Recommendations:: Centre For Vibration and Condition Monitoring
Recommendations:: Centre For Vibration and Condition Monitoring
(DNPER)
Recommendations:
3. Detailed analysis of the data reveals that no mechanical fault is present in the equipment and the
equipment is available for unrestricted long term operation.
4. Belt tension may be checked and relaxed upto the limit.
5. Pulley alignment (Engine-Idler-Fan) may be refined.
Note:
Broken fan blade was taken out from PPL to diagnose the root cause of blade failure. For the purpose, the
blade has been sent to Fracture Analysis Lab,IST.
F1H
F1P
F1V
F1A
F2H
F2P
F2V
F2A
MEASUREMENT POINT
----------------Fan Inboard Horizontal
Fan Inboard Horz Peakvue
Fan Inboard Vertical
Fan Inboard Axial
Fan Outboard Horizontal
Fan Outboard Horz Peakvue
Fan Outboard Vertical
Fan Outboard Axial
OVERALL LEVEL
------------5.171 mm/Sec
.011 G-s
2.888 mm/Sec
3.875 mm/Sec
4.865 mm/Sec
.011 G-s
3.005 mm/Sec
3.205 mm/Sec
EQUIPMENT SPEED
--------------585.0 RPM (Fan)
1550 RPM (Engine)