VeraCalc

Flow Calculation
Model No.:
Serial No.:

V510 (42 in SCH STD)


-20-H-R-F1215C-C2NS-XX
Q296384-01

Version: VWI-CS-018-REV 6.4.13

Customer:

MEDIDORES

Customer PO:

Ciro Cruz Cruz

Processed By:

Jerry Gallo

Tag No.:

Tanque Providencia

Veris Ref.:

Pipe Size:

42 in SCH STD
ID = 41.25 Wall = 0.375

Process Date:

06-08-2015 10:14:16

File Name:

Q296384-01.vfc

Water

Fluid Name:

Process:

I. Flow Equation

Water

II. Constants

Actual Volumetric Flow Rate for Liquids

Term

Description
Numeric Constant
Flow Coefficient
Pipe ID
Atmos Pressure

N
K
D
Pa

Value

Units

0.0709323
0.7792
41.25
14.70

in
psi

III. Flow Rate and Differential Pressure


Term

Description

Maximum

Nominal

Minimum

Units

2500

2000

400

liter/sec

94.0411

94.0411

94.0411

Qv

Actual Volumetric Flow Rate

C'

Flow Constant

Pf

Flowing Pressure

kg/cm^2 G

Tf

Flowing Temperature

18

18

18

Gf

Flowing Specific Gravity

S.G. @flow

Fa

Thermal Expansion Factor

1.000

1.000

1.000

hw

Differential Pressure

706.715

452.298

18.092

mm H2O(20C)

IV. Structural Limits


Term

ANSI Eq

at User's Maximum

Ultimate Maximum

Limiting Component at Ultimate

Max Temp

N/A

427 C at 98 Kpa G

427 C at 552 Kpa G

Instr. Valve

Max Press

ANSI 150

1896 Kpa G at 18 C

1896 Kpa G at 38 C

Sensor Flange

Maximum Allowable Flow Rate at Maximum Column:


Maximum Insert/Retract Flow Rate at Maximum Column:

4537.909 liter/sec (2328.498 mm H2O(20C))