Marking Convention Final 230614

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 30

Item

BTS Cabinet
Indoor jumper cable marking at BTS end
Indoor Feeder marking
feeder marking after roxtec
feeder marking outdoor jumper end
outdoor jumper marking at feeder end
outdoor jumper marking at antenna end
Power cable marking at BTS end
Power cable marking at BTS end ( Neutral)
Power cable marking at source end
Power cable marking at source end ( Neutral)
Alarm Box
Alarm cable marking BTS end
Alarm cable marking alarm box end
External alarm marking @ alarm box end
External alarm marking @ Source End
PCM/E1 marking bts end
PCM/E1 marking at DDF end
(As per LDMA Definition - See below table**)
Sync Cable marking (@ Both ends)
grounding cable marking BTS end
grounding cable marking @ BUS bar
Alarm box grounding marking at Box end
Alarm box grounding marking @ BUS bar
Optical (CPRI) cable marking (BTS/Node B to RRU)
@ BTS/Node B end
Optical (CPRI) cable marking (BTS/Node B to RRU)
@ after ROXTEC
Optical (CPRI) cable marking (BTS/Node B to RRU)
@ RRU end
Power cable marking (BTS/Node B to RRU) @
BTS/Node B end
Power cable marking (BTS/Node B to RRU) @
BTS/Node B end
Power cable marking (BTS/Node B to RRU) @
BTS/Node B end
** LDMA convention - E1 Name
900
D
D2
M
I
F

E
W
W1

Item
TX rack marking
TX rack grounding cable marking @ rack end
TX rack grounding cable marking @ BUS bar end
**NE/IDU marking (For Nodal Solution)
NE/IDU marking (For Single/ Stand alone IDU)
IF cable/ Link name marking at IDU end
IF cable marking after roxtec end
IF cable marking @ ODU end
IF card/MMU card marking
Antenna marking
IDU grounding marking IDU end
IDU grounding marking BAR end
PCM cable marking at IDU end
PCM cable marking at DDF end
IDU power cable marking at IDU end
IDU power cable marking at DCDB/rectifier end
Crone block marking
E1 cross connection marking
If cable grounding marking
ODU grounding marking
LAN/NMS cable Marking

Convention

Example - 1

BTS_Site Code_900/1800/Node B
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Voltage_From source Name
Neutral_From source Name
Voltage_BTS_900/1800/Node B
Neutral_BTS_900/1800/Node B
Alarm Box
External Alarm cable
External Alarm cable
Alarm Name
Alarm Name
E1_900/1800/2100

BTS_DHXXX01_900
Sector_1_TX_1800
Sector_1_RX_1800
Sector_1_RX_1800
Sector_1_RX_1800
Sector_1_RX_1800
Sector_1_RX_1800
-48 V_Rect
0 V_Rect
-48 V_BTS_900
0 V_BTS_900
Alarm Box
EXT_Alarm
EXT_Alarm_BTS

E1 Name_Site Code(FE Site Code_Port No.)


Sync Cable
GND
BTS_900/1800/Node B
GND
Alarm Box_900/1800/Node B

Mains Fail
Mains Fail
E1_900
900_NGSDR02(NGSDR03_1)
Sync Cable
GND
BTS_1800
GND
Alarm Box_1800

Sector_#_Optical_Band (Optical_Band: For Single


RRU)

Optical_Node B

Sector_#_Optical_Band (Optical_Band: For Single


RRU)

Optical_Node B

Sector_#_Optical_Band (Optical_Band: For Single


RRU)

Optical_Node B

Sector_#_PWR_Band (PWR_Band: For Single


RRU)

PWR_Node B

Sector_#_PWR_Band (PWR_Band: For Single


RRU)

PWR_Node B

Sector_#_PWR_Band (PWR_Band: For Single


RRU)

