Earth Fault module 2)

Note :

OOOO

GF2

Ext.

ST 27746

OOOO

GF11#

Ext.

ST28594

OOOO

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
To be used with DS 125 & above
#
To be used with DH 630
1) Dimension on page 2/82
2) Dimension and wiring diagram on pages 2/80 & 2/81
2/48

ACCESSORIES - ORDERING DATA


TYPE DL

Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110/240/415 V AC

SL 97299

OMOO

24 V DC

SL 97299

O4OO

415 V AC

SL 97610

OOOO

240 V AC

SL 97611

OOOO

1 NO + 1 NC

SL 97296

OOOO

SL 97297

OOOO

SL 97298

OOOO

Ext.

SL 97301

OOOO

GF1

Ext.

ST 27745

OOOO

Ext.

ST 29967

OOOO

415 V AC/220 V DC

DL 100
Shunt Release
Under Voltage Release
Auxiliary contact Block
Trip Alarm contact

Rotary operating handle


Earth Fault module 2)
S S Enclosure 1)

DL 160
Shunt Release

Under Voltage Release*

SL 94331

ODOO

240 V AC/110 V DC

SL 94331

OBOO

110 V AC

SL 94331

OAOO

SL 94332

DOOO

SL 94332

BOOO

415 V AC

240 V AC
110 V AC
Auxiliary contact Block
Trip Alarm contact #

1 NO + 1 NC

SL 94332

AOOO

SL 94330

OOOO

SL 94329

OOOO

Rotary operating mechanism

ROM

Ext.

SL 94336

Factory assembled
OOOO

Earth Fault module 2)

GF2

Ext.

ST 27746

OOOO

415 V AC/220 V DC

R/L

SL 97575

OOOO

240 V AC/110 V DC

R/L

SL 97576

OOOO

Under Voltage Release

415 V AC

SL 97579

OOOO

240 V AC

SL 97580

OOOO

Auxiliary contact Block

1 NO + 1 NC

L/R

SL 97573

OOOO

Trip Alarm contact

SL 97574

OOOO

Spreader Links with Barrier

Ext.

Std. Kit

Rotary operating mechanism

ROM

Ext.

SL 97562

OOOO

Earth Fault module 2)

GF2

Ext.

ST 27746

OOOO

DL 250/400
Shunt Release

Note :

2/49

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
24 V, 48 V, 110 V & 220 V DC are also available on request
#
On request
1) Dimension on page 2/82
2) Dimension and wiring diagram on pages 2/80 & 2/81

ACCESSORIES - ORDERING DATA


TYPE DTH
Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

Ext.

SL 94286

OOOO

GF1

Ext.

ST 27745

OOOO

415 V AC/220 V DC

DTH 100
Rotary operating handle
Earth Fault module 1)

DTH 200
Shunt Release

Under Voltage Release*

SL 94331

ODOO

240 V AC/110 V DC

SL 94331

OBOO

110 V AC

SL 94331

OAOO

SL 94332

DOOO

415 V AC

240 V AC

SL 94332

BOOO

110 V AC

SL 94332

AOOO

SL 94330

OOOO

SL 94329

OOOO

Rotary operating mechanism

ROM

Ext.

SL 94336

OOOO

Earth Fault module 1)

GF2

Ext.

ST 27746

OOOO

110 V AC

SL 98523

OOOO

415 V AC/220 V DC

SL 98526

OOOO

24 V DC

SL 98531

OOOO

240 V AC/110 V DC

SL 98534

OOOO

110 V AC

SL 98543

OOOO

240 V AC

SL 98545

OOOO

415 V AC

SL 98548

OOOO

1 NO + 1 NC

L/R

SL 94217

OOOO

Auxiliary contact Block

Trip Alarm contact #

2 NO + 2 NC

Factory assembled

DTH 250/400/630/800
Shunt Release

Under Voltage Release

Auxiliary contact Block


Trip Alarm contact #

Factory assembled

Rotary operating mechanism

ROM

SL 94337

OOOO

Earth Fault module 1)

