Professional Documents
Culture Documents
Umtscedimensioning 141007050700 Conversion Gate02
Umtscedimensioning 141007050700 Conversion Gate02
01 Apr, 2011
CE Definition
ZTEs BPC board can support 192CE for uplink and downlink respectively.
This year BPK may be used instead of BPC. BPK has 384 instead of 192 by
BPC. This is only for R99. For HSDPA special equipment is reserved.
ZTEs baseband processing board has special chip to handle the traffic of HSPDSCH and HS-SCCH. So HSDPA downlink traffic will not consume CE.
12.2k
MBMS
HSPA users
Cells supported
HSDPA
HSUPA
User
Number/throughput
BPC
192
3*4*256Kbps,
3*16*64Kbps
144HSDPA/96HSUPA
6Cell
43.2Mbps
15Mbps
CE Dimensioning Procedure
Subscribers per NodeB and traffic model will be the input of CE dimensioning.
For CS service, CE number is calculated by using ErlangB model.
Soft handover are considered.
R99
CE Factor
BPC(192CE)
SF
Bearer Rate
Uplink CE
Factor
Uplink
Downlink
64
12~17.2kbps
AMR12.2K
32
18.6~37.2kbps
3.3
CS64K
2.5
1.8
16
52.2~70.8 kbps
PS64K
2.5
1.8
PS128K
85.8~154.8
kbps
4.8
PS384K
10
1*4
169.8~711 kbps
5.7
2*4
2*2
2*2+
2*4
742.8~1448.4
kbps
1455.6~2883
kbps
2970~5742
kbps
11
28
39
Dimensioning Assumption
Traffic Model Proposed by ZTE
Bearer Types
AMR12.2K
CS64K
PS64K/64K
PS64K/128K
PS64K/384K
HSDPA/HSUPA
Unit
Erlang
Erlang
kbps
kbps
kbps
kbps
Downlink
0.03
0.003
32
400
0.03
0.003
32
600
Subscriber distribution
City
Penetration
Ratio
50%
50%
2%
2% 1%
3G sites: 132
Guayaquil
Smart phone
57440
Data Card
57492
Total
114936
Per site
57440/132=435
57492/132=435
870
Calculation Process-1
Total uplink throughput of PS64K users per site = 870 * 32 *2% = 557kbps
Calculation Process-2
CE Consumed by HSUPA
If we assume that HSUPA throughput is 400kbps per user online. Then ZTEs base
processing unit will consume 5.7*870*1% = 50CE.
If it is 3.4K signalling for HSUPA downlink and uplink associated signalling channel.
CE_DL signalling = 870*1%*0.3 = 3CE
CE_UL signalling = 870*1%*0.3 = 3CE
So total CE consumed by HSUPA will be 53CE@UL and 3CE@DL.
CE Consumed by HSDPA
For HSDPA service, ZTE base band processing board has special chip to handle the traffic
of HS-PDSCH and HS-SCCH. So traffic consumes no CE in downlink.
If it is 3.4K signalling for HSDPA downlink associated signalling channel.
CE_DL signalling = 870*2%*0.3 = 6CE
CE_DL signalling = 870*2%*0.3 = 6CE
So total CE consumed by HSDPA will be 6CE@DL and 6CE@UL
Total Required CE
If consider 30% SHO Ratio
Total Uplink CE = (20+12.5+21+53+6)*1.3=150 CE
Total Uplink CE = (20+4.5+16+3+6)*1.3=52 CE
Limited by uplink, Total CE required is 150 CE.
ZTEs BPC board can hardware support 192CE. So the base band processing resource
can meet the requirement.