DS1 1
DS1 1
DS1 1
ITEM NO.
P.A/B
MANUFACTURER
FOR
ETP II KALOL
MODEL
SERVICE
35
SPECIFIC GRAVITY AT PT :
MAX. 50
NO.OF PUMPS
REQUIRED
NO. OF MOTORS
2NOS.
REQUIRED
APPICABLE CODE/STANDARD
MIN.
MAX.
SUCT PRESSURE(KG/CM2A)
VISCOSITY AT PT (CST) :
VAPOUR PRESSURE AT PT : SAME AS WATER
DIFF PRESSURE(KG/CM2)
NPSH AVAILABLE(M)
NORMAL-10
MIN.
RATED-8
MAX.
MIN.
RATED FLOODED
MAX.
MIN.
RATED
*
WITHOUT ACC HEAD
*
ACTUAL
MAX.
50
MIN.
LOCATION : INDOOR/UNHEATED
TYPE PLUNGER
DIAPHRAGM DIAMETER (MM):NO. REQUIRED
SUCT VALVES PER FEED (type/number.)
BALL/DOUBLE
DISCHARGE VALVES PER FEED(type/no.)
:BALL/DOUBLE
CONSTRUCTION FEATURES
NOZZLE
SIZE
RATING
SUCTION
*
150#
FACING
RF
LOCATION
*
DISCHARGE
150#
RF
FLUSH
LIQUID END
SS316
PACKING:
PLUNGER
SS316
PACKING GLAND :
VALVE
SS316
NUMBER OF FEEDS
RATED CAPACITY :
LANTERN RING :
: *
*
MATERIALS
PROCESS DIAPHRAGM
TEFLON
SS316
HYDRAULIC DIAPHRAGM
*
VOLUME BOTTLE(S): SS316
MANUFACTURERS DATA
MAX. PUMP HEAD(KG/CM2)|: *
HYDRO TEST PRESSURE(KG/CM2):
*
NPSH REQUIRED(M)
*
KW RATED AT RV SETTING
*
WEIGHT (PUMP BASE, DRIVER)(KG)
SHOP TEST
TEST
WITNESSED
YES
STROKE LENGTH(MM)
LUBRICATION FLUID
CRANKCASE
HYDRAULIC FLUID
*
*
CONTROLS
TYPE: MANUAL/LOCAL
SIGNAL:
S.STATE ACCURACY
YES
INTERMEDIATE
STROKE CONTROL
REPEATABILITY
YES
LINEARITY
YES
NA
ELECTRONIC (mA)
MAX/MIN. NA
ACCESSORIES INCLUDED IN VENDORS SCOPE
1.SPEED REDUCER : INTEGRAL/SEPARABLE
5.PRESSURE GUAGE(DISCHARGE)
*
2.ELECTRONIC MOTOR : 415V/50 HZ/3PHASE,KW
,RPM
6.BASE PLATE(COMMON FOR MOTOR/PUMP/COUPLING): YES
3.RELIEF VALVE: YES
7. PULSATION DAMPNER (SUCTION): VOLUME BOTTLE
MAKE :
8.PULSATION DAMPNER DISCHARGE : VOLUME BOTTLE
SET PRESSURE(KG/CM2G): EXTERNAL/INTERNAL
4.COUPLING & COUPLING GUARD : YES
9.BACK PRESSURE VALVE
REMARKS:5. WORKING FLUID IS SOLUTION OF SPECIFIED CHEMICALS IN TUBEWELL WATER.
6. DATA SHEET IS TO BE COMPLETED BY CONTRACTOR AND PUMP MANUFACTURER AND SUBMITTED FOR ONGC APPROVAL.
7. MOC SHALL BE SUITABLE FOR THE SPECIFIED SERVICE.
8. THE DIGFFERENTIAL PRESSURE IS INDICATIVE AND SUBJECT TO REVIEW BASED ON HYDRAULIC CALCULATIONS TO BE CARRIED
OUT BY THE CONTRACTOR.
OWNER
LSTK CONTRACTOR
ONSHORE DESIGN
GROUP,ONGC,BARODA
ONGC LIMITED
REV :