GENERAL NOTES

1.All dimensions are in millimetres unless otherwise


specified.
2.All dimensions should be checked on site and any
discrepancies should be reported to the
architect.
3.All works to be carried out in accordance with
the local authorities regulations.
4.Use figured dimensions only do not scale from the
drawing.
5.Walls below 200mm thick to be reinforced with
hoop iron at every alternative course.
6.DPC to be laid under walls and to be minimum
150 mm above finished ground level.
7.All drainage pipes passing under building and
driveway to be encased in 150mm thick concrete
sorround.
8.All inspection chambers in driveway to have heavy
duty covers.
9.All reinforced concrete works to be in
accordance with structural engineers details.
10.1000 gauge polythene (damp proof membrane)
and anti-termite treatment to be provid under
ground floor concrete slab.

LANDSCAPE
COMMERCIAL

BICYCLE
RACK
WAITIN
G AREA
SIDE
WALK

13.232

S-05

S-04

7.002

S-04

S-05

CONVINENCE
STORE
3.500
7.273

2-3 M WIDE WALK WAY


INFRONT OF
CONVINENCE STORE

BOBO 2

BOB0 8

heat detectors
fire alarm

H.R

30m hose reel

D.E

Dry Extinguisher

W.E

Wet Extinguisher

S - SKIRTING.
A - 100X25mm HARDWOOD
B - 100X25mm CERAMIC TILES

SOLID FENCE

W - WALL.
A - PLASTER AND PAINT
B - FULL HIGH CERAMIC TILES

0.250
2.000

BOB0 8

smoke detectors

F - FLOOR.
F S
A - GRANITO TILES.
WC
B - CERAMIC TILES
C - CEMENT SCREED
D - CUT MAZERAS STONE

COMMERCIAL

7.064

FINISHES

S-02

12.953

S-02

GARDEN DESIGN IS THE ART AND PROCESS OF


DESIGNING AND CREATING PLANS FOR LAYOUT AND
PLANTING OF GARDENS AND LANDSCAPES. GARDEN
DESIGN MAY BE DONE BY THE GARDEN OWNER
THEMSELVES, OR BY PROFESSIONALS OF VARYING
LEVELS OF EXPERIENCE AND EXPERTISE.

TRUCK ROUTE

S-01

BOBO 1

BOBO 2

8w maintained 'EXIT' light

EXIT

E-01

10.232

S-01

Fridge

TRANSPARENT
WINDOW

Fridge
COKE

26.255

2M WIDE
PEDESTRIAN
WALK WAY

FIRE SYMBOLS
56.612

PUBLIC STREET

MAIN
ENTANCE
TRANSPARENT
WINDOW

1.Fire brigade inlet to be provided


2.Emergency lighting system to be provided
3.Smoke + heat detectors to be provided
4.Fire instruction manuals to be located at
entrances
5.A dedicated 5x400 GAL water storage
tank in the roof space shall be provided for
the hose reel system
6.A hobby automatic booster pump complete
with pressure vessel and pressure switch
shall be provided
7.Fire hydrants will be serviced on a water
reticulation of 100mm dia G.I piping class
"B" with 3 no fire hydrants
8.Exit signs to be installed above all external
doors

CAR WASH
OPENING

OVER HEAD
CANOPY

ANY SITE CHOSEN FOR A FILLING STATION


SHOULD BE SUFFICIENTLY SPACIOUS FOR IT
TO BE DESIGNED TO MINIMISE THE RISKS
FROM PETROL TO ANY PERSON LIKELY TO BE
AT OR NEAR THE FILLING STATION.

FIRE NOTES

PUMP ISLAND

BOBO 1

LOADIN
G AREA

CURB
CUT

10.414

START POINT
OF THE
STACKING
LANE

VACUUM STATION.

2.000

C - CEILING.
A - PLASTER AND PAINT

PUBLIC STREET

REVISIONS

51.933

E-02

TITLE
AS SHOWN

LEGEND

Project

PINE TREE

PROPOSED
REHABILITATIONS AND
EXTENSIONS.

Client
SHELL PETROL STATION

MAHOGANY
Title

STONE SYMBOLS
STONE MOSAIC

Architects

NAOMI RENDERS
ARCHITECTS AND INTERIOR
DESIGN CONSULTANTS

Date

NOVEMBER,
2015

J.M

Scale

Dealt

Drg no

Job no

1:100

WD - 01

GSPublisherEngine 0.11.100.100

Checked

N.M

03/13