terminal blocks
SPD
0V
DC Earth (TE)
..
3ph 400Vac
LVBD
com
Battery Current
L1 L2 L3
L1
JP3
2
PE CON12
L1 CON11
L2 CON10
PE CON15
L1 CON14
L2 CON13
PE CON18
L1 CON17
L2 CON16
PE CON21
L1 CON20
L2 CON19
JP2
+
+
Digital Input 2
NO
Relay 1 COM
NC
NO
Relay 2 COM
NC
N
N
26
Con 1A*
*X2
Alarm I/O Connections
Ext. Alarm I/O Connections
Con 2A*
+ 1
Ext. Alarm I/O Connections Digital Input 3
- 2
+
Digital Input 4
+
Digital Input 5
+
Digital Input 6
NO
Relay 3 COM
NC
NO
Relay 4 COM
NC
NO
Relay 5 COM
NC
6 L1
7 L2
PE CON12
L1 CON11
L2 CON10
PE CON15
L1 CON14
L2 CON13
PE CON18
L1 CON17
L2 CON16
PE CON21
L1 CON20
L2 CON19
L3
Mains input
Relay 6
PS 2
8
Smartpack Power - /
CAN bus
interconnections
CAN port
Battery Current
+
-
DC/DC FP2 PS
4 DC/DC positions
273820
PS 3
8
Batt. block 1
8
Con8, pin 9-16
Batt. block 2
+24V
Built-in Battery
Temperature Sensor
Batt. block 3
242100.502
I/O Monitor
CON202*
Ext. Alarm I/O Connections
Batt. block 4
0V
Battery Monitor
242100.300
Rear connections
- 48V Outer
X:*
Battery Connections
Batt. Symmetry 1
Batt. Symmetry 2
Batt. Symmetry 3
Batt. Symmetry 4
+
+
+
+
+
Batt. Fuse
-
CAN port
8
CAN port
Battery Current
+
-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
0V Outer
Terminal
Batt.
String *N
Terminal
1
2
3
4
5
6
7
8
+
+
+
+
+
Batt. Fuse
-
- 48V Outer
Batt. Symmetry 1
Batt. Symmetry 2
Batt. Symmetry 3
Batt. Symmetry 4
X:*
Battery Connections
CAN port
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Battery Monitor
242100.300
8
NO
COM
NC
Terminal
Batt. block 1
1
2
3
4
5
6
7
8
15
CON5
System Connections
Smartpack
monitoring and
control unit
242100.118
15
Front connections
USB
CON4
Battery connections
9/15
CON3
Web/SNMP (ENET)
Batt. block 2
Customer
connections
8/26
CON2
Alarm I/O Connections
+24V
Built-in Battery
Temperature Sensor
Batt. block 3
CON1
Alarm I/O Connections
CAN port
Batt. block 4
Batt.
String 1
CON303*
Ext. Alarm I/O Connections
Relay 1
Digital Input 1
Relay 2
Digital Input 2
Digital Input 3
Relay 3
Digital Input 4
Relay 4
Digital Input 5
Digital Input 6
+
+
+
+
+
+
1
2
3
4
5
6
7
8
9
10
11
12
Relay 5
com
nc
com
nc
Relay 6
8
8
Date
CAN port
Design
21 Jan. 2010
MK
Draw
Approved
Scale
Projection
MK
CAN port
0V Outer
Terminal
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
10
0V
Battery Strings
Circuits -48Vdc
- FB4
nc
LVLD1
10
8
Con8, pin 9-16
Smartpack Power - /
CAN bus
interconnections
1
2
3
4
5
6
7
8
9
10
PE
com
*X1
Alarm I/O Connections
Digital Input 1
PS 1
1
2
3
4
5
6
7
8
9
10
11
LVLD2
PE
POS. DIST.
JP1
NEG. DIST.
L3
POS. DIST.
L2
NEG. DIST.
Chassis
PE
+
+
+
-
Power Input
7
CON1
- FB2
nc
NEG. DIST.
POS. DIST.
com
System Connection
15
- FB1
nc
SH1
1 1 1
1 4 2
CAN port
1
Sym.
CR 061103NA
Alteration
220110/MK
Date/Sign
Schematic/Connection Drawing
FP2 16kWt -48V DC/DC -48V/+24V
Eltek
Copyright A/S Eltek. All rights reserved
Replace for
Consultant
Format
A3
Page
Draw. No.
1 of 1
201001
Replaced by
Rev.