PWR_Node B

900 BTS
1800_1_BTS
1800_2 (3rd cab_BTS)
Micro BTS
IBS
900_2nd E1

EDGE
Node B
2nd Node B

Convention

Example

TX Rack_#
TX Rack_1
GND
GND
TX Rack_#
TX Rack_2
IDU_Link Model_#
IDU_TN_1
IDU_Link Model_Far End Site Code
IDU_Minilink_BSSDR03
FE Site Code_Main/STBY
BSSDR03_Main
IF_FE Site Code_Main/STBY
IF_BSSDR03_Main
IF_FE Site Code_Main/STBY
IF_BSSDR03_Main
FE Site Code_Main/STBY
BSSDR03_Main
FE Site Code
DHGUL05
GND
GND
GND_IDU Name (As per Previos Convention**)
GND_IDU_TN_2
FE Site Code_E1_#-#
DHGUL05_E1_1-4
FE Site Code_E1_#-#
DHGUL05_E1_1_4
Voltage_From source Name
-48 V_Rect
Voltage_Site Code_IDU Name**
-48 V_IDU_TN_2
FE Site Code_E1_#-#/FE Site Code_TX/RX_#-#
DHGUL05_E1_1-4, DHGUL05_E1_5-8
ame_Site Code(FE Site Code(BSC)_Port No.CC FE Site Code (BTS)_Port
D2_NGSDR02(NGSDR03_6
No.)
CC NSRPG07_2)

Example - 2

Example - 3

Node B_DHXXX01_2100
Sector_1_RX_1800
Sector_1_TX_1800
Sector_1_TX_1800
Sector_1_TX_1800
Sector_1_TX_1800
Sector_1_TX_1800
-48 V_DCDB_1
0 V_DCDB_1
-48 V_Node B
0 V_Node B

Sector_1_TX/RX_1800
Sector_1_TX/RX_1801
Sector_1_TX/RX_1802
Sector_1_TX/RX_1803
Sector_1_TX/RX_1804
Sector_1_TX/RX_1805
-48V_DCDB_2
0V_DCDB_2
-48 V_BTS_1800
0 V_BTS_1800

EXT_Alarm_Node B
Door Open
Door Open
E1_1800
D_NGSDR02(NGSDR03_3)

DC Low
DC Low
E1_1800_EDGE
M_NGSDR02(NGSDR03_4)

BTS_Node B
Alarm Box_Node B
Sector_2_Optical_900

Sector_1_Optical_1800

Sector_2_Optical_900

Sector_2_Optical_1800

Sector_2_Optical_900

Sector_3_Optical_Node B

Sector_2_PWR_900

Sector_1_PWR_1800

Sector_2_PWR_900

Sector_2_PWR_1800

Sector_2_PWR_900

Sector_3_PWR_Node B

RTN_2
BSSDR03_STBY
IF_BSSDR03_STBY
IF_BSSDR03_STBY
BSSDR03_STBY

GND_IDU_Minilink_BSSDR03
DHGUL05_E1_5-8
DHGUL05_E1_5-8
-48 V_DCDB_1
-48 V_IDU_Minilink_BSSDR03
DHGUL05_E1_TX_1-4, DHGUL05_E1_RX_1-4,
D2_NGSDR02(NGSDR03_6 CC NSRPG02_2)

Rect Fail
Rect Fail

Water
Water

Temp
Temp

Smoke
Smoke

Gen On
Gen On

Low Fuel
Low Fuel

Gen Service
Gen Service

Item
TX rack marking
TX rack grounding cable marking @ rack end
TX rack grounding cable marking @ BUS bar end
**NE/IDU marking (For Nodal Solution)
NE/IDU marking (For Single/ Stand alone IDU)
IF cable/ Link name marking at IDU end
IF cable marking after roxtec end
IF cable marking @ ODU end
IF card/MMU card marking
Antenna marking
IDU grounding marking IDU end
IDU grounding marking BAR end
PCM cable marking at IDU end
PCM cable marking at DDF end
IDU power cable marking at IDU end
IDU power cable marking at DCDB/rectifier end
Crone block marking
E1 cross connection marking
If cable grounding marking
ODU grounding marking
LAN/NMS cable Marking

