2 National Certification Examination 2005 FOR: Energy Auditors Model Test Series - A
2 National Certification Examination 2005 FOR: Energy Auditors Model Test Series - A
FOR
ENERGY AUDITORS
MODEL TEST SERIES A
Paper 4: Energy Performance Assessment for Equipment and Utility Systems
Duration:
Max. Marks: 100
HRS
General instructions:
oPlease check that this question paper contains 16 questions
oThe question paper is divided into three sections
oAll questions in all three sections are compulsory
oAll parts of a question should be answered at one place
oOpen Book Examination
Section I: Short Questions
Marks: 10 x 1 = 10
(i) Answer all Ten questions
(ii) Each question carries One mark
What are the components of surface heat loss in the furnaces and its dependent
factors affecting loss?
How Efficiency and Power Factor varies in motors with VSD Drives.
What are the three reasons for poor fan performance in the field?
What are the measuring instruments required for a compressed air delivery test by
nozzle method ?
Paper 4/ Series A
Page 1 of 4
Marks: 2 x 5 = 10
(i) Answer all Two questions
(ii) Each question carries Five marks
1 A Boiler Efficiency trial was conducted in an Furnace Oil fired process boiler during
Energy Audit Study and the following data were collected.
Boiler Data :
Boiler Rated Capacity
Rated Boiler Efficiency
Actual steam generation pressure
Feed water Temperature
= 5.5% by volume
= Nil
= 240oC
= 0.24
= 0.03 kg/kg of air
Paper 4/ Series A
Page 2 of 4
= 40oC
Paper 4/ Series A
Page 3 of 4
Paper 4/ Series A
Page 4 of 4