Professional Documents
Culture Documents
Pressure Relief Valves: Dimensions (MM) Hydraulic Diagram
Pressure Relief Valves: Dimensions (MM) Hydraulic Diagram
Pressure Relief Valves: Dimensions (MM) Hydraulic Diagram
VMP 20
DIMENSIONS (mm)
HYDRAULIC DIAGRAM
ASSEMBLY DIAGRAM
DESCRIPTION
CROSS SECTION
OPERATION
Allows oil flow from P to T when pressure in P reaches the setting of the spring.
PERFORMANCE
Maximum flow: 100 l/min.
Maximum Pressure: 400 bar.
Application range with standard springs:
- 5 40 bar
- 20 80 bar
- 50 220 bar
- 180 350 bar
To perform setting of the valve see the pressure drop/ flow diagram.
Hysteresis: 85% of the setting value for flow capacity 1 l/min.
Oil leaks from P to T: disregardable.
Working temperature:
- min. -25C max. 90C with standard BUNA N gaskets
- min. -20C max. 200C with optional VITON gaskets
RECOMMENDATIONS
Fluid: best use mineral oil with viscosity ranging between 10 and 200 cSt.
Filter: see page Z.9000.000.
Installation: make sure to provide suitable gasket lubrication with clean oil before screwing the
cartridge on the valve body . Also make sure to screw the cartridge manually in to reach against the
gaskets in the valve body.
OLEOSTAR S.p.A. Reggio Emilia ITALY
1.1000.300
10/11/2004
RATING DIAGRAMS
ADJUSTMENTS
CODE NUMBER
VMP p / p . p
20
20Y
1.1000.300
540
2080
50220
180350
Adjustment
S
V
W
P
PV