Link Model
TN
RTN
ALU
Minilink
Stratex

Convention
TX Rack_#
GND
TX Rack_#
IDU_Link Model_#
IDU_Link Model_Far End Site Code
FE Site Code_Main/STBY
IF_FE Site Code_Main/STBY
IF_FE Site Code_Main/STBY
FE Site Code_Main/STBY
FE Site Code
GND
GND_IDU Name (As per Previos Convention**)
FE Site Code_E1_#-#
FE Site Code_E1_#-#
Voltage_From source Name
Voltage_Site Code_IDU Name**
FE Site Code_E1_#-#/FE Site Code_TX/RX_#-#
E1 Name_Site Code(FE Site Code(BSC)_Port No.CC FE Site Code (BTS)_Port No.)

Solution
Nodal
Nodal
Single IDU
Single IDU
Single IDU

Example
TX Rack_1
GND
TX Rack_2
IDU_TN_1
IDU_Minilink_BSSDR03
BSSDR03_Main
IF_BSSDR03_Main
IF_BSSDR03_Main
BSSDR03_Main
DHGUL05
GND
GND_IDU_TN_2
DHGUL05_E1_1-4
DHGUL05_E1_1_4
-48 V_Rect
-48 V_IDU_TN_2
DHGUL05_E1_1-4, DHGUL05_E1_5-8
D2_NGSDR02(NGSDR03_6 CC NSRPG07_2)

RTN_2
BSSDR03_STBY
IF_BSSDR03_STBY
IF_BSSDR03_STBY
BSSDR03_STBY

GND_IDU_Minilink_BSSDR03
DHGUL05_E1_5-8
DHGUL05_E1_5-8
-48 V_DCDB_1
-48 V_IDU_Minilink_BSSDR03
DHGUL05_E1_TX_1-4, DHGUL05_E1_RX_1-4,
D2_NGSDR02(NGSDR03_6 CC NSRPG02_2)

Sl No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Item
MUX marking
Mux Sub rack/Cabinet grounding marking Mux end
MUX grounding marking at Grounding Bar end
MUX PCM/E1/Tributary cable marking at DDF end
MUX power cable marking at Sub-rack end
DDF marking
DDF crone block marking
DDF E1 cross conection (loop) marking
Alarms DDF crone block marking
LAN/NMS cable Marking
TX Sub rack/Cabinet marking
Power TRU(Top Rack Unit) marking
MUX PCM/E1/Tributary cable marking at MUX end
MUX power cable marking at DCDB/PDF/rectifier both end
Link marking

Convention

Site code_MUX Model Name_No


GND_MUX Model Name_No_BAR_#
GND_MUX Model Name_No_BAR_#
Site code_MUX Model Name_No_Slot_Port
Voltage_MUX Model Name_No_PDF/DCDB/Rectifier _Model_No
Site code_MUX Model Name_No
Site code_MUX Model Name_No_Slot_Port
Site code_MUX Model Name_No_Slot_Port - Site code_MUX Model Name_No_Slot_Port
Site code_MUX Model Name_No_Slot_Port _Alarm Name
LAN/NMS cable _Site code_MUX Model Name_No-Site Code_Router/MUX Model Name_No_Por

Far end MUX name_ slot and port Link Type

Example
DHGUL58_SPO1460_1
GND_SPO1460_1_BAR_2
GND_SPO1460_1_BAR_2
DHGUL58_SPO1460_1_S15_P01
-48V DC_SPO1460_1_PDF_1
DHGUL58_SPO1460_1
DHGUL58_SPO1460_1_S15_P01
DHGUL58_SPO1460_2_S15_P20- DHGUL58_TH20_1_S11_P10
DHGUL58_SPO1460_1_S19_P01_MAINS FAILURE
LAN/NMS Cable_DHGUL58_SPO1460_2-DHGUL58_ROUTER SWITCH_P10

DHGUL58_SPO_1_S01P01-ROBI_ FO _CORE_12, 13
DHGUL58_SPO_1_S05P01-MW-SDH_TN20P_S19
NGRPG01_OSN_1_S11P01 -BPL_ME100_S5P01
NGRPG01_OSN_1_S08P01 -WDM_ ROBI_ FO _CORE_12, 13

