Power Transmission Hardware Configuration: Site Down Case

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

Site Down Case

Power
Transmission
Hardware
Configuration

Command logs need to add in work info tab of TT


ZEOL:<BCFID>;
ZAHO:ET,<PCM ID>;
ZYEF:ET,<PCM ID>;

Comments need to add in TT (Automated Notes)


Site down with power alarms ( MAINS FAIL, MODULE RECT FAIL ), FE need to check Power at the
site
Site down with Transmission alarms (PCM FAILURE, BCCH MISSING), Suspect transmission issue. FE
need to check the transmission cables, configuration, link at the site
Site down with Hardware faulty alarms at the site (TRE faulty) , Suspects Hardware issue. FE needs
to check BTS H/W, Tx H/W, Cables & antennas at the site
Site down with Configuration issue alarm (Configuration of BCF failed), Suspect configuration issue.
BO need to check the configuration of the site & engage FE if required

d logs need to add in work info tab of TT

<PCM ID>;
<PCM ID>;

Alarms

Action Team

MAINS FAIL, MODULE RECT FAIL

FE

PCM FAILURE, BCCH MISSING

FE

TRE faulty

FE

Configuration of BCF failed

BO/ FE

Commands Used for the FTR:


ZEEI:BCF=<BCFID>; To check the site status
ZEOL:<BCFID>; To check the alarm at the site
ZAHO:ET,<PCM ID>; To check the ET alarms
ZYEF:ET,<PCM ID>; To check the ET alarms
ZUSI:ET, <PCM ID>; To check the ET status
ZUSC:ET, <PCM ID>:BL; To block the ET
ZUSC:ET, <PCM ID>:WO; To activate the ET

* Need to fill the RED color alarm tab only

D color alarm tab only