Professional Documents
Culture Documents
Tension Anchor Reinforcement: Design Satisfactory
Tension Anchor Reinforcement: Design Satisfactory
Input Data:
Req'd Anchor Reinf. Strength, N =
Number of Vert. Reinf., Nr =
Estimated Embedment, hef =
Anchor Reinforcement Size =
Reinforcing Yield Strength, fy =
Concrete Comp. Strength, f 'c =
Lightweight Concrete?
Epoxy Coated Bars?
Ratio: As(required)/As(provided) =
Seismic Design per Chapter 21?
Center-to-Center Bar Spacing, bs =
Clear Cover to Face of Bar, bc =
Bolt-Reinf. Distance, d =
35
4
14
4
60
4.0
No
No
0.74
No
12.00
2.00
6.00
kips
in.
(dia. = 0.5'')
ksi
ksi
bs
d
in.
in.
in.
DESIGN SATISFACTORY
bc
Results:
Development Length (Section 12.2 or 21.7.5):
Ld =
17.6
in.
Ldh =
7.0
in.
Required Anchor Embedment:
hef,min =
13.22 in.
hef,prov =
14.0
hef,min = Ldh+bc+0.7*d
in.
0.79
in
Note: In situations where the edge distance, from centerline of bolts to edge of concrete, is less than 1.5 times
the embedment depth, it is recommended that containment steel, such as stirrups, be used.
Comments:
C:\Users\yba\Downloads\ANCHORBOLT(318-08)
1 of 1