TENSION ANCHOR REINFORCEMENT

Per Building Code Requirements for Structural Concrete ( ACI 318-08)


Job Name:
Job Number:

Design of Anchor Reinforcement in place of Concrete Breakout Strength


Subject: xyz baseplate
Date:
7/29/2015 12:34
Originator:
Checker:

Input Data:
Req'd Anchor Reinf. Strength, N =
Number of Vert. Reinf., Nr =
Estimated Embedment, hef =
Anchor Reinforcement Size =
Reinforcing Yield Strength, fy =
Concrete Comp. Strength, f 'c =
Lightweight Concrete?
Epoxy Coated Bars?
Ratio: As(required)/As(provided) =
Seismic Design per Chapter 21?
Center-to-Center Bar Spacing, bs =
Clear Cover to Face of Bar, bc =
Bolt-Reinf. Distance, d =

35
4
14
4
60
4.0
No
No
0.74
No
12.00
2.00
6.00

kips
in.
(dia. = 0.5'')

ksi
ksi

bs
d
in.
in.
in.

DESIGN SATISFACTORY
bc

Results:
Development Length (Section 12.2 or 21.7.5):
Ld =
17.6
in.
Ldh =
7.0
in.
Required Anchor Embedment:
hef,min =
13.22 in.
hef,prov =

14.0

hef,min = Ldh+bc+0.7*d

in.

Anchor Reinforcement Strength(Section D.5.2.9):


2
in
As,min =
As,min = N/(0.75*fy)
0.78
As,prov =

0.79

in

Note: In situations where the edge distance, from centerline of bolts to edge of concrete, is less than 1.5 times
the embedment depth, it is recommended that containment steel, such as stirrups, be used.

Comments:

C:\Users\yba\Downloads\ANCHORBOLT(318-08)

1 of 1