Lmi System Ds 60: Hirschmann Automation and Control GMBH

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Hirschmann Automation and Control GmbH

LMI system DS 60
Electronic Control Systems:Load Moment Indicators

Product description
Type
Description
Product description

Construction type
Order No.
Technical data
Standards
Operating voltage
Display type
Inputs
Outputs
Type of termination
Interface
Environmental conditions
Operating temperature
Storage temperature
Degree of protection (IP)
Accessories

Wiring
Drawing

DS 60
Load Moment Indicator for Telehandlers (Compact system)
The DS 60 load moment indicator system was designed especially for the use in
telehandlers. The complete control and display unit is built into a housing the size
of a car radio, which can be inserted into the machines dashboard. All operating
data can be displayed on the double line dot matrix display.
CAN bus technology is used throughout the system, the advantages of which can
be found not only in the central unit, but in the sensor technology as well. In
comparison to conventional analogue technology, this technology provides added
system diagnostic possibilities which lead to shorter commissioning and service
times.
A complete system consists of three components: The central unit, a length and
angle sensor plus a four fold pressure transducer.
Each system component is connected with each other via the CAN bus through
plug connectors. A PC with a windows tool is used to configure the DS 60 system.
Using the configuration program, over 40 different extensions and up to 1000 load
charts can be entered and stored in the system. The program is easy to use.
Calibration is performed by using the console keys and menu guidance on the
display and without the need of additional tools. Access to the system software is
protected by a pin code.
In-dash housing
606351 - 24 085 06 0002
EN13000, EN50081-1, EN50081-2, EN60068-2-29, EN 60068-2-64
10 ... 36 V DC
DOT matrix LC 2x16 characters, 5mm, backlit
4x digital
4x digital, 2x relay contact (safety cut-off)
System plug
CAN-Bus, protocol CAN 2.0B, CANopen CiA DS 301, profile acc. to DS 401,
RS232 (for service)
-25 to +75 C
-30 to +80 C
IP 65 (front side with sealing)
Angle sensor WG or length- /angle sensor LWG with CAN-Interface, pressure
transducer 2-or 4-fold with CAN-Interface
CAN bus cable 5m or 11m available

page 1 of 2

page 2 of 2

You might also like