GF11

ST 28594

OOOO

Note :

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
24 V, 48 V, 110 V & 220 V DC are also available on request
#
On request.
1) Dimension and wiring diagram on pages 2/80 & 2/81
2/50

ACCESSORIES - ORDERING DATA


TYPE DX (100/125/160/200/250)S / DX(100/125/160/200/250)H ... (3/4 POLE)

Accessory

Shunt Release

Under Voltage Release

Auxiliary contact Block

Door coupling rotary handle

Type

Std. Pack

Catalgoue No.

Ordering
Suffix

415 V AC/DC
240 V AC/DC
110 V AC/DC
48 V AC/DC
24 V AC/DC
With early-make auxiliary contacts

1
1
1
1
1
1

ST 33007
ST 33006
ST 33005
ST 33004
ST 33003

OOOO
OOOO
OOOO
OOOO
OOOO

440 V AC

ST 33010

OOOO

415 V AC

ST 33009

OOOO

240 V AC

ST 33008

OOOO

Off-delayed

With early-make auxiliary contacts

NO

ST 33001

OOOO

NC

ST 33002

OOOO

Early make

Trip indicating

ST 33021

OOOO

ROM

ST 33016

OOOO

Toggle to rotary convert

ST 33017

OOOO

Extension shaft

ST 33018

OOOO

ST 33013

OOOO

Residual-current protection module

Paralleling mechanism

Mechanical interlock

Plug-in adaptor

Side wall operator

Remote operator

240 V AC

Note: ROM consists of (Door coupling rotary handle + Toggle to rotary convert + Extension shaft)

2/51

ACCESSORIES - ORDERING DATA


TYPE DX (400/630)S / DX(400/630)H ... (3/4 POLE)
Accessory

Time selectivity block

Shunt Release

Under Voltage Release

Auxiliary contact Block

Annunciation unit
Door coupling rotary handle

Type

Std. Pack

Catalgoue No.

Ordering
Suffix

125-250A

ST 33053

OOOO

200-400A

ST 33054

OOOO

300-630A

ST 33055

OOOO

125-250A (1000-6000)

ST 33056

OOOO

200-400A (1000-9000)

ST 33057

OOOO

300-630A (1000-9000)

ST 33058

OOOO

110 V AC/DC

ST 33034

OOOO

240 V AC / DC

ST 33035

OOOO

415 V AC / DC

ST 33036

OOOO

240 V AC

ST 33037

OOOO

415 V AC

ST 33038

OOOO

440 V AC

ST 33039

OOOO

Off-delayed (AC)

2NO + 2 NC

ST 33030

OOOO

Early make

General trip indicating

ROM

ST 33045

OOOO

Toggle to rotary convert

ST 33046

OOOO

Extension shaft

ST 33047

OOOO

Used with Rotary drive

ST 33048

OOOO

240 V AC

ST 33042

OOOO

415 V AC

ST 33043

OOOO

Rotary handle
Remote operator
Residual-current protection module

240 V AC

415 V AC

Paralleling mechanism
Mechanical interlock

For 2 MCCBs

ST 33049

OOOO

For 2 MCCBs with Remote operator

ST 33050

OOOO

For 3 MCCBs 3 & 4 Pole with Toggle or Rotary drive

ST 33051

OOOO

3 Pole

ST 33031

OOOO

4 Pole

3 Pole (230 V)

ST 33040

OOOO

3 Pole (415 V)

4 Pole (230 V)

4 Pole (415 V)

3 Pole

ST 33064

OOOO

4 Pole

ST 33063

OOOO

For connection indication

ST 33061

OOOO

To connect Earth-fault release

ST 33062

OOOO

For upto 3 Pad locks

ST 33044

OOOO

Annunciation unit
Earth-fault Release (Fitted to Breaker)
Residual-current operated relays (AC)

Withdrawable unit
Withdrawable unit auxiliary contact
Toggle switch interlock

Note: ROM consists of (Door coupling rotary handle + Toggle to rotary convert + Extension shaft)
2/52

ACCESSORIES - ORDERING DATA


TYPE DX (800/1000/1250/1600)H ... (3/4 POLE)

Accessory

Type

Std. Pack

Catalgoue No.

