-- The accelerometer attached to the shale table was faulty and hence the accele
ration
of the shake table, i.e., the acceleration time history of the input ground m
otion
captured is incorrect.
-- However, the displacement time history of the ground motion is captured using
the wire
potentiometer and hence the input acceleration time history can be obtained.
-- Please discuss this issue with me over phone as I have an alternative method
to get the
acceleration time history of input GM
-- Note that, I have the MATLAB code for the same to get the results given in th
is folder,
so, let me know in case you need it.
-- The data given corresponds to the following ground motions:
test_1
test_2
test_3
test_4
test_5
test_6
test_7
test_8
test_9
test_10
test_11
test_12
test_13
test_14
test_15
test_16
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
-->
NF_GM02_05g
NF_GM02_01g
NF_GM06_05g
NF_GM06_1g
NF_GM09_05g
NF_GM09_1g
NF_GM10_05g
NF_GM10_1g
FF_GM01_05g
FF_GM01_1g
FF_GM05_05g
FF_GM05_1g
FF_GM06_05g
FF_GM06_1g
FF_GM07_05g
FF_GM07_1g
( 4th
-->
Accel__0 (Filtered)
( 2nd
-->
Accel__8 (Filtered)
( 5th
-->
Accel__1 (Filtered)
( 3rd
-->
WP__3 (Filtered)
( 6th
-- In addition to the 16 ground motions, a white noise test was conducted to ver
ify
the fundamental frequency of the structure. The corresponding test result is
given
in file: Wht_Noise_New_Maas_Sys.lvm