Motor

RD. pin1: U
pin2: V
pin3: W
NA. pin1: +
pin2: Hb
pin3: Ha
pin4: GND

WM3885H*CA

Door Switch
NA. pin1: PTC
pin2: PTC

NA4. pin3: main wash


BL. pin1: common
pin2: AG valve
NA5. pin2: pre valve
pin3: bleach
pin4: hot valve

Part Name

Pump
BL. pin3: circulation pump
NA. pin1: drain pump
BL. pin3 to NA. pin1
1. Pump running: 120V 5%
2. Stopped Motion Pump: 0-1V

Display
pin3: GND
pin4: 12V
pin5: 5V

The part of this mark is only


for steam models.

AG Sensor
YL. pin1: GND
pin2: S
pin4: L

Heater
BL, BK. pin4: Vac (input)
BL.
pin3: steam generator
heater (input)
BK.
pin3: wash heater (input)
pin3: steam generator/
YL.
wash heater (output)
pin4: Vac (output)

Thermistor
Pin4: wash thermistor
Pin6: wash heater

Lamp
Pin1: 16.5 V

Pin1 to Pin2:

26

0 -1.2 k
Result
(tolerance 5%)
39.5 k
26.1 k
12.1 k
8.5 k
3.8 k
2.8 k
Result
(tolerance 5%)
39.5 k
26.1 k
12.1 k
8.5 k
3.8 k
2.8 k
2.1 k
1.4 k
1.0 k
0.7 k
0.4 k

Remarks
At 86 (30)
At 104 (40)
At 140 (60)
At 158 (70)
At 203 (95)
At 221 (105)

Heater: 12 -18

Test Points
WH (1) to RD (3)
WH (3) to RD (1)

Remarks
At 86 (30)
At 104 (40)
At 140 (60)
At 158 (70)
At 203 (95)
At 221 (105)
At 241 (116)
At 266 (130)
At 293 (145)
At 320 (160)
At 356 (180)

Result
0
0

WM3875H*CA
Test Points
(1) to (2)
(2) to (3)
(3) to (1)

Result
5-15
5-15
5-15

Test Points
(1) to (2)
(1) to (3)
(1) to (4)
(2) to (4)
(3) to (4)

Result
Remarks
8-12 k
8-12 k
10-15 Vdc Voltage Input
Pulsing Signal
10 Vdc
Pulsing Signal
10 Vdc

Pump

Drain pump: 10-20


Circulation pump: 18-30

Test Points
Result
(2) to (4)
700-1500
(3) to (4)
60-90
(4) to (5)
Infinity
(2) to (4)
120 Vac

Remarks
At 77(25)
At 77(25)
Voltage Input