Ready and Easy To Be Installed: Single Phase Complete Solution With All Integrated Protections

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SINGLE PHASE

50 Hz

2850 min-1

READY AND EASY TO BE INSTALLED


SINGLE PHASE COMPLETE SOLUTION WITH ALL INTEGRATED PROTECTIONS

SLP

Integrated
Protection System

Dry-running

Overload

Thermal
Protection

Soft Start

4 Single-phase encapsulated
water cooled motor
No need for additional external devices or control
panels to protect the pump from dry-running
Special hydraulic designed to start with a lower starting
torque, to last longer in heavy application with abrasives
Tested for over 30.000 hours
Preset to work with any length of cable

Low Voltage

Maximum immersion depth: 150m


Maximum delivery (Q): 15000 l/h

Too Frequent
Starts/Stops

kW

P.C.*

HP

X.1-12.H2E 0.37 0.50 0.64


X.1-18.H2E 0.55 0.75 0.93
X.1-25.H2E 0.75 1.00 1.24
X.2-8.H2E 0.37 0.50 0.66
X.2-12.H2E 0.55 0.75 0.96
X.2-16.H2E 0.75 1.00 1.26
X.2-24.H2E

1.1

1.50 1.81

X.3-9.H2E 0.55 0.75 0.91


X.3-13.H2E 0.75 1.00 1.24
X.3-19.H2E

1.1

1.50 1.76

X.3-25.H2E 1.5

2.00 2.20

X.5-6.H2E 0.55 0.75 0.93


X.5-8.H2E 0.75 1.00 1.23
X.5-13.H2E

1.1

1.50 1.81

X.5-17.H2E

1.5

2.00 2.34

X.8-8.H2E

1.1

1.50 1.66

X.8-12.H2E

1.5

2.00 2.24

X.10-8.H2E 1.5

2.00 2.05

IN

V
220-230 V m3/h

0.6

1.5

2.4

4.2

6.0

(A)

l/min

10

25

40

70

100 190 250

75

66.6

27

3.0
3.1
4.4
4.6
5.6
5.9
3.1
3.2
4.5
4.7
5.7
6
8.3
8.7
4.3
4.5
5.6
5.9
8.0
8.4
10.2
10.7
4.4
4.6
5.4
5.6
8.4
8.8
10.7
11.2
7.5
7.8
10.4
10.9
9.9
10.4

220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230
220
230

*Power Consumption, **Current Consumption

ta
n
p re k
s
sw sur
itc e
ma h
no
me
ter

SLP

Recommended oversized filter for


water tanks. Available on stock!

Your local ZDS partner is:

11.4

15

Cable 15 m

Cable 45 m

PRICE

Code

PRICE

Code

PRICE

809

196070005H

920

196070005H1

1,046

196070005H3 868

113 99.9 40.5

869

196070010H

979

196070010H1

1,106

196070010H3 1013

157 138.8 56.3

958

196070015H

1,068

196070015H1

1,195

196070015H3

51.2 49.9 41.9 27.2

780

196070035H

890

196070035H1

1,016

196070035H3 808

76.8 74.9 62.9 40.8

838

196070040H

948

196070040H1

1,075

196070040H3 923

102.4 99.8 83.8 54.4

891

196070045H

1,001

196070045H1

1,128

196070045H3 1033

153.6 149.8 125.8 81.6

1,036

196070050H

1,147

196070050H1

1,273

196070050H3 1237

Code

1173

50

45.6 40.5 20.6

823

196070065H

933

196070065H1

1,060

196070065H3 946

72

65.9 58.8 29.8

891

196070070H

1,001

196070070H1

1,128

196070070H3 1096

105

96.3 85.5 43.5

1,021

196070075H

1,131

196070075H1

1,258

196070075H3 1315

138.8

126.8 112.5 57.3

1,224

196070080H

1,291

196070080H1

1,507

196070080H3 1555

36.8

33

27.7 18.2

803

196070090H

913

196070090H1

49.1

44

37

24.2

851

196070095H

961

196070095H1

1,087

196070095H3 933

79.7

71.5 60.1 39.4

981

196070100H

1,091

196070100H1

1,218

196070100H3 1120

104.3

93.5 78.5 51.5

1,180

196070105H

1,247

196070105H1

1,464

196070105H3 1295

UPON REQUEST

848

51.2

38.6 32.7 19.2

958

196070115H

1,068

196070115H1

76.8

58

1,171

196070120H

1,238

196070120H1

1,454

196070120H3

1372

1,127

196070125H

1,194

196070125H1

1,410

196070125H3

1162

48.2

49 28.8

42.6 39.2

7.9

UPON REQUEST

When extra junction is needed, please use a proper cable section; as recommended at page 28 of our Traditional Series catalogue.

Installation in Tank

Designed to prevent
ZDS pumps from
power surchages
Available on stock!

Cable 1,5 m

Delivery (Q) Outlet diameter: 1 G-F

Installation in Borehole

Designed to prevent
ZDS pumps from
power surchages
Available on stock!
SLP

ta
nk
p re
s
sw sur
it e
ma ch
no
me
ter

Model

Hydraulic data (n~2850 min-1)

C.C.**

H - TOTAL HEAD IN METERS (DYNAMIC TOTAL PRESSURE)

Shaft
Power

LENGTH (mm)

4 SINGLE - PHASE COMPLETE SOLUTION - 50 Hz

1117