PULL OFF TEST

PROJECT:

ID:

SECTION

DATE

TIME

PERFORMED BY

STANDARD

S2

30.03.2014

05.20.PM

Sagar Chalake

ISO 4624

AIR TEMP.

REL. HUMIDITY %

EQUIPMENT

28C

53%

POSITEST-AT-M
(Manual Adhesion Tester)

COUPONS SIZE

ADHESIVE USED

COATING SYSTEM

ABBREVIATION

(5X75X150)mm

Aralditwe
Std. Epoxy Adhesive)

BARRIER 80+
PENGUARD MIDCOAT+
HARDTOP XP

A=Substrate, B=1st layer,


C=2nd layer, D=3rd layer,
Y=adhesive & Z=dolly

VALUE (Mpa)

COHESIVE
FAILURES

ADHESIVE FAILURES

RESULT

DOLLY - 1

7.88 MPa

NO

100% - C

FOUND SATISFACTORY

DOLLY - 2

11.54 Mpa

NO

100% - C

FOUND SATISFACTORY

DOLLY - 3

8.14 Mpa

NO

100% - C

FOUND SATISFACTORY

LOCATION OF TEST

BEFORE

AFTER

Customers Inspector: