Experiment No: 7 Name of The Experiment: Steady State AC Analysis and Frequency Response

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 8

Experiment No: 7

Name of the Experiment: Steady state AC analysis and frequency response


1. High Pass Filter:
Circuit Diagram:

Input File:
High pass frequency
V2 1 0 Ac 1v
C1 1 2 100u
R1 2 0 1.59
.Ac dec 20 100 100000
.probe
.end
Output File:
**** 10/04/15 23:22:52 ******* Evaluation PSpice (Nov 1999) High pass frequency ****
CIRCUIT DESCRIPTION
V2 1 0 Ac 1v
C1 1 2 100u
R1 2 0 1.59
.Ac dec 20 100 100000
.probe
.end
**** 10/04/15 23:22:52 *********** Evaluation PSpice (Nov 1999) **************

High pass frequency


NODE VOLTAGE
(

1)

0.0000 (

2)

NODE VOLTAGE

NODE VOLTAGE

NODE VOLTAGE

0.0000

VOLTAGE SOURCE CURRENTS


NAME
V2

CURRENT
0.000E+00

TOTAL POWER DISSIPATION 0.00E+00 WATTS


JOB CONCLUDED
TOTAL JOB TIME

.05

The half power frequency:


At -3db point:
0

(1.0000K,-3.0145)

-10

-20

-30
100Hz
300Hz
DB(V2(R1)/V1(V2))

1.0KHz

3.0KHz
Frequency

The half power frequency:

10KHz

30KHz

100KHz

1.0

(1.0000K,706.762m)

0.5

0
100Hz
300Hz
V2(R1) / V1(V2)

1.0KHz

3.0KHz
Frequency

2. Low pass filter:


Circuit diagram:

Input file:
Low pass filter

10KHz

30KHz

100KHz

V1 1 0 ac 1
R1 1 2 .25
C1 2 0 50u
.ac dec 20 100 100000
.probe
.end
Output File:
10/04/15 23:27:55 *********** Evaluation PSpice (Nov 1999) **************
Low pass filter
CIRCUIT DESCRIPTION
V1 1 0 ac 1
R1 1 2 .25
C1 2 0 50u
.ac dec 20 100 100000
.probe
.end
**** 10/04/15 23:27:55 *********** Evaluation PSpice (Nov 1999) ************** Low
pass filter
****

SMALL SIGNAL BIAS SOLUTION

NODE VOLTAGE NODE VOLTAGE


0.0000 ( 2) 0.0000

TEMPERATURE = 27.000 DEG C


NODE VOLTAGE

VOLTAGE SOURCE CURRENTS


NAME
V1

CURRENT

0.000E+00

TOTAL POWER DISSIPATION 0.00E+00 WATTS


JOB CONCLUDED TOTAL JOB TIME

Half power frequency:

0.00

NODE VOLTAGE(

1)

1.0

(12.686K,708.322m)

0.5

0
100Hz
300Hz
V1(C1) / V1(V1)

1.0KHz

3.0KHz

10KHz

30KHz

100KHz

Frequency

Half power frequency at -3db point:


0
(12.686K,-2.9964)

-5

-10

-15

-20
100Hz
300Hz
DB(V1(C1)/V1(V1))

1.0KHz

3.0KHz
Frequency

3. Band pass filter :

10KHz

30KHz

100KHz

Highest value:
400mV
(1.0000K,333.333m)

300mV

200mV

100mV

0V
100Hz
V(R2:2)

300Hz

1.0KHz

3.0KHz
Frequency

Normalization to determine band width:

10KHz

30KHz

100KHz

1.2

0.8

(304.322,708.728m)

(3.2860K,709.553m)

0.4

0
100Hz
300Hz
V(R2:2) / V1(V1) /333.33m

1.0KHz

3.0KHz
Frequency

So, band width


=2982 hz

= (3286-304)hz

4. Band stop:
Circuit diagram:

Band stop against L in RLC circuit:

10KHz

30KHz

100KHz

3.0

2.0

1.0

0
10Hz
100Hz
V(L2:1) / V1(V1)

1.0KHz

10KHz
Frequency

100KHz

1.0MHz

10MHz

You might also like