Project:

Client:
Location:

T209 - LENTOR STATION

TriTech

CR5
RC Wall - 450mm - Type-1 at Ent - A

Tritech Consultants Pte Ltd


Made by

Date

SMN

RC WALL - DESIGN FOR SHEAR to BS 8110:1997

Page

14-Jan-16

Checked

Revision

YFM

Job No

Geometry & Design Parameters::


Thickness (h) =
Width (b) =
Ultimate Concrete Strength (fcu) =
Rebar Steel Strength:
Main Bar (fy) =
Shear Link (fyv) =
Concrete Cover =
Spacer Bar Size =

450 mm
1,000 mm
40 N/mm2
460 N/mm2
460 N/mm2
75 mm
Equals to main rebar size

Partial Factors for Material Strength (m):


Rebar (ms)=
Concrete (mc)=
Shear strength without rebar (msf)=
#1
#2
#3
#4
#1

Vertical Rebar Provided:

1.15
1.5
1.25
@

T25

150 mm c/c
(Tension)

T25

150 mm c/c

(Compression)

#2
1.45

Total Vertical Rebar % in a Cross Section =

Design Shear Force (V) =

< 2%

245 kN

Design for Shear Links:


bv =
d=
Shear stress (v) = V/(bv*d)

1,000 mm
349.50 mm
0.7 N/mm2

Link Bar Size =


No. of Legs =
Horizontal spacing of links (Sh)=
Asv =
As =

< MAX. ALLOWABLE (5)

OK

T13
3.33 Nos.
300 mm
441.99 mm2
3,272.00 mm2

100*As/(bv*d) =
400/d =

0.94
1.14

vc = (fcu/25)^0.33*[0.79*{100*As/(bv*d)}^0.33*(400/d)^0.25]/msf

0.75 N/mm2

v = 0.7

<

OK
500

<3
>1

-----> OK
-----> OK

vc = 0.75

PROVIDE NOMINAL SHEAR LINK


Provided vertical spacing along height (Sv)=
SHEAR LINKS ARE ADEQUATE

400 mm

500

OK

EUROPEAN SIZES
Metric

Mass per unit


length

Cross
Sectional

Bar Size

(kg/m)

Area (mm)

Bar Diameter (mm)

T6

0.222

28.30

T8

0.395

50.30

T10

0.617

78.50

10

T13

1.043

132.73

13

T16

1.579

201.00

16

T20

2.467

314.00

20

T25

3.855

491.00

25

T32

6.316

804.00

32

T40

9.868

1257.00

40

T50

15.413

1963.00

50