MODEL QUESTION PAPER

FOUR YEAR B. TECH. DEGREE EXAMINATION


III SEMESTER EXAMINATION
CIVIL ENGINEERING
CE206 : BUILDING PLANNING AND DRAWING (BPD)
(SCHEME 2013)
Time: 3 Hours

Max. Marks: 70
Note: 1. Answer any TWO questions from PART A.
2. PART B is compulsory.
3. Assume any missing data required suitably.
PART A

15 X 2 = 30

1. a) Explain the different factors to be considered while selecting a site for a residential
building.
b) Explain briefly about the following principles of planning
(i) Furniture Requirement (ii) Privacy (iii) Economy (iv) Aspect
2. a) State the principles underlying building bye-laws.
b) What are the requirements of Drawing/ (Living) room and Bed room?
3. a) Discuss about the planning of a high school building.
b) Write a short notes on Planning of (i) Hotels (ii) Office buildings
PART B
4.

(7)

(8)
(7)
(8)
(7)
(8)
40 X 1 = 40

For the line diagram of residential building given below, draw to scale (1:50), a fully
dimensioned plan and section along AA of a single storied residential building with the
specifications mentioned below. All dimensions in the line diagram and given in
specification are in millimeters.
(20+20)
Specifications :
Foundations overall width and depth : 1200X900
Concrete (1:4:8) bed : 1200X300
First footing : 900X300, Second Footing : 600X300 with C.R. Masonry in CM (1:8)
Basement height 600 and width 450 with C.R. masonry in CM (1:6)
Super structure: Brick Masonry in C.M (1:6), 230 thick and height 3100 (plinth to
ceiling)
R.C.C. (1:1.5:3) roof slab 100 thick
Parapet in Brick Masonry in C.M. (1:6) 115 thick and height 750 above roof
Sunshades 600 wide, to be provided over all openings in the external wall
Flooring with polished cuddapah slab over a 100 mm thick cement concrete (1:3:6)

Provide the following dimensions to doors, windows and ventilators:


D D1 D2 W V -

Paneled door
Paneled door
Flush door
Glazed window
Ventilator

1100 X 2100
1000 X 2100
800 X 1800
1200 X 1400
800 X 500

Line diagram is not to


scale.

(or)
5.

(a) Give neat conventional signs for the following items (in 40mmx40mmblocks)
(i). Stone
(ii). Concrete
(iii). Earth
(iv). Marble
(v) Brick

(10)

(b) Draw to a suitable scale fully dimensioned elevation of a fully panelled door of 1000
mm x 2000 mm
(10)
(c) Draw the Plan of a Residential building with a plinth area of 120 Sq.m. The building
is a load bearing wall structure. All External walls are in brick masonry in C.M. (1:6)
230 mm thick and all the partition walls are 115 mm thick. Plan the building as per
principles of planning to suit the following requirements:
Drawing, Living/Dining, Master Bed Room with attached toilet, Children Bed room,
common toilet, Kitchen & Internal staircase.