SPESIFIKASI

PEMBANGKIT DAYA
Pembangkit Daya Tenaga Kincir Angin

Specification
Rotor

Diameter

80m

Swept area

4,978m2

Rotor location

Downwind

Rotational speed

11.119.6min-1

Rated rotational
speed

17.5min-1

Rotational direction Clockwise (from upwind)


Tilting angle

-8

Blade

Coning angle

Quantity

3 pcs

Length

39m

Material

GFRP (glass-fiber reinforced resin)

Structure

1 planetary gear, 2 parallel gears

Gearbox
Gear ratio

nearly 1:100 (50Hz)


nearly 1:120 (60Hz)

Generating system DFIG (doubly fed induction generator)

Generating
system

Rated generator
output

2,000kW

Generator voltage

1,400V

Generator current

825 A

Number of
generator poles

4 poles

Rated generator
speed

1,736min-1 (50Hz)

Generator power
factor

100% (operation range: delay 90% to


advance 95%)

2,098min-1 (60Hz)

PCS cooling system Antifreeze circulation, wind-cooled


PCS control system Active power control
Capacity

2,222kVA

Transformer system Oil-immersed self-cooled


Incorporationtype
Voltage
transformer

Nacelle

Tower

22kV/1.4kV (Except 22kV series, the set-up


transformer, panels, auxiliaries, etc. are
placed outside of the tower)

Winding
configuration

Material

GFRP (glass-fiber reinforced resin)

Dimensions

L11.5m/ W3.5m / H4.9m(H excludes the


sensor mast.)

Tower system

Steel monopole

Anchor system

Steel monopole (anchor ring)

Hub height

65m / 78m

Number of divisions 3 (65cm) / 4 (78cm)


Output control

Pitch, variable velocity

Cutin wind velocity 4m/s

System

Cutout wind
velocity

25m/s

Maximum wind
velocity

70m/s(3 seconds)50m/s(10 minutes


average)

Emergency brake

Blade feather (independent pitch)

Maintenance brake Disc brake


Yaw control

Active yaw

Standby for storm


wind

Free yaw

Lightning strength

250kA(peak current)
600C(total charge)

IIA+ (standard) (Provided that the IA type is


Wind velocity class possible depending on the wind velocity class
of the tower)
lEC disturbance
Environmental strength
conditions
Operation
temperature

A
-20 to 40

Noise power level

103.8dBA

Altitude