Ordering
Suffix

200 - 480 V AC

110 V AC

200 - 480 V AC

110 V AC

Under Voltage Release

Off-delayed (AC)

Auxiliary contact Block

2NO + 2 NC

240 V AC

200 - 240 V AC

Shunt Release

Under Voltage Release

Trip type indicator


Load monitoring
Door coupling rotary handle

Toggle to rotary convert

Extension shaft

Mechanical interlock

Earth-fault Release (Fitted to Breaker)

Remote operator

Withdrawable unit

ROM

230 V AC

800 A

1250 A

1600 A

Note: ROM consists of (Door coupling rotary handle + Toggle to rotary convert + Extension shaft)

2/53

ACCESSORIES - ORDERING DATA


TYPE DM
Accessory

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110/240/415 V AC

SL 97042

OOOO

1 NO + 1 NC

R
L

1
1

SL 97023
SL 97025

OOOO
OOOO

SL 97037

OOOO

ROM

Ext.

SL 97044

OOOO

110/240/415 V AC
24 V DC

L
L

1
1

SL 97299
SL 97299

OMOO
O4OO

Under Voltage Release

415 V AC
240 V AC

L
L

1
1

SL 97610
SL 97611

OOOO
OOOO

Auxiliary contact Block

1 NO + 1 NC

R
L

1
1

SL 97296
SL 97297

OOOO
OOOO

SL 97298

OOOO

ROM

Ext.

SL 97301

OOOO

Ext.

GF1

Ext.

ST 27745

OOOO

415 V AC/220 V DC
240 V AC/110 V DC
110 V AC

1
1
1

SL 94331
SL 94331
SL 94331

ODOO
OBOO
OAOO

415 V AC
240 V AC
110 V AC

1
1
1

SL 94332
SL 94332
SL 94332

DOOO
BOOO
AOOO

1 NO + 1 NC

R
L

1
1

SL 94330
SL 94329

OOOO
OOOO

DM 16
Shunt Release
Auxiliary contact Block
Trip Alarm contact
Rotary operating mechanism

DM 100
Shunt Release

Trip Alarm contact


Rotary operating mechanism
Spreader Links with Barrier
Earth Fault module

DM 160
Shunt Release

Under Voltage Release*

Auxiliary contact Block


Trip Alarm contact #

Rotary operating handle

ROH

Ext.

SL 94336

Factory assembled
OOOO

Earth Fault module

GF2

Ext.

ST 27746

OOOO

415 V AC/220 V DC
240 V AC/110 V DC

R/L
R/L

1
1

SL 97575
SL 97576

OOOO
OOOO

Under Voltage Release

415 V AC
240 V AC

L
L

1
1

SL 97579
SL 97580

OOOO
OOOO

Auxiliary contact Block

DM 250/400
Shunt Release

1 NO + 1 NC

L/R

SL 97573

OOOO

Trip Alarm contact

SL 97574

OOOO

Adaptor terminal (3) with shroud (1) - 1 Set


Terminal shroud
Spreader Links with Barrier

Ext.
Ext.
Ext.

1
1
1

SL 97564
SL 97563
Std. Kit

OOOO
OOOO

Rotary operating handle

ROH

Ext.

SL 97562

OOOO

Earth Fault module

GF2

Ext.

ST 27746

OOOO

Note :

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
24 V, 48 V, 110 V & 220 V DC are also available on request
#
On request.
2/54

ACCESSORIES - ORDERING DATA


TYPE DTH 800 INST.