Item
Site Identification on Door
Site log book
Rectifier cabinet marking
AC cable power marking at rectifer end
Battery cable marking at rectifier end
Rectifier cabinet grounding marking
grounding cable marking rectifier end
alarm cable marking rectifer end
Indivdual alarm marking at rectifier end
DCDB power cable marking at rectifier end
IVS cable marking Rectifier end
BTS cable marking rectifier end
MW cable marking rectifier end
AC circuit breaker marking in rectifier
Priority load & non Priority load marking
Temperature sensor cable marking at rectifier end
smoke alarm sensor marking
Water alarm sensor marking
Temp alarm sensor marking
Door alarm sensor marking
Battery Bank Marking
DC cable marking at battery bank end
Grounding cable marking battery bank end
IVS controller Marking
IVS inlet marking
IVS outlet Marking
AC Marking
AC timer marking
BTS grounding cable marking at MGB end
Alarm box grounding cable marking at MGB end
Rectifier grounding cable marking at MGB end
IVS controller grounding cable Marking at MGB end
Battery rack grounding cable marking at MGB end
indoor ladder grounding cable marking at MGB end
MW grounding cable marking MGB end
MW equipment/other grounding cable marking at MGB end
MDB grounding marking at MGB end
Outdoor grounding Bar marking
IF cable grounding marking
Feeder cable grouning marking
ODU Grounding making
TMF grounding marking
Combiner grounding marking
Remote Radio grounding marking

Lighting arestator
MDB marking
MDB main circuit breaker marking
MDB rectifier circuit breaker marking
Air Conditioner (AC) CKT breaker marking
MDB light/socket circuit breaker marking
MDB AC circuit breaker marking
MDB aviation light circuit breaker marking
MDB gounding cable marking
MDB search protector markig
MDB mains AC power cable marking
Aviation light controller marking
LLBD/BLVD marking in rectifier
ACDB/DCDB marking

Convention

Example

Site Code
Site Code
Site Code_Rectifier_Model
Votage AC
Voltage_Battery Bank_#
GND_Rectifier_Model
GND_BAR_#
Alarm Cable
Mains Fail, DC Low, Rectifier Fault
Voltage_DCDB_#
Voltage_IVS
Voltage_BTS_900/1800/2100
Voltage_Site Code_Link Model_#
Mains_MDB
Priority /Non Priority load
Temperature sensor
smoke alarm sensor
Water alarm sensor
Temp alarm sensor
Door alarm sensor
Battery Bank_#
Voltage_Rectifier_Model
GND_Battery Bank_#_BAR_#
IVS controller
IVS inlet
IVS outlet
AC_#
AC Timer
GND_BTS_900/1800/2100_BAR_#
GND_Alarm Box_BAR_#
GND_Rectifier_BAR_#
GND_IVS Controller_BAR_#
GND_Battery Bank_#_BAR_#
GND_Indoor Ladder_#_BAR_#
GND_IDU Name ( NE)_BAR_#
GND_IDU Name ( NE)_BAR_#
GND_MDB_BAR_#

DHBDD03
DHBDD03
DHBDD03_Rectifier_Emerson
220/440 V AC
-48V DC_Battery Bank_1
GND_Rectifier_Eltek
GND_BAR_2
Alarm Cable
Mains Fail, DC Low, Rectifier Fault
-48V DC_DCDB_1
-48V DC_IVS
-48V DC_BTS_1800
-48 V_DHBDD03_TN_2
Mains_MDB
Priority /Non Priority load
Temperature sensor
smoke alarm sensor
Water alarm sensor
Temp alarm sensor
Door alarm sensor
Battery Bank_1
-48V DC_Rectifier_Eltek
GND_Battery Bank_2_BAR_1
IVS controller
IVS inlet
IVS outlet
AC_2
AC Timer
GND_BTS_2100_BAR_1
GND_Alarm Box_BAR_1
GND_Rectifier_BAR_2
GND_IVS Controller_BAR_2
GND_Battery Bank_2_BAR_1
GND_Indoor Ladder_2_BAR_1
GND_NSSDR01_TN_2_BAR_3
GND_NSSDR01_TN_2_BAR_3
GND_MDB_BAR_1

