1 Block flow

Screen

Raw water

Sewage

Sludge

Sludge Tank

Biological

Clarifier

SF AC

Treated

Sludge
Cake

Dewater

2 Design parameter
Item

Unit

Flow

m3/d

Sewage
250

Flow

m3/h

15

250

Inlet time

h/d

17

Operation
pH

h/d

22
7 to 7.5

BOD

mg/

400

COD

kg/d
mg/

SS

kg/d
mg/

O&G

kg/d
mg/

T-KN

kg/d
mg/

A-N

kg/d
mg/

T-P

kg/d
mg/

TDS

kg/d
mg/L

100
1,200
300
1,000
250
50
13
50
13
20
5
12.0
3
< 2000

3 Calculation
1
Treatment system
1 Coase Screen
Average flow
Max flow
Specification
2 Sewage pit tank
Capacity
Specification
Accessory
3 Sewage pit pump
Specification

4 Equalization tank
Capacity
SFAC Backwash
Total
Specification
Accessory
8 Equalization pump
Capacity
Specification
9 Fine Screen
Specification
9 Aeration tank
Flow
BOD load
Type
F/M
MLSS
Aeration tank Volume
Back check

Removal

Screen

Removal

Bio

250

0%
0%
0%
0%
50%
50%
0%
0%
0%
0%
0%
0%
0%
0%

250
250

7 to 7.5

6.5 to 8.5

6.5 to 8.5

400

95%

20

50%

10

100
1,200
300
500
125
50
13
50
13

95%
85%
85%
80%
80%
90%
90%
50%
50%
0%
0%
50%
50%

5
180
45
100
25
5
1
25
6

50%
70%
70%
70%
70%
50%
50%
10%
10%
0%
0%
10%
10%

3
54
14
30
8
3
1
23
6
0
0
5
1
<2000

17
17
10

30 m3/h *
10
m3

Treated

250

12

250 m3/d *
250 m3/d *
30 m3/h*

Removal

250

h/d *
h/d *
mm *

6
2

1.0
2.0
1

Times
Times
Lines

0.25 hour

6.5 to 8.5
25
150
100
5

BOD*5% Cut
50
6.5
BOD*1% Cut

=
=
Manual type

14.7 m3/h
29.4 m3/h

8 m3

LS

30 m3/h *

20

250 m3/d * (

65
Air mixing pipeLS

mH *

17 h - 1/

5.5

kw *

22 h ) *

2 Nos

17 h =

57 m3
7 m3/time
63 m3

m3

250 m3/d
12 m3/h *

12 m3/h*

250 m3/d /
250 m3/d line*
Conventional
0.3
2,000 mg/L
100 kg BOD/d

22
10

h/d
mH *

2.2

kw *

mm *

Lines

1
Line
400 mg/L

=
2 Nos

11.4 m3/h

Manual type

=
1,000 =

250 m3/d
100 kg BOD/d

CPHEEO 1993
CPHEEO 1993
0.35

kg BOD/kg SS d

2,000

g/m3

1,000 =

143 m3

HRT

6
12 m3/h *
160
m3
Air diffuzer, Air flow indicator

Specification
Accessory
10 Clarifier Tank
Overflow rate
Area

8 to 15

Specification
Rake Specification
Accessory

4.4
m*
4.3
m*
Reduce gear, motor
MS bridge

11 Sludge return pump


Specification
12 Filter feed tank
Capacity
Specification
Accessory

12 m3/h

12 m3/h *
7
m3

250 m3/d *
11 m3/h *

14 Sand Filter
Line
LV
Area

CPHEEO 1993
15 m3/m2/d

24 h/d)

1.2 m *

15 Activated Carbon tower


Velocities
8to10
LV
Area
Specification
SV
Volume

19.2 m2 Line
4.38 m

1.5

kw *

1 Nos

Air lift

0.5 h

6 m3

22
25

h/d
mH *

5.5

kw *

=
2 Nos

11.4 m3/h

11 m3/h Line

Lines

1.1 m2
1.18 m
( 1.13 m2 )

