Professional Documents
Culture Documents
Absorber
Absorber
Absorber
Abstract
This paper considers the design of active and passive vibration absorbers for flexible structures. Similarities between
absorber design and control problems are pointed out and an approach is presented to solve the absorber design problem by
a technique that is similar to loop shaping technique used in control system design. A criterion for selecting the collocated
sensor and actuator locations is developed and the approach is extended to design of multiple absorbers. An example is
given to illustrate the results.
1. Introduction
Vibration absorbers are devices attached to flexible structures in order to minimize the vibration amplitudes at a specified
set of points. Design of vibration absorbers has a long history. First vibration absorber proposed by Frahm in 1909 [Den
Hartog, 1956] consists of a second mass-spring device attached to the main device, also modeled as a mass-spring system,
which prevents it from vibrating at the frequency of the sinusoidal forcing acting on the main device. If the absorber is tuned
so that its natural frequency coincides with the frequency of the external forcing, the steady state vibration amplitude of the
main device becomes zero. From a control perspective, the absorber acts like a controller that has an internal model of the
disturbance, which therefore cancels the effect of the disturbance.
The classical problem of damped vibration absorber that consists of a mass, spring and a viscous damper attached to an
undamped single degree of freedom (DOF) system of which the mass is subject to harmonic forcing, has a well-known
solution [Den Hartog, 1956]. If damping is added to the absorber, the vibration amplitude of the main mass cannot be made
zero at the forcing frequency but the sensitivity of the system to variations in the forcing frequency decreases. Also the
vibration amplitude of the absorber mass decreases considerably with a damped absorber.
Vibration absorbers for multi degree of freedom systems have also been proposed. In [Wang et.al. 1985], an approach is
presented to suppress vibrations in undamped multi DOF systems. Design of absorbers for beams is discussed in [Juang,
1983] and [Jacquot, 1978]. Absorber design for general vibrating systems was considered in [Kitis et. al.,1983].
In the literature, the term 'vibration absorber' is used for passive devices attached to the vibrating structure. Such devices are
made up of masses, springs and dampers. From a control point of view, vibration absorbers can be considered as passive
controllers. ( The term 'passive' is used loosely here, meaning that the controller can be constructed using masses, springs
and dampers). For such controllers stability is not an issue, since the closed loop system is also a passive one. A general
approach for the design of passive systems has been undertaken by [Juang and Phan, 1992]. Attempts have been made to
formulate the absorber design problem as an output feedback problem in the context of LQ design [Stech,1994], or in the
context of structural optimization, as a decentralized output feedback problem [Skelton et.al. , 1992] but the output
feedback problem does not have a clear-cut solution and the optimization problem posed by this formulation is a difficult
one to solve. It is possible to overcome the performance limitations of the passive absorbers by using active absorbers.
Active absorbers, consisting of sensors, actuators and a controller offer more flexibility to the designer and have better
performance, but they are more costly. A comparison of active and passive absorbers was given by [Herzog, 1994],
pointing out the performance limitations of the passive absorbers.
This paper approaches the problem of designing vibration absorbers as a frequency domain optimization problem with a
fixed order controller. A natural starting point for the design of absorbers is the specification of the sensitivity function,
which shows the reduction in vibration amplitude in the frequency domain. From this specification, absorber parameters
can be extracted solving a weighted minimization problem in frequency domain. The problem of selecting the location of
the absorber is approached by defining an 'absorber effectiveness' which has similarities with the structure selection tools
such as partial disturbance gain used in multivariable process control [Hovd, Skogestad 1992]. Finally, the case of multiple
absorbers is discussed. The similarities between the design of multiple absorbers and decentralized control is pointed out
and a design procedure is outlined.
2. Problem Formulation
a. Single Degree of Freedom Systems
Consider the system given in Figure 1. The system equations can be written in s-domain as:
F ( s) + f ( s)
= G ( s ) F ( s) + G ( s ) f ( s )
Ms 2 + Cs + K
M s 2 (C s + K a )
f ( s) = a 2 a
X ( s) = Z ( s ) X ( s )
M a s + Ca s + K a
X ( s) =
(1)
(2)
G (s)
F (s)
1 + G (s)Z (s)
(3)
Comparing equation (3) with (1), the vibration amplitude X is attenuated by a factor of
1
when an absorber is used.
1 + GZ
This is the sensitivity function S(s) used in control theory [Doyle et.al. 1991]. If F(t) = F0 Sin0t, then selecting :
Ka
(4)
C a = 0,
= 02
Ma
in Z(s), cancels the effect of F, thus giving X=0. This is the classical undamped vibration absorber. If Ca0, then the
solution for the damped vibration absorber is obtained by minimizing:
G ( j )
(5)
P( j ) = G ( j ) S ( j ) =
1 + G ( j ) Z ( j )
over all frequencies, that is, by minimizing the - norm of P(s). The solution of this problem is given in [Den Hartog,
1956] for the case of C=0. The damped absorber is less sensitive to variations in forcing frequency 0 than the undamped
one.