GND_ODU_FE Site Code_Main/STBY


GND_TMF_Sector_#
GND_Combiner_Site Code
GND_RRU_Sector_#

GND_ODU_BSSDR09_Main
GND_TMF_Sector_3
GND_Combiner_NGSDR20
GND_RRU_Sector_3

MDB
Voltage_Mains
Rectifier_Model
AC_#/AC Timer
Light/Socket
Mains
Aviation light
GND_BAR_#
search protector
Votage AC
Aviation light controller
LLBD/BLVD marking in rectifier
ACDB/DCDB_#

MDB
-440V AC_Mains
Rectifier_Eltek
AC_1
Light/Socket
Mains
Aviation light
GND_BAR_2
search protector
220/440 V AC
Aviation light controller
DCDB_1

DCDB_2

1
2

Site Name
Site Code

Before entry, Send SMS

O,site code
or
1819210350

Call SOC 24/7

3667

Item

Convention

BTS Cabinet
Indoor jumper cable marking at BTS end
Indoor Feeder marking
feeder marking after roxtec
feeder marking outdoor jumper end
outdoor jumper marking at feeder end
outdoor jumper marking at antenna end
Power cable marking at BTS end
Power cable marking at BTS end ( Neutral)
Power cable marking at source end
Power cable marking at source end ( Neutral)
Alarm Box
Alarm cable marking BTS end
Alarm cable marking alarm box end
External alarm marking @ alarm box end
External alarm marking @ Source End
PCM/E1 marking bts end

BTS_Site Code_900/1800/Node B
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Sector_#_TX/RX_Band
Voltage_From source Name
Neutral_From source Name
Voltage_BTS_900/1800/Node B
Neutral_BTS_900/1800/Node B
Alarm Box
External Alarm cable
External Alarm cable
Alarm Name
Alarm Name
E1_900/1800/2100

PCM/E1 marking at DDF end


(As per LDMA Definition - See below table**)
Sync Cable marking (@ Both ends)
grounding cable marking BTS end
grounding cable marking @ BUS bar
Alarm box grounding marking at Box end
Alarm box grounding marking @ BUS bar

E1 Name_Site Code(FE Site Code_Port No.)


Sync Cable
GND
BTS_900/1800/Node B
GND
Alarm Box_900/1800/Node B

Optical (CPRI) cable marking


Sector_#_Optical_Band
(BTS/Node B to RRU) @ BTS/Node (Optical_Band: For Single
RRU)
B end
Optical (CPRI) cable marking (BTS/Node B to RRU) Sector_#_Optical_Band (Optical_Band: For Single
@ after ROXTEC
RRU)
Optical (CPRI) cable marking (BTS/Node B to RRU) Sector_#_Optical_Band (Optical_Band: For Single
@ RRU end
RRU)
Power cable marking (BTS/Node B to RRU) @
BTS/Node B end

Sector_#_PWR_Band (PWR_Band: For Single


RRU)

Power cable marking (BTS/Node B to RRU) @


BTS/Node B end

Sector_#_PWR_Band (PWR_Band: For Single


RRU)

Power cable marking (BTS/Node B to RRU) @


BTS/Node B end

Sector_#_PWR_Band (PWR_Band: For Single


RRU)

Item

Convention

TX rack marking
TX Rack_#
TX rack grounding cable marking @ rack end
GND
TX rack grounding cable marking @ BUS bar end
TX Rack_#
**NE/IDU marking (For Nodal Solution)
IDU_Link Model_#
NE/IDU marking (For Single/ Stand alone IDU)
IDU_Link Model_Far End Site Code
IF cable/ Link name marking at IDU end
FE Site Code_Main/STBY
IF cable marking after roxtec end
IF_FE Site Code_Main/STBY
IF cable marking @ ODU end
IF_FE Site Code_Main/STBY
IF card/MMU card marking
FE Site Code_Main/STBY
Antenna marking
FE Site Code
IDU grounding marking IDU end
GND
IDU grounding marking BAR end
GND_IDU Name (As per Previos Convention**)
PCM cable marking at IDU end
FE Site Code_E1_#-#
PCM cable marking at DDF end
FE Site Code_E1_#-#
IDU power cable marking at IDU end
Voltage_From source Name
IDU power cable marking at DCDB/rectifier end
Voltage_Site Code_IDU Name**
Crone block marking
FE Site Code_E1_#-#/FE Site Code_TX/RX_#-#
E1 cross connection marking
E1 Name_Site Code(FE Site Code(BSC)_Port No.CC FE Site Code (BTS)_Port No.)
If cable grounding marking

