-MODELER/-PT DESIGN PROCESS

(a) DWG file is imported into ADAPT-Modeler.

(b) Imported drawing is converted into structural


components.
(c) Loads are applied on the structure and load
combinations are created.

(d) Support Lines are generated in two orthogonal directions.

(e) ADAPT-Modeler automatically generates Design Strips


(tributaries) for each user-defined Support Line.

(f) Design Strips are exported to ADAPT-PT.

(g) All the information required to make an ADAPT-PT run


is already entered in the Input Editor, and the program is
ready to calculate.

(h) The program finds a Post-Tensioning


Solution based on the design parameters entered
by the user. In the Recycling Screen, the user can
quickly adjust the provided tendon profile or force to
refine the solution.

(i) The user can also find a solution by defining


the number of tendons and their position
along the support line.

Stress Diagrams
Project: Pineapple Grove / Support Line 7 / Load Case: Service
1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Prestressing
Tensile Stress Positive

Allowable Stress A

Top

ADAPT - STRUCTURAL CONCRETE SOFTWARE SYSTEM


AD APT-PT Version 6.18 D ate: 2/ 24/2004 T ime: 2: 55:28 PM File: Support Line 4

Allowable Stresses

1- PROJECT TITLE Peoples

400

1.1 DESIGN ST RIP Support Line 4 Current_plane

378.8

300

2 - MEMBER ELEVA TION


[ft]

200

6.00

20.00

25.00

20.00

6.00

Stress [psi]

100

-100

3 - TOP REBAR
3.1 Us er s elected

-200

3.2 Us er s elected

-300

1 8#4X8' 6"

3.4 ADAPT selected

Span 1

Span 2

Span 3

2 15#4X11'0"

3 9#4X11' 0"

7 8#4X8'6"

4 - TENDON PROFILE

-535.3

-500

Calculated Stress

4 9#4X5'6"

3.3 ADAPT selected

-400

Span 4

Span 5

(j) Calculated stresses along the Design Strip are


displayed against the background of the allowable
stress envelope.

4.2 Datum Line


4.3 CGS Distance [in]
4.5 F orce

3.25
3.945.505.50
[296.448 kips]

1.75
[296.448 kips]

5.505.50

1.00
[296.448 kips]

5.505.50

1.75
[296.448 kips]

5.505.50
3.25
3.94
[296.448 kips]

5 - BOTTOM REBAR
5.1 Us er s elected
5.2 Us er s elected
6 11#4X9'6"

5.3 ADAPT selected

5 12#4X13'6"

5.4 ADAPT selected

6 - REQUIRED & PROVIDED BARS


6.1 T op Bars

[ in2]

required
prov ided

max 1.46
3.6

2.85

2.77

3.46

1.46

0.00

4.56

0.00

0.00

1.8

0.0
2.3

6.2 Bottom Bars

4.6

max 0.00

(k) Reinforcement for each design strip is automatically


selected by the program and displayed, specifying the
location, number and length of bars.