Another approach might be to minimize the sensitivity function around the frequency range where forcing is concentrated.
This approach will lead to the problem of minimizing | P(s)W(s) |, or equivalently designing Z(s) such that:
1
P ( j )
(6)
W ( j )
where W(j) is a weighting function describing the frequencies around which F is concentrated, and is scaled so that |F(t)|
1. Equation (6) leads to a difficult optimization problem, especially for multi-degree of freedom systems. The approach
taken in this paper starts from defining a function (s) approximating S(s) and then obtains the absorber parameters by
solving a simpler optimization problem. In addition to its simplicity, this approach gives valuable insights as to how to
select the absorber locations for multi-DOF systems, as will be explained later.
Defining the desired sensitivity function as (s), which behaves qualitatively as 1/W(s),
(s) S ( s) =
1
1 + G ( s) Z ( s)
(7)
we can write:
1 1 (s)
G ( s) (s)
(8)
A more physically motivated definition for (s) might be to define it as a ratio of the vibration amplitude of the main mass
with the absorber XWA(s) to the one without the absorber XNA(s). That is:
X ( s)
1
(9)
= WA
1 + G ( s) Z ( s) X NA ( s)
Typically (s) will have the shape of a notch filter. A possible choice for (s) for single sinusoidal forcing with frequency
0 is:
s
s
(
) 2 + 2 (
) + 1
(10)
(s) =
(s) =
((
) + 1)
A passive absorber such as the one in equation (2) cannot satisfy (8) for all frequencies, so it is reasonable to define a
criterion J to be minimized in order to obtain absorber parameters:
J =
Z ( j
) Z ( j
2
k
(11)
k =1
where k are a discrete set of frequencies around which a good fit is required and Z ( s ) is the controller transfer function,
such as the one defined in equation (2). The nonlinear programming problem posed by equation (11), along with the
constraints on parameters (for example, for passive absorbers, Ma , Ca, Ka cannot be negative), can be solved using any
nonlinear optimization scheme.
X I GI I
X = G
F FI
X A G AI
G FI
G FF
G FA
G AI 0
G FA F
G AA f
(12)
where f is the internal force transferred to the system by the impedance of the absorber:
f = Z X A
If a model system is defined by the following relationship:
X I ( s) = ( s)G FI ( s) F ( s)
(13)
(14)
using equations (12) and (13), we can solve for Z(s) as:
Z=
(1 ) G FI
G FA G AI + ( 1) G AA G FI
(15)
For the special case of XI = XA = XF = X, the above equation (15) reduces to equation (8), as in the case of single DOF
systems. Given the structure of the absorber, parameters of the absorber Z> ( s) can be obtained by minimizing (11).
XI XI fi
=
fi
F F
(16)
Evaluating the above expressions (12) to (15) we can obtain the simple expression for i :
(17)
i =
(GAI )i
1
Note that i is independent of the controller used and it can be used as a screening tool amongst the possible absorber
locations. The absorber location i with the highest | i | at the frequency of interest would be the best location for placing
the absorber, in the sense that it would decrease XI to the desired value with the least control effort. Since the factor /( 1) is common for all absorber locations, i is proportional to (GAI)i at the frequency of interest. This result is reasonable
because the absorber location with the highest GAI would have the most effect on XI. The interesting point is that the | i |,
being a function of frequency, can differ at different frequencies of interest, therefore, the 'best' absorber location for a fixed
XI can change with changing forcing frequency 0. This will be illustrated by an example later .
5. An Example
Consider the 3 degree of freedom system shown in Figure 2, with M= 1, K=4, C=0.1. A harmonic force of F(t)= F0 Sin 0t
is applied on the first mass. The aim is to minimize the effect of this force on the third mass, using a vibration absorber.
M s 2 (C s + K a )
Z ( s) = a 2 a
M a s + Ca s + K a
where Ma is specified as 1 and Ka and Ca is to be determined. For active absorbers, the controller transfer function is
defined as:
a s2 + a2s + a3
Z< ( s ) = 1 2
s + a4s + a5
where a1a5 is to be determined, with the constraint a4>0 and a5 > 0, so that the controller is stable.
The original system has natural frequencies around 0.9 and 2.5 if its damping is neglected. The frequency of external
forcing 0 will be assumed to take these values. The desired sensitivity function (s) is selected as in equation (10) with =
0.01.
The frequency response of the transfer function GAI which determines the absorber effectiveness, is shown in Figure 3 for
three different absorber locations. It can be seen that as |GAI |i varies with frequency, the 'best' absorber location changes.