ODU grounding marking


LAN/NMS cable Marking

Item

Convention

Site Identification on Door


Site log book
Rectifier cabinet marking
AC cable power marking at rectifer end
Battery cable marking at rectifier end
Rectifier cabinet grounding marking
grounding cable marking rectifier end
alarm cable marking rectifer end
Indivdual alarm marking at rectifier end
DCDB power cable marking at rectifier end
IVS cable marking Rectifier end
BTS cable marking rectifier end
MW cable marking rectifier end
AC circuit breaker marking in rectifier
Priority load & non Priority load marking
Temperature sensor cable marking at rectifier end
smoke alarm sensor marking
Water alarm sensor marking
Temp alarm sensor marking
Door alarm sensor marking
Battery Bank Marking
DC cable marking at battery bank end
Grounding cable marking battery bank end
IVS controller Marking
IVS inlet marking
IVS outlet Marking
AC Marking
AC timer marking
BTS grounding cable marking at MGB end
Alarm box grounding cable marking at MGB end
Rectifier grounding cable marking at MGB end
IVS controller grounding cable Marking at MGB end
Battery rack grounding cable marking at MGB end
indoor ladder grounding cable marking at MGB end
MW grounding cable marking MGB end
MW equipment/other grounding cable marking at MGB end

Site Code
Site Code
Site Code_Rectifier_Model
Votage AC
Voltage_Battery Bank_#
GND_Rectifier_Model
GND_BAR_#
Alarm Cable
Mains Fail, DC Low, Rectifier Fault
Voltage_DCDB_#
Voltage_IVS
Voltage_BTS_900/1800/2100
Voltage_Site Code_Link Model_#
Mains_MDB
Priority /Non Priority load
Temperature sensor
smoke alarm sensor
Water alarm sensor
Temp alarm sensor
Door alarm sensor
Battery Bank_#
Voltage_Rectifier_Model
GND_Battery Bank_#_BAR_#
IVS controller
IVS inlet
IVS outlet
AC_#
AC Timer
GND_BTS_900/1800/2100_BAR_#
GND_Alarm Box_BAR_#
GND_Rectifier_BAR_#
GND_IVS Controller_BAR_#
GND_Battery Bank_#_BAR_#
GND_Indoor Ladder_#_BAR_#
GND_IDU Name ( NE)_BAR_#
GND_IDU Name ( NE)_BAR_#

MDB grounding marking at MGB end


Outdoor grounding Bar marking
IF cable grounding marking
Feeder cable grouning marking
ODU Grounding making
TMF grounding marking
Combiner grounding marking
Remote Radio grounding marking
Lighting arestator
MDB marking
MDB main circuit breaker marking
MDB rectifier circuit breaker marking
Air Conditioner (AC) CKT breaker marking
MDB light/socket circuit breaker marking
MDB AC circuit breaker marking
MDB aviation light circuit breaker marking
MDB gounding cable marking
MDB search protector markig
MDB mains AC power cable marking
Aviation light controller marking
LLBD/BLVD marking in rectifier
ACDB/DCDB marking

GND_MDB_BAR_#

GND_ODU_FE Site Code_Main/STBY


GND_TMF_Sector_#
GND_Combiner_Site Code
GND_RRU_Sector_#
MDB
Voltage_Mains
Rectifier_Model
AC_#/AC Timer
Light/Socket
Mains
Aviation light
GND_BAR_#
search protector
Votage AC
Aviation light controller
LLBD/BLVD marking in rectifier
ACDB/DCDB_#

