Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

PANTEX Lattice Girders

Contents
Introduction................................................................................................................... 3
Fields of Application...................................................................................................... 4
Main Advantages........................................................................................................... 4
System Description....................................................................................................... 4
System Components..................................................................................................... 5
Specifications................................................................................................................ 5
Accessories................................................................................................................... 6
Further References........................................................................................................ 6

Introduction
PANTEX Lattice Girders have been
developed for special demands in the
field of Tunneling. The PANTEX system
has been extensively tested and used
successfully for numerous tunnel projects
throughout the world.
PANTEX Lattice Girders ensure an
immediate support in the open span area.
Contrary to standard solid-web girders,
PANTEX Lattice Girders are entirely
integrated in the shotcrete lining; porous
zones and shotcrete spray shadows are
avoided.
The load-bearing capacity of PANTEX
Lattice Girders has been investigated with
various loading tests and by numerical
analysis. Flexibility regarding geometry
and bearing capacity characterizes this
passive support system for underground
applications.

S2

Passive support system for the


excavated cross section

S3

Fields of Application

H1

Bar S2

Stiffener (spider)

Profile template for the excavation


geometry
Bearing for pre-support elements

Main Advantages
Immediate support in the excavation
area

Bar S3

Utilization as a true-to-form template


for shotcrete application
Easy and quick assembling,
simple handling
Optimum bond and interconnection
with the shotcrete lining
Simple adjustment and shaping to
the excavation geometry
Ideal bearing for spiles and lagging
boards
Spiles may be installed both above
or through the lattice girders

System Description
Load-bearing elements according to
the particular demands in Tunneling

Assembly of the full girder profile by


connecting single girder elements

Spatial 3 or 4 bar girder construction,


connected via stiffening elements

Load transmission even before


shotcrete application

3-bar girder: single bar either at the


excavation or ground side, depending
on the application

Integral part of the shotcrete lining


reinforcement

4-bar girder: application as wallplate


beam or stiff cross girder
Reduction of girder buckling lengths
by stiffeners

Proven bond according to the design


principles of reinforced concrete

System Components
Girder Bars
3-bar girders: 2 + 1 bars

Stiffeners
Smooth or ribbed reinforcing steel

4-bar girders: 2 + 2 bars

Steel grade B 500 B or higher

Smooth or ribbed reinforcing steel


B 500 B (DIN 488-1) or
B 550 B (NORM B 4707)

4 bar stiffeners in one part ensure


optimum bearing capacity

Connections
Angle or alternative flat steel
connection plates
Steel grade S 235 (EN 10025-2)
or higher
Bolts: standard grade 8.8
(EN ISO 898-1)

High strength and great deformability

Slotted bolt or customized


connections available on request
Base plates: standard or elephant
foot version
Special connections available on
request

S2

S3

H1

y
B

Specifications
Gurtstab S2

3-bar girder

Aussteifungselement (Spinne)

No.

Designation 1)

H1

S1

S2

S3

Weight 2)

Wx 3)

Ix

Article No. 4)

[#]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

[PS1-S3-S2]
P50-20-25
P50-20-30
P50-20-36
P50-25-30
P50-25-36
P50-30-36
P70-20-25
P70-20-30
P70-20-36
P70-25-30
P70-25-36
P70-30-36
P95-20-25
P95-20-30
P95-20-36
P95-25-30
P95-25-36
P95-30-36
P115-20-25
P115-20-30
P115-20-36
P115-25-30
P115-25-36
P115-30-36
P130-20-25
P130-20-30
P130-20-36
P130-25-30
P130-25-36
P130-30-36

[mm]

[mm]

10

[mm]
20
20
20
25
25
30
20
20
20
25
25
30
20
20
20
25
25
30
20
20
20
25
25
30
20
20
20
25
25
30

[kg/m]
10.2
11.9
14.3
14.7
17.1
20.5
10.4
12.1
14.5
14.9
17.3
20.7
10.8
12.5
14.9
15.3
17.7
21.1
11.0
12.7
15.1
15.5
17.9
21.3
11.2
12.9
15.3
15.7
18.1
21.5

[mm]
95
100
106
105
111
116
115
120
126
125
131
136
140
145
151
150
156
161
160
165
171
170
176
181
175
180
186
185
191
196

[mm]

50

[mm]
25
30
36
30
36
36
25
30
36
30
36
36
25
30
36
30
36
36
25
30
36
30
36
36
25
30
36
30
36
36

