Professional Documents
Culture Documents
Wall Thickness Tyo
Wall Thickness Tyo
Wall Thickness Tyo
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
oil
g
sw
Value
500
?
1
3
0.50%
210000
0.3
450
535
420
515
15%
YES
120
30
150
200
1.1
1.5
800
9.81
1025
100
Unit
mm
mm
Mpa
Mpa
Mpa
Mpa (100C)
Mpa (100C)
barg @ 30m
m
m
m
m
kg/m
m/s
kg/m
C
SOLUTION
DESIGN PARAMETER
Location
Fluid Type
Safety class
Safety class resistance factor (gsc)
Incidental Factor (ginc)
Material Resistance Factor (gm)
Stress De-Rating
spt
=
=
=
=
=
=
=
=
1
B
Medium
1.138
1.1
1.15
30
Mpa
1.05
fy =
fu =
420 Mpa
505 Mpa
OD =
0.5
Pinc =
13200000 Pa
Pli =
14612640 Pa
Plt =
15343272 Pa
Pe =
1493205 Pa
Pli-Pe =
Plt - Pe =
13.119 Mpa
13.850 Mpa
fcb1 =
fcb2 =
420 Mpa
439.130 Mpa
t1 burst =
=
0.009 m
8.697 mm
t =
tnom =
9.697 mm
12.697 mm
(minimum)
t1 =
=
0.0091722 m
9.1721787 mm
tnom =
=
13.17 mm
0.01317 m
wall thickness =
14.3 mm
SMYS*0,96
SMTS*0,84
=
=
432 Mpa
449.4 Mpa
Ph
=
=
23.3774 Mpa
233.7739 Barg
Mill P Test
214.8657 Barg
Pt
=
=
13.11943538 Mpa
131.2 Barg