Tecsis Data Sheet Ae513

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

| Force | Pressure | Temperature | Switch

Handpump with fine adjustment


Model:
or

Pressure 0 ... 16 bar


Vacuum -780 ... 0 mbar

Description

Features

The hand pump with fine adjustment is a pneumatic

o High reliability and life span

compression device for a pressure output from 0 to 16 bar and


is operable by hand. The hand pump is especially suitable to

o Simple operation

check or to calibrate pressure measuring instruments, as for

o High-quality materials

example load cells, pressure sensors and gauges. The pump is

o Fine adjustment

portable because of its compact construction and is to serve


handily and easily. A fine automatic controller at the pump
enables a fine regulation of the pressure output. The pressure
pump was developed for a fast and simple pressure calibration.

Work principle and construction


The hand pump consists of a cylinder, a piston, a pressure
release valve, a fine adjustment and the handles. Over the two

Ranges
-780 ... 0 mbar

Article no. C1351X085003

0 ... 16 bar

Article no. C1351X085001

Technical Data
o Initial pressure: 0 to 16 bar or
-780 to 0 mbar

available internal threads the pump can be attached to the test


normal and the test sample, in order to check or calibrate. The

o Ambient:
Temperature: -20 to 50 C

handles have to be pressed and released by hand a few times.

Relative air humidity: < 100%

As result an initial pressure within an area from 0 to 16 bar or -

o Connection for hose connector

780 to 0 mbar is produced.

Female thread: 1/4 NPT


o Connection for test normal

Operation

female thread: 1/4 NPT

o Connect test normal and the instrument which is

o Dimensions: 230 x 110 x 60

supposed to be calibrated with the pump by using

o Weight:

the flexible hose and the supplied connections.

o Accessories: pressure gauge, carrying

o During inflating you close the opening valve in

0.5 kg

suit case, tube: length appr. 500 mm

clockwise direction. For pressure relief you turn the

1 x female thread, 1 x male thread 1/4 NPT

opening valve against clockwise direction.


o Before the calibration of the pressure measuring
device each connection should be checked for

Application

tightness. After the calibration make sure that the

Calibration and check of pressure gauges,

pressure is relieved before unscrewing the

in laboratory and research establishment.

instrument. (otherwise danger of injury exists).


Model: C1351X085XXX

Modifications reserved
tecsis GmbH
Carl-Legien Str. 40
D-63073 Offenbach / Main
Tel.: +49 69 5806-0

AE 513 a
Sales national
Fax: +49 69 5806-170

Sales international
Fax: +49 69 5806-177

e-Mail: info@tecsis.de
Internet: www.tecsis.de

p. 1 / 1