Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

DESIGN CALCULATION FOR ANCHOR BOLTS

GIVEN DATA :
A

FOR GRC PANEL 6

1
2

GRC Unit Weight =


2000 Kg/M
GRC Panel Screen Dimension
a)
Height =
2400 mm
Width =
1535 mm
Thickness =
25 mm
GRC Volume =
L x W x Thk
2400 x 1535 x 25
GRC Volume = Vol=
92100000 mm
or Vol =
0.0921 m
GRC Weight = WT.= GRC Unit Weight x Volume
WT. =
2000 x
0.0921
184.20 Kg x 9.81
1807.002 N
say WT. =
1850 N
GRC Border Size
Thickness
0.04 m
Length
2.4 m
Width
0.085 m
Weight og GRC Border
16.32 Kg
Total no borders
4
Total Weight
65.28 Kg
652.8 N

FOR STEEL
1

Yield Stress Fy =

2
3

Unit Weight =
Allowable Stresses
Shear Stress ( Fv )
Bending ( Fb)
Deflection ( def )

0.4Fy
0.66Fy
L
240
E (Modulus Of Elasticity) =

275 MPa or N/mm


40000 psi
7850 Kg/M

Ga = 40
( galvanized)

since Fy < 65000 psi


for none structural member
200000 MPa or N/mm

ANALYSIS OF BOLTS
LOADS CONSIDERED:

Dead Load

2502.8 N

WIND LOAD
Building Dimension
H=

12 m

Height of the structure

D=

29 m

Greater horizontal dimension

W=
23 m
Standard Wind Speed
Vb =
45 m/s
Z=
12 m
I=
1.15
=
11.50
Zg =
12
Kzt =

1.0

Kd =

0.85

Lesser horizontal dimension

Max. Height of the structure


Building Importance - see table 6-1 page 73
Max. Height of GRC arch to install

topographic effects of 6.5.7 (Flat) see also


Figure 6.4, page 47
Directional factor see table 6.4 page 76

Kz =

1.38
qh = (0.613.Kz.Kzt.Kd.Vb.I)
qh =
1.67 KN/m
Wind load on the panel

Velocity Pressure Coefficient


Eqn 6-15, page 31
6.159863766 KN
6159.863766 N

Total Load 8662.663766 N


These load is sharing by 8 no. M8 bolts.
Load on each bolt 1082.832971 N

Shear Carrying capacity of M8 Bolt

4300

HENSE SAFE

CONCLUSION
So, provide M8 Bolts at all Connection Points
as shown in Diagram
For all other GRC screens this is the big panel.so, provide 8M GRADED BOLTS for all panels

( galvanized)

OLTS for all panels

You might also like