Example - 1

Example - 2

BTS_DHXXX01_900
Sector_1_TX_1800
Sector_1_RX_1800
Sector_1_RX_1800
Sector_1_RX_1800
Sector_1_RX_1800
Sector_1_RX_1800
-48 V_Rect
0 V_Rect
-48 V_BTS_900
0 V_BTS_900
Alarm Box
EXT_Alarm
EXT_Alarm_BTS

Node B_DHXXX01_2100
Sector_1_RX_1800
Sector_1_TX_1800
Sector_1_TX_1800
Sector_1_TX_1800
Sector_1_TX_1800
Sector_1_TX_1800
-48 V_DCDB_1
0 V_DCDB_1
-48 V_Node B
0 V_Node B

Mains Fail
Mains Fail

EXT_Alarm_Node B
Door Open
Door Open

E1_900
900_NGSDR02(NGSDR03_1)
Sync Cable
GND
BTS_1800
GND
Alarm Box_1800

E1_1800
D_NGSDR02(NGSDR03_3)

BTS_Node B
Alarm Box_Node B

Optical_Node B

Sector_2_Optical_900

Optical_Node B

Sector_2_Optical_900

Optical_Node B

Sector_2_Optical_900

PWR_Node B

Sector_2_PWR_900

PWR_Node B

Sector_2_PWR_900

PWR_Node B

Sector_2_PWR_900

Example
TX Rack_1
GND
TX Rack_2
IDU_TN_1
IDU_Minilink_BSSDR03
BSSDR03_Main
IF_BSSDR03_Main
IF_BSSDR03_Main
BSSDR03_Main
DHGUL05
GND
GND_IDU_TN_2
DHGUL05_E1_1-4
DHGUL05_E1_1_4
-48 V_Rect
-48 V_IDU_TN_2
DHGUL05_E1_1-4, DHGUL05_E1_5-8
D2_NGSDR02(NGSDR03_6 CC NSRPG07_2)

RTN_2
BSSDR03_STBY
IF_BSSDR03_STBY
IF_BSSDR03_STBY
BSSDR03_STBY

GND_IDU_Minilink_BSSDR03
DHGUL05_E1_5-8
DHGUL05_E1_5-8
-48 V_DCDB_1
-48 V_IDU_Minilink_BSSDR03
DHGUL05_E1_TX_1-4, DHGUL05_E1_RX_1-4,
D2_NGSDR02(NGSDR03_6 CC NSRPG02_2)

Example
DHBDD03
DHBDD03
DHBDD03_Rectifier_Emerson
220/440 V AC
-48V DC_Battery Bank_1
GND_Rectifier_Eltek
GND_BAR_2
Alarm Cable
Mains Fail, DC Low, Rectifier Fault
-48V DC_DCDB_1
-48V DC_IVS
-48V DC_BTS_1800
-48 V_DHBDD03_TN_2
Mains_MDB
Priority /Non Priority load
Temperature sensor
smoke alarm sensor
Water alarm sensor
Temp alarm sensor
Door alarm sensor
Battery Bank_1
-48V DC_Rectifier_Eltek
GND_Battery Bank_2_BAR_1
IVS controller
IVS inlet
IVS outlet
AC_2
AC Timer
GND_BTS_2100_BAR_1
GND_Alarm Box_BAR_1
GND_Rectifier_BAR_2
GND_IVS Controller_BAR_2
GND_Battery Bank_2_BAR_1
GND_Indoor Ladder_2_BAR_1
GND_NSSDR01_TN_2_BAR_3
GND_NSSDR01_TN_2_BAR_3

GND_MDB_BAR_1

GND_ODU_BSSDR09_Main
GND_TMF_Sector_3
GND_Combiner_NGSDR20
GND_RRU_Sector_3
MDB
-440V AC_Mains
Rectifier_Eltek
AC_1
Light/Socket
Mains
Aviation light
GND_BAR_2
search protector
220/440 V AC
Aviation light controller
DCDB_1