Professional Documents
Culture Documents
Gamma Ray Qualification
Gamma Ray Qualification
I.
SPECIFICATION:
API 1104
MATERIAL:
API 5LX 65
PIPE SIZE:
36" nominal
WALL THICKNESS:
A.
Radiation Source
1.
Type of Source
Gamma Ray:
2.
Type of Equipment
Internal:
B.
Intensifying Screens
.938 W.T.
1.
C.
D.
2.
Film
1.
2.
3.
Type of Screens:
Thickness:
Placement:
Lead
0.005"
Front and Rear
Film Type:
Number in Cassette:
How Film is Viewed
Agfa D4
One
Dry
Exposure Geometry
1.
Method:
2.
Focal Spot Size:
3.
Source-Film Distance:
4.
Object Film Distance:
5.
Radiation Angle to Object:
6.
Heat Shield:
7.
No. Exposures per Weld:
8.
Geometric Unsharpness
9.
Density
10.
Sensitivity
SWE/SWV
.153
18"
.938 "
90 degrees
N/A
One
0.008"
2.0- 4.0
Film Side 2%
source side 2%
Table 1:- Parameters for Gamma Ray Radiographic Qualification Of 36 " Diameter Butt weld
E.
Exposure Conditions
1.
Milliamperes:
Time:
N/A
2.
F.
G.
Curies:
Time:
Processing
46 ci
6min 36 sec.
1.
Automatic:
Manual:
(check one)
Automatic
2.
Development:
3.
4.
Time:
Temperature:
N/A
Penetrameters
1.
Type:
2.
Identifying No.:
3.
Material:
Steel
4.
Geometric Unsharpness:
5.
Sensitivity to be Achieved:
2.0% or better
6.
Placement:
1 penetrameters on centre of
each film
Density Range