Mechanical Ventilation N: Ventilation Systems General Notes

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

VENTILATION SYSTEMS

GENERAL NOTES

THERE ARE THREE WAYS OF ARTIFICIAL VENTILATION SYSTEMS.


1). PLENUM SYSTEM: IN THIS METHOD, AIR IS FORCED TO COME IN THROUGH A MECHANICAL FAN BUT THE EXIT IS NATURAL.
ITS DONE IN PLACES WITH HUGE VOLUMES SUCH AS BASEMENT, FACTORIES ETC

DUCT WORK:
- DUCT WORK MUST BE PERMANANT,
RIGID, NON BUCKLING AND NON
RATTLING.

2). EXTRACT SYSTEM: IN THIS METHOD, AIR ENTERS NATURALY, BUT IT IS TAKEN OUT BY MECHANICAL MEANS, SUCH AS
EXHAUST FANS.
3). PLENUM AND EXTRACT SYSTEM: IN THIS METHOD, MECHANICAL SYSTEM IS USED FOR BOTH PLENUM AND EXTRACT.
THIS IS TYPICALLY USED IN PARKING LOTS
COMMERCIAL KITCHENS, PETROCHEMICAL LABORATORIES AND WAREHOUSES.
FOR SUCH CASES, FAN ROOMS ARE REQUIRED.

- JOINTS IN DUCT WORK ARE AIR


TIGHT.

THE SYSTEM USED FOR THIS DESIGN OF BASEMENT IS PLENUM AND EXTRACT SYSTEM.

- GALVANISED IRON OR ALUMINIUM


SHEETS ARE USUALLY USED IN THE
CONSTRUCTION OF DUCTS.

CENTRIFUGAL FAN
EXTRACTION DUCT

CENTRIFUGAL FAN
FRESH AIR INLET DUCT
( PLENUM DUCT )

1.2 M

4M
PARKING

EXHAUST ROOM

MECHANICAL VENTILATION

- THE DUCT WORK SHALL SURELY BE


PROTECTED BY METAL HANGERS,
STRAPS OR BRACKETS.

PLENUM ROOM

SECTION AA'
SCALE- 1:200

- SUPPLY DUCTS SHALL BE


EQUIPPED WITH AN ADJUSTABLE
LOCKING TYPE DAMPER TO
CONTROL THE AIR VOLUME.

R.C.C. SLAB

G.L.
1.2 M

R.C.C. BEAM

4M
0.45 M

DRIVEWAY

PARKING

G.I. HANGERS TO
SUPPORT DUCTS

DRIVEWAY

SECTION AA'

G. I. DUCT

SCALE- 1:200
WET RISER DUCT

C:\4th yr acads\services\dwi services\servives final\centrifugal-fans.jpg

CROSS MARKINGS MADE


TO RESIST VIBRATION OF
MOVING AIR

DUCT FOR
SPRINKLER MAIN PIPE

STEEL SECTION

EXHAUST
ROOM

- THE DAMPER SHOULD BE


INSTALLED IN THE SUPPLY DUCT AS
FAR AS POSSIBLE FROM THE
OUTLET.

LEGEND

UP

HANGING OF DUCTS FROM CEILING

AXIAL FAN

CENTRIFUGAL FAN

RETURN AIR DUCT


( EXTRACTION DUCT )

A'

UP

FRESH AIR INLET


( PLENUM DUCT )

FRESH AIR DIFFUSER


DRIVEWAY

PARKING

EXHAUST DOWNCOMER
DUCT

AC PLANT
ROOM

PARKING

R.C.C. COLUMN
DRIVEWAY

EXTRACT / OUTLET DUCT


(300 x 300 MIN)
CROSSINGS MADE IN DUCT
TO RESIST VIBRATION
FIXING MEMBERS

- 2.8 M

FIRE
FIGHTING
ROOM

UP

LOWER PORTION OF DUCT BENT


FOR EXTRACTION
WITH CARBON FILTER

PLENUM
ROOM

0.45 M

DOWN

RAMP

B'
BASEMENT LAYOUT

DOWNCOMER DUCT
OF EXTRACTION

FIXING OF DUCT TO WALL / COLUMN

SCALE- 1:200

MECHANICAL VENTILATION
PROJECT: COMMERCIAL COMPLEX AT BANDRA