Punching Shear Design: Default Example: Input Data

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Job Number

Sheet

Job Title
Software Consultants (Pty) Ltd
Internet: http://www.prokon.com
E-Mail : mail@prokon.com

Client
Calcs by

Checked by

Date

C23

Punching Shear Design : Default Example


Input Data
Column width A

(mm) 600

Column breadth B

(mm) 250

Effective slab depth deff

(mm) 367

Nearest edge X-direction

(mm) 1500

Nearest edge Y-direction

(mm) 1500

fcu

(MPa) 35

fy flexural reinforcement

(MPa) 460

fyv shear reinforcement

(MPa) 460

X-reinforcement crossing perimeter 1

4900

Perimeter 2

(mm) 4900

Perimeter 3

(mm) 4900

Perimeter 4

(mm) 4900

Y-reinforcement crossing perimeter 1

4900

Perimeter 2

(mm) 4900

Perimeter 3

(mm) 4900

Perimeter 4

(mm) 4900

Shear head present

(Y/[N])

Max. link/tie size

(mm)

Load Cases

Description

DL

ULS
Shear Vt
(kN)

665

ULS
X-moment
(kNm)

-55

ULS
Y-moment
(kNm)

18.4

BS8110 - 1997

Mty
Y

Load
Case

550.50

Mtx
X

825.75
1101.00
1376.25

Job Number

Sheet

Job Title
Software Consultants (Pty) Ltd
Internet: http://www.prokon.com
E-Mail : mail@prokon.com

Client
Calcs by

Checked by

Date

Output for Load Case 1:DL


Critical load case: 1:DL
Perimeter
Distance from
(mm)
Column face

550

826

1101

1376

Critical length

(mm)

4526

5076

5627

6178

Allowable shear stress


(MPa)
vc

0.61

0.58

0.56

0.55

Shear force capacity


Vc

(kN)

1006

1086

1163

1238

Effective shear force


Veff

(kN)

831

831

831

831

Total reqd. reinforcement


(mm)
Asv

Load Case 1:DL


2
3

Suggested
reinforcement
configurations

Shear reinforment should be placed in a band 1.5*d wide


inside each critical perimeter. Maximum spacing 0.75*d.
Reinforcement given for entire failure zone - user should adjust for shared reinforcement.
v at column face =1.07 MPa <= vcu = 4.73 MPa