[cm]
11.19
13.35
16.46
16.89
20.00
24.32
11.19
13.35
16.46
16.89
20.00
24.32
11.19
13.35
16.46
16.89
20.00
24.32
11.19
13.35
16.46
16.89
20.00
24.32
11.19
13.35
16.46
16.89
20.00
24.32

[cm]
28
38
42
42
58
64
37
51
54
56
77
83
49
66
69
72
100
107
58
78
82
86
120
126
66
87
91
96
134
141

[cm4]
148
193
246
255
336
424
239
306
383
398
517
644
384
485
598
625
799
986
525
658
804
842
1,070
1,312
644
805
980
1,027
1,299
1,589

[]
14102025XXXX
14102030XXXX
14102036XXXX
14102530XXXX
14102536XXXX
14103036XXXX
14122025XXXX
14122030XXXX
14122036XXXX
14122530XXXX
14122536XXXX
14123036XXXX
14142025XXXX
14142030XXXX
14142036XXXX
14142530XXXX
30 - 50
14142536XXXX
14143036XXXX
14162025XXXX
14162030XXXX
14162036XXXX
14162530XXXX
14162536XXXX
14163036XXXX
14182025XXXX
14182030XXXX
14182036XXXX
14182530XXXX
14182536XXXX
14183036XXXX

70

10

95

10

115

12

130

12

100

140

180

220

220

Gurtstab S3

1) Designation: PH1-S3-S2, e.g. P130-20-30 ; 2) Weight including stiffeners (average values)


3) Quotient moment of inertia and maximum distance from the neutral axis to the outer fiber ; 4) XXXX project-specific designation

4-bar girder
[PH1-S2]
P100-20
P100-25
P100-30
P100-36
P140-20
P140-25
P140-30
P140-36
P190-20
P190-25
P190-30
P190-36
P230-20
P230-25
P230-30
P230-36
P260-20
P260-25
P260-30
P260-36

H1

S1

S2

[mm] [mm] [mm]


20
25
50
10
30
36
20
25
75
10
30
36
20
25
95
10
30
36
20
25
115 10
30
36
20
25
130 10
30
36

Weight 2)

[kg/m]
12.7
14.3
19.4
26.7
13.1
18.5
25.3
35.1
13.9
19,3
26.1
35.9
14.3
19.7
26.5
36.3
14.7
20.1
26.9
36.7

[mm]
140
150
160
172
190
200
210
222
230
240
250
262
270
280
290
302
300
310
320
332

[mm] [cm]
12.57
19.63
100
28.27
40.72
12.57
19.63
140
28.27
40.72
12.57
19.63
180
28.27
40.72
12.57
19.63
220
28.27
40.72
12.57
19.63
220
28.27
40.72

Wx 4) Wy 4) Article No. 3)
[cm3]
65
103
151
222
96
151
219
319
121
190
275
399
146
228
330
479
164
258
372
539

[cm3]
41
56
72
88
65
94
124
161
90
132
178
237
114
170
233
316
114
170
233
316

[]
14200020XXXX
14200025XXXX
14200030XXXX
14200036XXXX
14220020XXXX
14220025XXXX
14220030XXXX
14220036XXXX
14240020XXXX
14240025XXXX
14240030XXXX
14240036XXXX
14260020XXXX
14260025XXXX
14260030XXXX
14260036XXXX
14280020XXXX
14280025XXXX
14280030XXXX
14280036XXXX

S1

H1

Designation 1)

[#]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

No.

B
Gurtstab S2

Ausste

1) Designation: PH1-S2, e.g. P140-30


2) Weight including stiffeners (average values)
3) XXXX project-specific designation
4) Quotient moment of inertia and maximum distance between outer fiber and neutral axis

Accessories
Gurtstab S2

Wallplate beams

Angle connection plates and base plates


Type
Designation
[PH1]

Angle Connections
Angle steel
(B x L x t) 1)
[mm]

Cut length

G 2)

[mm]

[kg]
1.7
1.7
2.1
2.1
2.1
2.5
2.5
2.5
3.0
3.0
3.0
3.2
3.2
3.2

P50

110

P70

138

P95

80 x 120 x 10

Foot Plates

165

P115

200

P130

210

Size
(B x L x t)
[mm]

[kg]

