Notes:

All dimensions are in metric.


All steel grade S275 U.N.O.
All welds 6mm FPFW U.N.O.
All bolts grade 8.8 U.N.O.

14 HOLES THROUGH
FOR M12 BOLTS TO
TIMBER BY OTHERS.

40

PLT12*200

160

ANCON 25/14
CHANNEL.

10

100

SH
S1
0

55 )

S3
.0 (
6
*
0
*10

00

1-No. FOR HOUSE TYPE 9


(PLOT 101)

CF-SHS100*100*6.0 ( S355 )

0*

60

1
SHS
CF-

4-No. FOR HOUSE TYPE 10


(PLOTS 38, 47, 99, 100)
302

3-No. FOR HOUSE TYPE 13


(PLOTS 59, 94, 103)

5
(S
35
6.

ANCON 25/14
CHANNEL.

0*

SH
S1
0

0*

10

3-No. FOR HOUSE TYPE 14


(PLOTS 35, 36, 98)

FIRST FLOOR PLAN

1054

C
F-

5-No. FOR HOUSE TYPE 17


(PLOTS 48, 49, 50, 96, 97)

GROUND FLOOR PLAN


PLOTS 33, 36, 38, 48, 58, 94, 95, 97, 98, 99, 100, 102

C
1

CF-SHS100*100*6.0 ( S355 )

C
2

300

10

2-No. M12 SPIT


EPOMAX RESIN
ANCHORS.

2-No. M12 SPIT


EPOMAX RESIN
ANCHORS.

REFER TO ARCHITECTS
DRAWINGS FOR FRAME
SETTING OUT.

300

10

302

10

10

60

60

C
F-

115

235

235

115
100

215

60

0*

PLT12*200

40

6.

160

ANCON 25/14
CHANNEL.

(S
35

200

Finish:
Primer Painted

CF-SHS100*100*6.0 ( S355 )

200

22-No. BUTTRESS FRAMES


REQUIRED IN TOTAL
(NOTE HANDING SHOWN
ON PLAN VIEWS).

1-No. FOR HOUSE TYPE 18


(PLOT 95)
DET 1

3-No. FOR HOUSE TYPE 19


(PLOTS 57, 93, 102)

DET 1

2-No. FOR HOUSE TYPE 20


(PLOTS 58, 33)

100

73

+1st FFL

ANCON PP25-125
BRICK TIES SUPPLIED
WITH DE-BONDING
SLEEVES.

CF-SHS100*100*6.0 ( S355 )

.0
*6
00
*1
00

F-

SH

ANCON 25/14
CHANNEL.

10

SH
C
4

115
60

235

235

115
60

215

F-

10

60

100

60

S1

10

C
3

10

2-No. M12 SPIT


EPOMAX RESIN
ANCHORS.

2-No. M12 SPIT


EPOMAX RESIN
ANCHORS.

(S

35

1054

S1

REFER TO ARCHITECTS
DRAWINGS FOR FRAME
SETTING OUT.

00

*1

00

*6

.0

(S

35

ANCON PP25-125
BRICK TIES SUPPLIED.

A
40

ANCON 25/14
CHANNEL.

PLT12*200

PLT12*200

200

200

PADS CAST IN
BY OTHERS.

2650 - ANCON

GROUND FLOOR PLAN


PLOT 101
ANCON CHANNELS
FIXED TO COLUMNS
WITH TEK-SCREWS
AT 450mm CENTRES.

2890

160

160

2565

ANCON 25/14
CHANNEL.

40

225 TYP.

ISSUED FOR APPROVAL

P1
P2

16.9.13
27.9.13

C1

LEVELS, SETTING OUT REVISED


REVISED & ISSUED FOR CONSTRUCTION

14.10.13

REVISION

DESCRIPTION

DATE

maldon marine ltd.

BEAM & BLOCK FLOOR.

ENGINEERS AND CONTRACTORS


Design, Fabrication and Erection of Steelwork.
Unit 16
West Station Industrial Estate
Spital Road
Maldon, Essex
CM9 6TW

SH
FC

F-

ANCON 25/14
CHANNEL.

225
12

GAP FOR SOLID


PACKS & GROUT.

CLAY FARM PHASE 3

1a

JOB DESCRIPTION:

CF-SHS100*100*6.0 ( S355 )

SUPPLY AND FIX BUTTRESS FRAMES TO

DETAIL 1

HOUSE TYPES 9, 10, 13, 14, 17, 18

15

10

SITE NAME:

DRAWING STATUS:

CONSTRUCTION

C
4

1054

COUNTRYSIDE PROPERTIES

1a
B

REFER TO ARCHITECTS
DRAWINGS FOR FRAME
SETTING OUT.

ANCON 25/14
CHANNEL.

260
160

GROUND FLOOR PLAN


PLOTS 35, 47, 49, 50, 57, 59, 93, 96, 103

50

DRAWN BY:

50

SCALE :

120

16.09.2013

TITLE:

GA & DETAILS OF BUTTRESS FRAMES

10

60

FS
DATE DRAWN:

NTS

60
Tekla Structures

PDF created with pdfFactory trial version www.pdffactory.com

CHECKED BY:

MB

PLT10*120

A - A
SECTION B-B OPPOSITE HAND

+44 (0) 1621 859000


+44 (0) 1621 858935
info@maldon-marine.co.uk
www.maldon-marine.co.uk

CLIENT:

10

215
10

60

60
10

2-No. M12 SPIT


EPOMAX RESIN
ANCHORS.

2-No. M12 SPIT


EPOMAX RESIN
ANCHORS.

CF-SHS100*100*6.0 ( S355 )

100

115

235

235

C
3

60

60
115

)
5
35
0

(S

10

SH

S1

00
*

10
0

*6
.

+1st FFL

Telephone:
Fax:
E-mail:
Web:

100

.0
0*
6

160

50

40

12

PLT12*200

*1
0

40

S1

160

00

ANCON 25/14
CHANNEL.

200

15

200

CF-SHS100*100*6.0 ( S355 )

(S

35
5

CF-SHS100*100*6.0 ( S355 )

3d VIEW OF TYPICAL BUTTRESS FRAME

10

1a - 1a

2-No. M12
LINDAPTER
HOLLO-BOLTS
IN 21 HOLES.

DRAWING NUMBER:

1860-001

REVISION:

C1