Accessory

Shunt Release

Under Voltage Release *

Auxiliary contact Block


Rotary operating mechanism
Note :

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110 V AC

SL 98523

OOOO

415 V AC/220 V DC

SL 98526

OOOO

24 V DC

SL 98531

OOOO

240 V AC/110 V DC

SL 98534

OOOO

110 V AC

SL 98543

OOOO

240 V AC

SL 98545

OOOO

415 V AC

SL 98548

OOOO

1 NO + 1 NC

L/R

SL 94217

OOOO

ROM

Ext.

SL 94337

OOOO

Any two internal accessories can be fitted simultaneously in a breaker


R
To be mounted on right side
L
To be mounted on left side
L/R Can be mounted on either side
Ext. External
*
24 V, 48 V, 110 V & 220 V DC are also available on request

ACCESSORIES - ORDERING DATA


TYPE DF
Accessory

Shunt Release
Trip Alarm contact
Auxiliary contact Block
Note :

2/55

Any one can be used.


R
To be mounted on right side

Coil Voltage /
Type

Location

Std. Pack

Catalogue No.

Ordering
Suffix

110/240/415 V AC

SL 97042

OOOO

SL 97037

OOOO

1 NO + 1 NC

SL 97023

OOOO

OVERALL DIMENSIONS
MCCB - TYPE DS

MOUNTING AND
DOOR CUTOUT DETAILS

MOUNTING AND
DOOR CUTOUT DETAILS

DS 100

DS 125/160/200

MOUNTING AND
DOOR CUTOUT DETAILS

DS 250/400
Note: All dimensions are in mm.
2/56

OVERALL DIMENSIONS
DIMENSIONAL DETAILS OF ROTARY OPERATING MECHANISM - TYPE DS

DS 100/125/160/200

DS 250/400
Note: All dimensions are in mm.
2/57

OVERALL DIMENSIONS
MCCB - TYPE DTH..E

MOUNTING AND
DOOR CUTOUT DETAILS

DTH 200E

DTH 250/400/630/800 E

ROTARY OPERATING MECHANISM FOR TYPE DTH..E

DTH 200E

DTH 250/400/630/800 E

Note: All dimensions are in mm.


2/58

OVERALL DIMENSIONS
MCCB - TYPE DG

MOUNTING AND
DOOR CUTOUT DETAILS

DG 125/200

MOUNTING AND
DOOR CUTOUT DETAILS

DG 250/400
Note: All dimensions are in mm.
2/59

OVERALL DIMENSIONS
DIMENSIONAL DETAILS OF ROTARY OPERATING MECHANISM - TYPE DG

DG 125/200

DG 250/400

EXPLODED VIEW OF ROTARY OPERATING MECHANISM

Note: All dimensions are in mm.


