SANITARY SEWER PROFILE

M.H. #6 TO #4

SANITARY SEWER PROFILE


M.H. #22 TO #20

SCALE: HORZ. 1"=50'


VERT. 1"=5'

SCALE: HORZ. 1"=50'


VERT. 1"=5'

SANITARY SEWER PROFILE


M.H. #9 TO #5
SCALE: HORZ. 1"=50'
VERT. 1"=5'

SANITARY SEWER PROFILE


M.H. #40 TO #39

SANITARY SEWER PROFILE


M.H. #27 TO #26

SCALE: HORZ. 1"=50'


VERT. 1"=5'

SCALE: HORZ. 1"=50'


VERT. 1"=5'

SANITARY SEWER PROFILE


M.H. #16 TO #7
SCALE: HORZ. 1"=50'
VERT. 1"=5'

1.
All PVC SDR 35 and SDR 26 Gravity Sewer Pipe shall be manufactured from PVC compound with a cell class of
12364 and/or 12454 as per ASTM D 1784. Pipe shall be manufactured in strict compliance to ASTM D2241 with regard
to pressure rating, material workmanship, burst pressure, flattening, impact resistance and extrusion quality. PVC SDR 35 and
SDR 26 pipe shall conform to ASTM D 3034 for gasket or solvent weld pipe with a minimum pipe stiffness of 46. Pipe shall
be plastic sewer main outside diameter with a standard dimension ratio (SDR) of 35 or 26 as applicable. Gaskets shall
conform to ASTM F 477. All pipe to be installed in accordance with manufacturer's recommendations and local code
requirements. Buried pipe shall be installed in accordance with ASTM D 2321 and ASTM F 1668. Solvent cements shall
conform to ASTM D 2564, Primer shall conform to ASTM F 656.
2.
Sewer pipe installation at depths up to 12 feet shall be SDR 35. Sewer pipe installation at depths between 12 feet and
20 feet shall be SDR 26. All sewer installation deeper than 20 feet shall be Class 52 ductile iron pipe.
3.

All exissting and proposed sewers within the project are 8 inches in diameter.

SANITARY SEWER PROFILE


M.H. #45 TO #44

SANITARY SEWER PROFILE


M.H. #43 TO #42

SCALE: HORZ. 1"=50'


VERT. 1"=5'

17
IG

76
BE
F

ORE YOU

CO

20141642689

REGISTERED

No.

Date:

06/04/2015

Description:
REVISED PER TOWNSHIP ENGINEER REVIEW LETTER DATED FEBRUARY 23, 2015

PRELIMINARY
LAND DEVELOPMENT PLAN

CHARLES A. DOBSON

GRAPHIC SCALE

ENGINEER

EN

NSY L V A N

IA

Date:

1/30/2015
Scale:

AS NOTED
Drawn by:

PROFESSIONAL

PENNSYLVANIA ACT 187 REQUIREMENTS:


InLand Design, LLC does not guarantee the accuracy of the
locations f or existing subsurf ace utility structures shown on the
plans, nor does InLand Design, LLC guarantee that all
subsurf ace structures are shown. The contractor shall verif y the
location and elevation of all underground utilities and structures
before the start of work.

N W E A LT
H
MO

224

Pennsylvania One Call System


PA. act 172 of 1986 requires
three working days notice
Serial Numbers:

0-

EM
YST
LS

IA ONE CA
AN
L
LV

80
1-

UPI: 42-4-321, 42-4-321.1 & 42-4-321.2

L
CA

InLand Design, LLC expressly reserves its common law copyright and all
other proprietary rights in these plans. All drawings, specif ications and
copies thereof are and shall remain the property of InLand Design, LLC.
They are to be used only in respect to this project and are neither to be
used on any other project, nor are they to be assigned to any third party
without f irst obtaining the expressed written permission and consent of
InLand Design, LLC. Any re-use without written permission, verif ication,
consent or adaptation by InLand Design, LLC f or the specif ic purpose
intended, will be at the third party's sole risk and without liability or legal
exposure to InLand Design, LLC the third party shall f urther indemnif y
and hold harmless InLand Design, LLC f rom all claims, damages, losses,
and expenses arising thereto or resulting therefrom.

P ENN
SY

SCALE: HORZ. 1"=50'


VERT. 1"=5'

TAH
Checked by:

CAD
Project No.
( IN FEET )
1 Inch = 50'

10383

SEWER PROFILES
FOR

MALIN ROAD DEVELOPMENT


MALIN ROAD, MALVERN, PA 19355
EAST WHITELAND TOWNSHIP CHESTER COUNTY PENNSYLVANIA

S H E E T

29
OF 33