1)
Load and Resistance Factor Design (LRFD)
(203-1)
1.4 (D + F)
(203-2)
1.2 (D + F + T) + 1.6 (L + H) + 0.5 (Lr or R)
(203-3)
1.2 (D) + 1.6 (Lr or R) + (f1L or 0.8W)
(203-4)
1.2 (D) + 1.6 (W) + f1L + 0.5 (Lr or R)
(203-5)
1.2 (D) + 1.0 (E) + f1L
(203-6)
0.9 (D) + 1.6 (W) + 1.6 (H)
(203-7)
0.9 (D) + 1.0 (E) + 1.6 (H)
Basic Load Combinations(NSCP: Section 203.3.1)
Allowable Stress Design (Working Stress Design) (NSCP Section: 203.4.1)
(203-8)
D+F
(203-9)
D + H + F +L + T
(203-10) D + H + F + (Fr or R)
(203-11) D + H + F + 0.75 [L + T + (Lr OR R)]
(203-12) D + H + F + (W or E/1.4)
0.008 kPa/mm
Floor Load
Ceramic or quarry tile (20 mm) on 25 mm mortar bed
Concrete Fill Finish (100 mm thk) (Slab)
0.023 kPa/mm
Metal Deck, 0.8 mm thk or (18 Gage)
0.14 kPa/mm
Additional Loads for Utilities, 10% of Area Dead Load
Total Area Dead Load
B. Line Dead Loads
100 mm (D= 21.2 kN/m), 3.0 m high on plastered both faces
150 mm (D= 21.2 kN/m), 3.0 m high on plastered both faces
200 mm (D= 21.2 kN/m), 3.0 m high on plastered both faces
Note: Add 0.24 kPa for single plastered face
C. Live Loads
Residential
Basic Floor Area
Exterior balconies
Decks
Storage
Office
Toilets
Classroms, Laboratory
Dining Rooms and Restaurants
Hospitals
Wards and Rooms
Lab and Operating Rooms
Corridors above ground floor
Libraries
Reading Rooms
Stack Rooms
Corridors above ground floor
Stairs
Corridors on Ground
Roof
D. Wind Load
(NSCP Section: 207.5.12.2.2 Low Rise Building)
Basic Wind Velocity,
V = 200 kph (Pangasinan)
P = qh [(Gcpi) - (GCpi)]
Where:
qh
= Velocity Pressure, kPa
GCpf = External pressure coefficient
Gcpi = Internal pressure coefficient
ection: 203.4.1)
0.52 kPa
0.10 kPa
0.20 kPa
0.10 kPa
0.12 kPa
3.40 kPa
1.10 kPa
2.30 kPa
0.11 kPa
0.40 kPa
4.44 kPa
7.80 kN/m
10.98 kN/m
14.16 kN/m
1.90 kPa
2.90 kPa
1.90 kPa
1.90 kPa
2.40 kPa
2.40 kPa
1.90 kPa
4.80 kPa
1.90 kPa
2.90 kPa
3.80 kPa
2.90 kPa
7.20 kPa
3.80 kPa
3.80 kPa
4.80 kPa
1.00 kPa