COMMENTS FOR FEEDER MAIN REPORT-FINAL ON HYDRAULIC MODELING

This is refers to the letter NRW/ICB01/Sierra/Design/2015/19 and the report on feeder main proposalsfinal.
Comments for the above report and the hydraulic model as follows,
1. Junctions' levels at the Ellie House Reservoir premises have to be corrected in the hydraulic model
as given asbuild drawings for Ellie House Reservoir.
2. DMA 2A and DMA 2B shall be isolated in the hydraulic model.
3. In the report following corrections have to be done
Page No
27
30
32

Text
DMA 11B
DMA 11B
DMA 11A

Shall be Corrected as
DMA 11A
DMA 11A
DMA 11B