Service Manual BML Myanmar PT.

Hartono Istana Teknologi

- Adjust R & G DC, to get standard value : x = 264 ± 7 xy ≤ 5


y = 256 ± 7
} Minolta
Y = 1.8 s/d 5 CA-100

- Press menu button to save data Adjustment.


- Change its probe to the white one.
- Adjust R gain, G Gain to get standard value : x = 264 ± 5
y = 266 ± 5
} Minolta
CA-100+
- Press menu button to save data Adjustment.
- Check again if low bright value has non standard value.
- Repeate same steps to make correction.
- Check High Bright once again and make correction if its value isn’t conforming, until we got
Low Bright and High Bright value according by standard value.

2. APR Adjustment :
- Acces to service mode.
- Set APR to position : - 20" = 07 (Domestic & Export)
- 21" & 21" RF = 07 (Domestic)
- 21" & 21" RF = 15 (Export)
- Press menu button to save data Adjustment.

3. Normalisation Setting (memory setting) :


- Brightness = 60 - Tint = 00
- Contrast = 100 - PNR = OFF
- Color = 60 - Pic Improve = ON
- Sharpness = 75