Table 1 gives the absorber effectiveness |i (j0)| for the forcing frequencies 0= 0.9 and 2.5, for different locations of the
absorber. It can be seen that for 0= 0.9, placing the absorber at the third mass is the best choice, whereas for 0= 2.5, it is
best to place the absorber at the first mass. This result is not surprising if when one considers the mode shapes of the
original system. From the mode shapes of the undamped system given in Table 2, it can be seen that at the first natural
frequency 0= 0.9, the third mass attains the maximum amplitude and at the second natural frequency 0=2.5, amplitude of
the first mass is the greatest. In this example, the absorber location could have been selected observing the mode shapes,
however for general non-proportionally damped structures, mode shapes do not have a physical meaning, but the approach
proposed here still remains valid.
Location of
absorber
1
2
3
|i (0.9j)|
|i (2.5j)|
0.139
0.249
0.311
0.011
0.005
0.009
Mode 1
0.328
Mode 2
0.737
Mode 3
0.591
2
3
0.591
0.737
0.328
-0.591
-0.737
0.328
Figure 4. Frequency response of the original system, system with absorbers and the model system for 0=0.9.
Figure 5. Frequency response of the original system, system with absorbers and the model system for 0= 2.5.
Frequency
of forcing
Absorber
Location
0=2.5
0=0.9
Ka
Ca
Ka
Ca
1
2
3
0.830
0.765
0.723
0.080
0.180
0.245
6.140
6.263
6.247
0.418
0.060
0.259
Figure 6. Frequency response of the original system (dashed) and the modified system with two absorbers (solid), which are
tuned to 0=0.9 and 0= 2.5.
In the above example, absorbers act relatively independently, since they are tuned to the resonances of the original system.
When the frequencies to be suppressed do not coincide with the resonances, the iterative solution tends to create
antiresonant absorbers with little damping and with ( Ka / M a ) 1/ 2 close to the frequency of forcing. An example is given
with 01=1 and 02= 1.5, for the same structure. The parameters of the designed absorbers are : Ma1 = Ma2 = 1, Ka1 = 1.043,
Ca1 = 0.021, Ka2 = 2.313, Ca2 = 0.012.
Figure 7. Frequency response of the original system (dashed) and the modified system with two absorbers (solid), which are
tuned to 0=1 and 0= 1.5.
6. Conclusions
In this paper, vibration absorber design is considered from a control point of view. The problem can be considered as
matching a sensitivity function over a specified frequency range where the disturbances are effective, with a fixed order
active or passive controller. An approach is proposed where the desired sensitivity function is specified and then the
absorber parameters are obtained solving a nonlinear optimization problem. In contrast to many control problems, the
selection of the manipulated variables (the location of the absorbers) is not an obvious choice in absorber design for multi
DOF systems. It is shown that the 'best' absorber location is at the point where the transfer function between the absorber
force and the displacement of the mass whose motion is to be minimized, is at its maximum, at the frequency range of
interest. The approach is extended to the design of multiple absorbers, using an iterative technique that is similar to
sequential loop closing used in decentralized control.
Acknowledgement
This research has been supported by Boazii University Research Fund, Project No : 95A0640.
References
Den Hartog J.P. (1956) Mechanical Vibrations 4'th Edition, McGraw Hill.
Doyle J. C., Francis B.A., Tannenbaum A.R. (1991) Feedback Control Theory, Macmillan.
Herzog R. (1994) Active versus Passive Vibration Absorbers, ASME J. Dynamic Systems Measurement and Control V.116
pp. 367-371.
Hovd M., Skogestad S. (1992) Simple Frequency Dependent Tools for Control System Analysis, Structure Selection and
Design , Automatica, 28, 989-996
Igusa T. Xu K. (1994) Vibration Control using Multiple Tuned Mass Dampers, J. of Sound and Vibration V.175 pp. 491503.
Jacquot R.G. (1978) Optimal Dynamic Vibration Absorbers for General Beam Systems. J. of Sound and Vibration V.60 pp.
535-542.
Juang J.N., Phan M. (1992) Robust Controller Designs for Second Order Dynamic System : A Virtual Passive Approach.
AIAA J. of Guidance Control Dynamics, V. 15 pp. 1192-1198.
Juang J.N. (1984) Optimal Design of a Passive Vibration Absorber for a Truss Beam AIAA J. of Guidance Control
Dynamics V. 7 pp. 733-738.
Kitis L., Wang B.P., Pilkey W.D. (1983) Vibration Reduction over a Frequency Range. J. of Sound and Vibration V.89 pp.
559-569.
Maciejowski J.M. (1989) Multivariable Feedback Design, Addison Wesley.
Skelton R.E., Hanks B.R., Smith M., (1992) Structure Redesign for Improved Dynamic Response. AIAA J. of Guidance
Control Dynamics V. 15 pp. 1272-1278.
Stech D.J. (1994) H2 Approach for Optimally Tuning Passive Vibration Absorbers to Flexible Structures. AIAA J. of
Guidance Control Dynamics V. 17 pp. 636-638.
Wang B.P., Kitis L., Pilkey D., Palazzolo A. , (1985) Synthesis of Dynamic Vibration Absorbers, ASME J. of Vibration,
Acoustics, Stress and Reliability in Design V.107 pp. 161-166.