Dual-Band Combiner

790 862 MHz

880 960 MHz

DD (Digital Dividend) / CDMA 800

GSM 900

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or
in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Available as a single unit, or for XPol antennas
as a double unit
Built-in lightning protection
External DC stop available as an accessory

790 862

Port 3

Port 1

Port 2

782 10970, 782 10972


Single Unit

880 960

782 10971, 782 10973


Double Unit

790 862

880 960

Technical Data
Type No.

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Dimensions (w x h x d)

236

782 10970

782 10972

Single Unit

Single Unit

782 10971

782 10973

Double Unit

Double Unit
790 862 MHz
880 960 MHz

< 0.4 dB, typically 0.2 dB (790 862 MHz)


< 0.4 dB, typically 0.2 dB (880 960 MHz)
> 50 dB (790 862 MHz / 880 960 MHz)
< 1.2 (790 862 / 880 960 MHz)
50
< 200 W / < 200 W
< 160 dBc (3 rd order; with 2 x 20 W)
40 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

Stop
By-pass (max. 2500 mA)

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set
Single Unit: Approx. 3.2 kg / Double Unit: Approx. 6.1 kg
Single Unit: 175 x 51 x 207 mm / Double Unit: 175 x 106 x 207 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
790 862 MHz

880 960 MHz

DD (Digital Dividend) / CDMA 800

GSM 900

Accessories (order separately)


Clamp set
suitable for mast
diameter of

Diagram I

Clamp Set
0

734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

50

734 365

45 125 mm

60

Type No.

Description

793 301

DC stop

DC stop

10
20
880 960

790 862
30
40

70

50- load

80
90

50- load
1.5 W / indoor or outdoor

100
780

800

820

840

860

880

900

920

940

960

980

Frequency/MHz

Diagram II
Port 2 Port 3

Port 1 Port 3

Attenuation/dB

784 10367

Port 2 Port 3

Port 1 Port 3

Attenuation/dB

Type No.

Calculated Attenuation Curves

Side view
Single Unit

0
0.5
1.0
880 960

790 862
1.5
2.0
2.5
3.0
3.5
4.0

Side view
Double Unit

4.5
5.0
780

800

820

840

860

880

900

920

940

960

980

Frequency/MHz

Top view
Single Unit,
Double Unit

Please note:

3
Bottom view
Single Unit,
Double Unit

The mounting plates can be removed by loosening the


screws 1 to 4 (M5 x 12) and replaced with other
means of mounting, always provided that the max.
drilled depth of 7.5 mm is respected with the choice of
replacement screws.

237

You might also like