2/60

OVERALL DIMENSIONS
MCCB - TYPE DH

MOUNTING AND
DOOR CUTOUT DETAILS

DH 100

MOUNTING AND
DOOR CUTOUT DETAILS

DH 125/160

MOUNTING AND
DOOR CUTOUT DETAILS

DH 200

MOUNTING AND
DOOR CUTOUT DETAILS

DH 250
Note: All dimensions are in mm.
2/61

DH 400

DH 630

OVERALL DIMENSIONS
DIMENSIONAL DETAILS OF ROTARY OPERATING MECHANISM - TYPE DH

DH 100/125/160/200

DH 250/400

DH 630
Note: All dimensions are in mm.
2/62

OVERALL DIMENSIONS
MCCB - TYPE DL

DL 100

DL 160/200

DL 250/400
Note: All dimensions are in mm.
2/63

OVERALL DIMENSIONS
DIMENSIONAL DETAILS OF ROTARY OPERATING MECHANISM - TYPE DL

DL 100

DL 160

DL 250/400
Note: All dimensions are in mm.
2/64

OVERALL DIMENSIONS
MCCB - TYPE DTH

DTH 100 3 POLE / 4 POLE

DTH 200

MOUNTING AND
DOOR CUTOUT DETAILS

DTH 250/400/630.800
Note: All dimensions are in mm.
2/65

OVERALL DIMENSIONS
ROTARY OPERATING MECHANISM FOR TYPE DTH

PANEL CUT OUT

DTH 100

DTH 200

DTH 250/400/630/800
Note: All dimensions are in mm.
2/66

OVERALL DIMENSIONS
DX 100-250 S/H ... 3/4 POLE

ROTARY DRIVE / ROTARY HANDLE FOR SURFACE MOUNTING BREAKERS


Note: All dimensions are in mm.
2/67

OVERALL DIMENSIONS
DX 100-250 S/H... 3/4 POLE

EXTENSION SHAFT

DOOR COUPLING ROTARY HANDLE FOR REAR MOUNTING SWITCHES

REMOTE OPERATOR
Note: All dimensions are in mm.
2/68

OVERALL DIMENSIONS
DX 160 S/H, DX 200-250 S/H

PLUG-IN ADAPTER
Note: All dimensions are in mm.
2/69

OVERALL DIMENSIONS
DX 400-630 S/H (3/4 POLE)

DIMENSIONAL DETAILS OF ROTARY OPERATING MECHANISM

ROTARY DRIVE

DOOR COUPLING ROTARY HANDLE


Note: All dimensions are in mm.
2/70

OVERALL DIMENSIONS
DX 400-630 S/H ... 3/4 POLE

REMOTE OPERATOR

PUSH-BUTTONS FOR REMOTE OPERATION ENCLOSED BREAKERS

WITHDRAWABLE UNIT
Note: All dimensions are in mm.
2/71

OVERALL DIMENSIONS
DX 800-1250 H ... 3/4 POLE

DX 1600 H ... 3/4 POLE

Note: All dimensions are in mm.


2/72

OVERALL DIMENSIONS
DX...H 800-1600 A (3/4 POLE)

MOUNTING BRACKETS
Note: All dimensions are in mm.
2/73

REAR CONNECTION

OVERALL DIMENSIONS
DX 800-1600 H ... 3/4 POLE

ROTARY DRIVE

DOOR COUPLING ROTARY HANDLE

REMOTE OPERATOR
Note: All dimensions are in mm.
2/74

OVERALL DIMENSIONS
DX 800-1600 H ... 3/4 POLE

WITHDRAWABLE UNIT
Note: All dimensions are in mm.
2/75

OVERALL DIMENSIONS
MCCB - TYPE DM

MOUNTING AND
DOOR CUTOUT DETAILS

DM 16

MOUNTING AND
DOOR CUTOUT DETAILS

DM 160

DM 100

MOUNTING AND
DOOR CUTOUT
DETAILS

MOUNTING AND
DOOR CUTOUT DETAILS

DM 250/400

Note: All dimensions are in mm.


2/76

OVERALL DIMENSIONS
ROTARY OPERATING MECHANISM FOR MOTOR BACK-UP PROTECTION RANGE FOR TYPE DM

DM 16

DM 100

DM 160

DM 250/400

Note: All dimensions are in mm.


2/77

OVERALL DIMENSIONS
MCCB - TYPE DTH 800 INST.

ROTARY OPERATING MECHANISM FOR DTH 800 INST.

Note: All dimensions are in mm.


2/78

OVERALL DIMENSIONS & CONNECTION DIAGRAM


FUSE MONITORING DEVICE TYPE DF

Caution : Connect terminals of DF in parallel with the fuse links.


Note: All dimensions are in mm.
2/79

OVERALL DIMENSIONS
EARTH FAULT MODULES - GF1, GF2, GF11

GF1

GF2

GF11
Note: All dimensions are in mm.
2/80

WIRING DIAGRAM
EARTH FAULT MODULES - GF1, GF2, GF11

GF1 & GF2

GF11

2/81

OVERALL DIMENSIONS
SS ENCLOSURE

Note: All dimensions are in mm.


2/82

You might also like