2.
13.5
(Page 136)
3.
15.2.6.1 (4)
(Page 159)
4.
15.11
VEdi VRdi
vEdi vRdi
Requirements given in this Clause are in Requirements given in this Clause are in
addition to those given in Clause 16.11
addition to those given in Clause 16.14
When large bars are used, adequate crack
control shall be ensured either by using
surface reinforcement as per Clause
16.2.4.2, or by calculation as per Section
12.
5.
16.7.1 (3)
(Page 185)
ac < 0.5 hc
ac 0.5 hc
16.7.1 (4)
(Page 185)
16.7.1 (4)
(Page 185)
Eq. 16.12
6.
fctd (t) is the design tensile strength at time fctd (t) is the design tensile strength at time
of release t (Refer Clause 6.4.3.3) taken of release t (Refer Clause 6.4.2.3) taken
as 0.7 ftm (t)/c
as 0.7 fctm (t)/c
IR
(Page 166)
Read
1.
For
Annexure A2 1.
Clause A2.9
Fig A2-4
Strength
Figure A2-4 2.
nfcd
Rectangular
Tensile 1.
2.
Stress
(Page 243)
7.
(Page 186)
108
ac
Note :
ac
IR
As Amended:
Note :
Provide chamfer to avoid re-entrant corners in 16.7a), 16.7 b) and 16.7 c).
Fig. 16.7 Reinforcement of a Corbel
109