EXAMPLE 1.

Estimate the fugacity of gaseous propane at 2.4 MPa. and 344 K using the following p-v-T
data for propane at 160F.
Pressure

Specific
Volume

MN/m2

m3/kg

---

0.1724
0.3447

0.3691
0.181

Ideal
Specific
Volume
m3/kg
--0.3776
0.1888

x 103
m3/kg

7.88

1.0342

0.05512

0.06293

7.81

1.2066

0.04598

0.05394

7.96

1.379

0.03903

0.0472

8.17
9.14

m 3 MN
x 2 x106 = 19248.5 J/kg
kg m
ln(f/p) = -1/RT dp = -19248.5/(8314 x 344.4) x 44 = -0.2956
[44 is RMM of propane needed since R is in kJ/mol/K]
f/p = 0.7441
f = 0.7441 x 2.4 = 1.7856 MPa