100 x 100 x 10

0.8

140 x 140 x 10

1.6

145 x 180 x 10

2.1

165 x 220 x 10

2.9

180 x 220 x 10

3.2

4-bar girders can be used as wallplate


beams for crown drives
Installation of 90 axial rotated 4-bar
girders in the longitudinal direction
Wallplate beams serve as bearing and
profile template for installation of the
girder arch
Bend-proof frontal connection allows
free crown advancing
At the same time, wallplate beams
30 -50
are considered as statically effective
reinforcement for the foot beam

1) Cut with 60 miter, weight: 15 [kg/m]


2) Weight per single angle - angle connections consists of 4 angle plates

Further References
Ongoing internal factory production
control
External supervision of the
manufacturing process
Certificate of conformity No.
11 7165-1/1, MPA NRW (Germany),
dating 2012-05-24, for the building
product DSI lattice girders type
PANTEX / 3 bars

DSI Austria, Alfred-Wagner-Strae 1, A-4061 Pasching/Linz


Phone: +43-7229-61049-0 E-Mail: office@dywidag-systems.at

Numerical analysis
of the static loadGegenstand der Unterlage / Zeichnung ist unser geistiges
Eigentum.
Zeichnung test
darf ohne unsere vorherige
bearing capacityschriftliche
and Diese
bending
Zustimmung weder vervielfltigt noch Dritten zu
gebracht werden. Sie darf auch nicht in anderer
reports availableKenntnis
on
request
Weise mibruchlich verwendet werden.
(Urheberschutzgesetz v. 09.09.1965)
Allowable tightening
torques and
I:\50_CAD\1410\141020002002.idw
mounting pre-load
for set metrical set
screws: see VDI guideline No. 2230,
sheet 1

Bearb:
Gepr:
Norm

Datum

Name
DDl
WDk

Gruppe
Ersatz fr:

Austria

EMEA
DYWIDAG-Systems International GmbH
Alfred-Wagner-Strasse 1
4061 Pasching/Linz, Austria
Phone +43-7229-610 49 0
Fax
+43-7229-610 49 80
E-mail alwag@dywidag-systems.at
www.alwag.com

Argentina
Australia
belgium

Bosnia and herzegovina


Brazil

Canada

North America
DSI Underground Systems Inc.
9786 S Prosperity Road
West Jordan, UT 84081, USA
Phone +1-801-973 7169
Fax
+1-801-973 7172
E-mail dsiunderground@dsiunderground.com
www.dsiunderground.com

Chile

Colombia

C o s t a R i ca

Croatia

Czech republic

Denmark

South America
DSI Chile Industrial Ltda.
Las Encinas #1387, Valle Grande
Lampa, Santiago de Chile, Chile
Phone +56-2-596 96 20
Fax
+56-2-596 96 69
E-mail informaciones@dywidag-systems.cl
www.dsi-chile.com

Egypt

estonia
Finland

France

Germany
Greece

APAC/ASEAN
DYWIDAG-Systems International Pty. Ltd.
25 Pacific Highway
Bennetts Green, NSW 2290, Australia
Phone +61-2-49 48 90 99
Fax
+61-2-49 48 99 56
E-mail dsi@dywidag.com.au
www.dsiminingproducts.com/au

GU A TEM A L A
HONDUR A S

Hong Kong
Indonesia

Italy

Japan

Korea

Lebanon

Luxembourg

Ma l a y s i a
Mexico

Netherlands

Norway
Oman

Pa n a m a

Pa r a g u a y

Peru

POL A ND

Portugal

Qatar

Sa u d i A r a b i a
singapore

S o u t h A f r i ca

Spain

Sweden

Switzerland

Ta i w a n

Thailand

Turkey

ALWAG (AM 952/79), AT (AM 6138/2003),


AT-SYSTEM (AM 6139/2003),
DYWI (4197869), LSC (AM 4326/2008),
OMEGA-BOLT (3258282),
POWER SET (AM 6163/2002), and
TUBESPILE (AM 4328/2008) are registered
trademarks of DYWIDAG-Systems International GmbH.
Combi Coat and CT-Bolt are trademarks
of Vik rsta AS.
DYWIDAG-Systems International GmbH
is a partner of Vik rsta AS.

United kingdom
Uruguay

US A
Venezuela

04195-1/04.13-web-he

Please note:
This brochure serves basic information
purposes only. Technical data and information
provided herein shall be considered
non-binding and may be subject to change
without notice. We do not assume any liability
for losses or damages attributed to the use
of this technical data and any improper
use of our products. Should you require
further information on particular products,
please do not hesitate to contact us.

United Arab Emirates

You might also like