Abstract : The Visualization Society of Japan started a project for PIV standardization and
popularization in 1996. The objectives of this project are to popularize the complicated PIV system,
and to be a standard tool for the measurement of flow field. The PIV-STD developed the PIV
standard images to provide the evaluation tool for the PIV techniques. The new images were based
on the transient three-dimensional motion. The developed PIV standard images are distributed
using the Internet (http://www.vsj.or.jp/piv), and can be accessed around the world through the
Internet. They can be applied for the performance investigation of any PIV techniques. Comparing
with the traditional measurement technique, e.g., Laser Doppler Velocimeter and Hot Wire
Anemometer, the whole field measurement is a great advantage to investigate the flow field. (10 to
15 lines)
Keywords : Visualization, PIV, Standard, Internet, Popularization. (about 5 items)
1. Introduction
The Particle Imaging Velocimetry (PIV) is a quantitative velocity measurement technique, with visualizing the
flow field by small tracer particles and with analyzing the visualized digital images. The PIV can measure the
whole two-dimensional or three-dimensional flow field simultaneously without disturbing the flow field.
Comparing with the traditional measurement technique, e.g., Laser Doppler Velocimeter and Hot Wire
Anemometer, the whole field measurement is a great advantage to investigate the flow field.
Lots of PIV techniques had been developed and applied to various flow fields. The techniques include
Cross-correlation technique (e.g., Adrian, 1991), Four-step particle tracking technique (e.g., Kobayashi et al.,
1989), and so on. The developers analyzed the effectiveness of their PIV techniques using their own evaluation.
There are no standard evaluation tools for investigating these PIV techniques, resulting in the no standard PIV
techniques. Therefore, the users should determine the selection of the appropriate PIV technique without any
useful information. When the users could get the velocity distribution using some PIV technique, there also were
no standard evaluation tools for the measured velocity data. In order to get the accuracy information of there
measured data, they have to evaluate the data by their-selves. Also, the PIV system needs lots of know-how,
because the PIV system contains many steps, i.e., test section fabrication, visualization, image capture, image
analysis, particle tracking, and evaluation of accuracy.
The current status of the PIV technique is far from the popularization or generalization technique. To
popularize the PIV technique for practical use, the PIV standards and the PIV guide tools should be settled. With
using the PIV standards, any user can easily apply the PIV technique onto their target flow field with the accuracy
information.
2. Standard Images
2.1 Computer Graphics
With considering the camera location and orientation vector, the global coordinate has been transformed to the
camera coordinate system with a simple linear transformation. Then, the particle projection (X, Y) on the camera is
calculated with considering the refraction at the vessel wall. To determine the refracted light path, the light path
length between camera focus and particle is set to be minimum. In this study, one or three cameras are used to
capture the flow field with the particles.
The image size is fixed to be 256x256 pixels. One pixel has 256 intensity levels (8bit). The particle image is
generated with writing the particle onto the image. The intensity at the location (X,Y) in the image caused by the
scatter from the particle (xp, yp, zp) whose projection is (Xp, Yp), is
Fig. 1 Experimental setup for the verification test (This figure is only sample.)
expressed as follows,
( X X p )2 + (Y Y p ) 2
I ( X ,Y ) = I 0 exp
2S
(1)
velocity distributions are also distributed. All of the recorded particles had its own ID number. Since the particle
positions are written on the file with the ID, it is very easy to track the actual particle movement.
Fig. 3 Pressure field on the surface of a delta wing (This figure is only sample.)
technique, the particle centroids are calculated from the image, with using the Laplace filtering and binarization.
The maximum number of the particle in one cluster is 18, and search area is 10 pixels. Since the number of
particles in the image is relatively large, the cross-correlation technique gives a better result. Also, the images
contain no noise, therefore, there are almost no erroneous vectors. The spring model can track the individual
particles with relatively high accuracy.
4. Conclusion
The standard images which aim to establish an evaluation code of PIV were proposed. The standard images have
been developed based on the calculated velocity field by means of three-dimensional LES.
The transient and three-dimensional motions are taking into account in the standard images. To generate the
images, the wall refraction at the vessel surface is considered. The effectiveness of the present standard images is
References
Adrian, R. J., Particle-imaging techniques for experimental fluid mechanics, Ann. Rev. Fluid Mech., 23 (1991), 261-268.
Haridi, S., Numerical data visualization method, to appear in Journal of Visualization, 2004.
Kobayashi, T., Saga, T., Segawa, S. and Knada, H., Development of a Real-Time Velocity Measurement System for
Two-Dimensional Flow Fields Using a Digital Image Processing Technique, Trans. of JSME, 55-509, B (1989), 107-112.
Massey, B. S., Mechanics of Fluids (Sixth edition), (1991), 123, Chapman & Hall, London.
Okamoto, K., Hassan, Y. A. and Schmidl, W. D., New Tracking Algorithm for Particle Image Velocimetry, Experiment in
Fluids, 19-5 (1995), 342-347.
Warren, Y. and Smith, I., Visualization of Medical Images, Journal of Visualization, 7-1(1996), 37-58.
Yamanouchi, K. and Furukawa, K., Visualization using Tracer Method, Proceedings of the Fifth International Symposium on
Visualization (Tokyo), (1996-5), 582-591, IOS Press and Ohmsha.
Author Profile
Koji Okamoto: He received his M.Sc.(Eng) in Nuclear Engineering in 1985 from University of Tokyo. He also received his
Ph.D. in Nuclear Engineering in 1992 from University of Tokyo. He worked in Department of Nuclear Engineering, Texas A &
M University as a visiting associate professor in 1994. He works in Nuclear Engineering Research Laboratory, University of
Tokyo as an associate professor since 1993. His research interests are Quantitative Visualization, PIV, Holographic PIV Flow
Induced Vibration and Thermal-hydraulics in Nuclear Power Plant.
(within 100 words with a color photograph (3x2.5cm) of the author)
Makoto Oki: He received his M.Sc.(Eng.) degree in Mechanical Engineering in 1976 from Tokai University and his Ph.D. in
Mechanical Engineering in 2000 from the same university. After obtaining M. Sc. he worked as a system engineer at Japan
Advanced Numerical Analysis, Inc.. He then became an assistant professor of Tokai University, and currently is an associate
professor. His current research interests are computational fluid dynamics, computer graphics and internet application.
(within 100 words with a color photograph (3x2.5cm) of the author)