BEHAVIOR UNDER COMPRESSION

RESULTS

Failure Pattern of CLC Cylinders

RESULTS
BEHAVIOR UNDER COMPRESSION
Peak Compressive Strength
(MPa)

Series

I
II
(only
macro)

III (hybrid)

Specimen

Mean
Comp
Strengt
h (MPa)

Std
Dev

CTI
(10-3)

Control

4.00

4.04

3.83

4.18

3.41

3.89

0.30

6.99

ma-0.2-mi-0.0

6.19

4.82

7.21

6.18

5.28

5.94

0.92

47.20

ma-0.3-mi-0.0

6.52

5.41

7.67

5.24

5.95

6.16

0.98

54.90

ma-0.4-mi-0.0

6.04

7.35

6.21

6.55

6.78

6.58

0.52

66.00

ma-0.5-mi-0.0

7.11

5.31

6.42

6.71

6.9

6.49

0.71

63.50

ma-0.1-mi-0.02

3.95

3.86

3.93

3.91

0.15

57.55

ma-0.2-mi-0.02

5.98

6.43

7.62

6.67

0.84

68.27

ma-0.3-mi-0.02

7.35

8.96

8.86

8.39

0.90

72.13

ma-0.4-mi-0.02

7.30

8.02

10.0

8.44

1.40

78.46

CTI* -Compressive Toughness Index

BEHAVIOR OF MASONRY
PRISMS UNDER
COMPRESSION

RESULTS

Masonry behavior under

BEHAVIOR OF MASONRY
PRISMS UNDER
COMPRESSION

The Peak strength shifts from being


closer to the block to that of the
centre portion between mortar and
block.
The stiffness of unreinforced prism
was lesser that of unreinforced block.
By adding fiber reinforcement the
stiffness gets improved and now lies
between that of mortar and block.

RESULTS

Masonry behavior under

RESULTS
BEHAVIOR UNDER COMPRESSION
Peak Compressive
strength(MPa)
Series

II
(only Macro)

Specimen

Mean
Comp
Strengt
h
(MPa)

Std.
Dev
(MPa)

CTI
(10-3)

Control

4.11

3.78

3.87

0.23

14.69

ma-2-mi-0.0

4.40

3.73

4.03

4.05

0.33

29.00

ma-3-mi-0.0

4.73

4.02

5.21

4.73

0.61

36.68

ma-4-mi-0.0

4.99

5.37

4.69

5.04

0.34

42.43

ma-5-mi-0.0

5.66

4.26

4.89

4.96

0.69

42.72

ma-1-mi-0.2

3.77

3.18

4.87

3.96

0.85

28.57

ma-2-mi-0.2

4.18

4.29

4.23

0.08

32.93

ma-3-mi-0.2

5.18

5.43

3.86

4.85

0.84

39.28

ma-4-mi-0.2

6.34

4.52

5.99

5.62

0.96

44.24

III (hybrid)

CTI* -Compressive Toughness Index