Lines

1.1 m2
1.18 m
( 1.13 m2)

m3/m2/hr
10 m3/m2/hr

1.2 m *
6 1/H

1.8 m3
1.6 mH

16 Treated water tank


Capacity
Specification
Accessory

250 m3/d *
25
m3

22 h /d *

2.0 h

35 m3/m2/hr
40 m3/h *
40 m3/h

15
mH *
60 min/h *

5.5
10 min

kw *

18 Treated water pump


Specification

22 m3/h *

40

7.5

kw *

Chemicals

23 m3

LS

17 Back wash pump


LV
Specification
B W water volume

1 NaCLO
Feed volume

72 m3

1 Line
1 Line

1 Line
10 m3/m2/hr

Specification

40 m3/

mH *

1 Nos
=

7 m3

2 Nos

Chemical consumption Just for Reference


12.0

Tank
Specification
Pump Specification
3

CPHEEO 1993
h

LS

13 Filter Feed pump


Capacity
Specification

m3/m2/d
12 m3/h (

Sludge Treatment
1 Sludge tank
BOD SS Sludge
SS sludge
Total DS volume
Total Sludge Volume
Volume

3
30
0.1
0.6
0.6
0.1
20

1.2 SG
mg NaClO/L
m3/d *
kg/d
L/d
L/d *
m3
mL/min *

250 m3 /d *
250 m3/d * (
152.5
kgDS/d
8 m3/d *

3.0
12.0
22
5

g/m3

h/d
d*

60 min/h
1 lines

0.2 Mpa *

kw *

400 mg/L *
500 mg/L
2.0 %
3.0

1,000.0
1.2 *

0.3
10 mg/L )

=
1 =
=
=

0.1
0.6
0.5
3

kg NaClO/d
L/d
mL/min
L

2 Nos

1,000 =
1,000 =
=
=

30.0
122.5
152.5
7.6
22.9

kg DS/d
kg DS/d
kgDS/d
m3/d
m3

Specification
Accessory

25
m3
Air mixing pipe, LS

2 Dewater
Type
Centrifugal
Operation
6
h/d
Capacity
Specification
30 kg DS/h *
Solids contents of cake
15.0 % WW
Cake volume
3 Sludge Feed pump
Capacity
Specification
4 Sludge Dry Bed
Total sludge volume
Bed Area / d
Bed Area Total
Specification

25 kgDS/h
2 m3/h *
For summer season
8 m3/d
7.6 m3/d /
19.1 m2/d *
22 m2 *

Untility
1 Mixing Blower
Air ratio
0.5 to 1.0
Sewage collection tank
10
Equalization tank
65
Sludge tank
25
Total
Specification
120
2 Aeration Blower
O2 volume
Air Volume
BC
Specification

100
6,167
160
220

m3/h/m3
m3 *
m3 *
m3 *
m3/h *

1.02 Ton/d

2.0
0.2

%
mH *

0.4
1
7

m=
days =
nos

0.8

3 m3/h *
Dryer, Filter, Regulator

4 Drain pit -2
Specification
Accessory

LS

2.0

5 m3/h *

kw *

=
2 Nos

1.3 m3/h

19.1 m2/d
19.1 m2

Ministry of land, Infrastructure, Transport and Tourism Japan


0.5 m3/h/m3
=
0.5 m3/h/m3
=
1.0 m3/h/m3
=
=
50
Kpa *
11.0
kw *
1 Nos

kg BOD/d line 3222.40.21(303/273)


m3/d
24.0 h/d *
1.1
m3 *
0.8
VVH
m3/h *
50
Kpa *
22.0

3 Compressor
Specification
Accessory

5 Drain pit pump -2


Specification

25 kgDS/h
1 Nos

kw *

0.06 =
=
=
2 Nos

0.7

MPa *

0.8

kw *

1 Nos

mH *

0.4

kw *

1 Nos

5.0
32.5
25.0
62.5

m3/h
m3/h
m3/h
m3/h

6,167 m3/d Line


283 m3/h
128.0 m3/h

m3

Submersible