Name of the Project : PROJECT SEABIRD (PHASE-II)


Unit : DRINKING AN DINDUSTRIAL WATER SUPPLY FACILITIES AT ARGE BAY

WATER SUPPLY FACILITIES

(Design Calculation For GLSR / OHT / Pump Capacity / Pipe sizing)


No.of Dwelling Units

Water Requirement/Unit/Day
As per norms

1170 Litres/day Considering 5 Persons/unit


and 200 LPCD

Total Requirement/Day

3000 Cu.m/day

Add 10% for Misc. consumptions

Cu.m/day

Total requirement including


Misc.consumptions

3000 Cu.m/day

GLSR
No.of Days Storage Required

3 days

Storage Capacity

9000 Cu.m

OHT
No.of Days Storage Required

0.5 days

Storage Capacity

1500 Cu.m

Water requirement in the morning hours

2000.01 Cu.m

(2/3rd of daily Requirement


i.e.,
3000 X 2/3)

Water requirement in the evening hours

1000.2 Cu.m

(1/3rd of daily Requirement


i.e.,
3000 X 1/3)

Supply hours in the morning

5 hrs.

Supply hours in the evening

2.5 hrs.

Avg. Water Demand

125 Cu.m/hr

i.e.,

3000 / 24)

Peak Demand

375 Cu.m/hr

i.e.,

125 X 3)

Peak supply rate from the OHT in the morning

400.002 Cu.m/hr

OHT filling rate > Supply rate

492 Nos.

450 Cu.m/hr

5 Nos.(3W+2SB) pumps each of cap.150 cu.m/hr @head of 55mWC

Sign :

Sign:

Sign:

Name: M.Jampali , APE

Name: B.K.Viswanath , AGM

Name: C.S.Hariharan , DGM

Prepared by

Checked by

Approved by

As on

###

Name of the Project :


Unit :

HYDRAULIC DESIGN TABLE FOR PIPELINES BY SRI. A.G.DESAI (Without modified Hazen Williams formula)

SL.
Q
No. (m3/hr)

Diameter
(mm)

1) 400.002

250

Formula for 1000m


Total head
Total head
Cross
TOATAL
Velocity
Total head
pipe length with
loss(m)
loss(m)
Velocity
Velocity
sectional C=100
LENGTH
(m/sec)
loss due to
due to
due to
(m/sec)
(m/sec) with
Area of
OF
with
friction with
Hf
friction
friction
with C=120
C=140
Pipeline
PIPELINE
C=100
C=140
11
with C=100
with C=120
Kd=1.2
Kd=1.4
=2.23418
X10
X
2
(m )
(m)
Kd=1.0
Kf=0.536
Kf=1.0
Kf=0.713
(1/d4.87036)XQ1.851851
0.0490875

Sign :
Name: M.Jampali , ADE

30.8539694759

3000

92.5619084 2.263543 65.9966407 2.71625159 49.6131829 3.1689601901

Sign:

Sign:
Name: B.K.Viswanath , AGM

Name: C.S.Hariharan , DGM

Prepared by

Checked by

Approved by