Job

:
Comparison
Location :
Mumbai
Space
:
Zone 2
Unit in Ft. :
W
Size :
0
Clean Room Class :
Filtration :
Pressure Gradient :
Lighting Load :
Occupancy :
Equipment Load :
CFM / Person :
Correction Factor :
Coil By Pass Factor. :
Fresh Air Changes/Hr.:
Weight OF Wall:
Heatload for(summmer/monsoon)
Room Air Changes/Hr.:
Glasses
Area In
Sq.ft.
Glass W
0.00
Glass E
0.00
Glass N
26.90
Glass S
26.90
Glass NW
0.00
Glass SW
0.00
Glass NE
0.00
Glass SE
0.00
Walls
Wall W
Wall E
Wall N
Wall S
Wall NW
Wall SW
Wall NE
Wall SE
Roof SUN
Roof SHA
All Glass
Partition
PartitionGl.
Ceiling
Floor
People
Eqp Load
Lights
Appliance
Product Load

Out.Air
Infiltration

Length
0
NIL
10
NIL
0.9
5
0.0
15

Area
269.19

F/C Height
10.76

Volume
2896

Micron
Watts / Sq.ft.
Nos.
KW

12

0.1
1

Row Deep Coil. :

75

GR/LB
92
162

64
28
75
48
75

60
summer
1
48 CFM
Sun Gain / Temp.
In Deg. F

'U'Factor

163

0.30

12
23
12
138

0.30
0.70
0.70
0.30

85
12
12

0.30
0.30
0.30

Heat
Btu / Hr.
0
0
433
226
0
0
0
0

Eq.Temp.
Diff. :
176.44
0.00
182.00
182.00
0.00
0.00
0.00
0.00
269.19
0.00
53.80
0.00
0.00
0.00
0.00
5
0.00
247.65
0.00

BY ANUBHAVSAXENA
16 Hours
4.00pm
Date :
Out Side
DB deg.F WB deg.F Drange
%RH
DP
Summer
96
83
32
60
0
Monsoon
85
82
88
Room
71.58
61
55
0
T :
24.42
32
Gr/Lb :
VENTILATION:
5
People
15
CFM/Per.
269.19 Sq.ft.
10.76 HT.
x
1
Select :
Effective Room Sensible Heat Factor ( ERSHF ) :

37

30
22
35
24
44
24
30
40
20
29
19
19.42
19.42
19.42
No. X
No. X
Watts X
Watts X

0.28
0.28
0.28
0.28
0.16
0.16
0.16
0.16
0.09

0.40
0.47
0.30
0.30
0.02
0.38

270 Gain/Person.
3410 Gain/KW
1
X

3.40
3.40

ROOM SENSIBLE HEAT SUBTOTAL :


Supply Duct Heat Gain :
2%
Safety Factor :
5%
Fan Heat Gain :
5%
24.42
0.10 B.F.
1.08
EFFECTIVE ROOM SENSIBLE HEAT :

1834
0
1121
1784
0
0
0
0
0
0
744
0
0
0
0
1350
0
842
0
8334
0
417
198
335
9284

9284 Effective Room Sensible Heat


=
10355
Effective Room Total Heat
Apparatus Dew Point. :( A.D.P.)
Indicated =
Selected =
Dehumidified Rise =
(1-B.F.)
x
(RM.TEMP- A.D.P.)
0.90
x
10.58
=
Dehumidified CFM =
1.08

9284
x
9.52

0.90
54
61

9.522

(E.R.S.H.)
(Deh. Rise)

Dehum. CFM =
Supply Air CFM =

903
903

Coil By Pass CFM =


CFM / Sq.ft. =
Sq.ft. / TR =

0
3.4
234

ROOM LATENT GAIN :


Infiltration
28
gr/lb
0.68
People
5 NO. X
175 Gain/Person
Steam
Lb/Hr. X
1080
Vap.Trans.
0
0.01
28
gr/lb
Permeation Load
ROOM LATENT HEAT SUBTOTAL:
Supply Duct Leackage Loss & Safty Factor :
5%
Out.Air
75
28
0.1 B.F.
0.68
EFFECTIVE ROOM LATENT HEAT :
EFFECTIVE ROOM TOTAL HEAT :
Out Side Air Heat :
T x
(1 - B.F.) x Factor = BTU / Hr.
Sensible
75
24.42
T
0.90
1.08
Latent
75
28
gr/lb
0.90
0.68
GRAND TOTAL HEAT SUBTOTAL :
Safety Factor :
0.03
Roof Sun
32
0
0
Roof SHA
8
0
Ceiling
19.42
0
GRAND TOTAL HEAT :
LOAD TR :
ROOM SENSIBLE HEAT FACTOR :
GRAND ROOM SENSIBLE HEAT FACTOR :

200
700
0
0
900
45
126
1071
10355
1780
1285
13420
403
0
0
0
0
13823

1.2
0.90
0.67

SUMMER

STATE

LAT

ALT

DAILY RANGE

DB

WB

RH%

AHMEDABAD
MUMBAI
THANE
PUNE
VADODRA

23.02

55

26

110

78

24

18.54

11

12

95

83

60

18.54

10

15

100

82

47

18.32

559

31

104

76

28

22.18
21.16

34
393

26
29

110
108

78
75

24
22

JABALPUR

MONSOON

GR/LB

DB

WB

RH%

93.5

90

85

82

177

153

85

82

88

162

138

86

83

86

168

90.5

83

79

82

145

93.5
78

88
93

79
84

68
70

136
163.8

GR/LB

DAILY RANGE

T
-30
-20
-10
0
5
10
15
20
25
30
35
40

10

12

14

16

18

20

22

-39

-40

-41

-42

-43

-44

-45

-46

-29

-30

-31

-32

-33

-34

-35

-36

-19

-20

-21

-22

-23

-24

-25

-26

-9

-10

-11

-12

-13

-14

-15

-16

-4

-5

-6

-7

-8

-9

-10

-11

-1

-2

-3

-4

-5

-6

-1

11

10

16

15

14

13

12

11

10

21

20

19

18

17

16

15

14

26

25

24

23

22

21

20

19

31

30

29

28

27

26

25

24

TYPICAL BYPASS FACTORS


WITH OUT SPRAYS

DEPTH OF COILS
(ROWS)

VELOCITY( LPM)
400
500
0.274
0.314
0.143
0.176

2
3

300
0.225
0.107

4
5

0.052
0.025

0.076
0.04

6
8

0.012
0.05

0.022

600
0.346
0.204

700
0.373
0.228

0.099
0.056

0.12
0.071

0.14
0.086

0.032
0.03

0.042

0.052

24

26

28

30

32

34

36

38

40

-47

-48

-49

-50

-51

-52

-53

-54

-55

-37

-38

-39

-40

-41

-42

-43

-44

-45

-27

-28

-29

-30

-31

-32

-33

-34

-35

-17

-18

-19

-20

-21

-22

-23

-24

-25

-12

-13

-14

-15

-16

-17

-18

-19

-20

-7

-8

-9

-10

-11

-12

-13

-14

-15

-2

-3

-4

-5

-6

-7

-8

-9

-10

-1

-2

-3

-4

-5

13

12

11

10

18

17

16

15

14

13

12

11

10

23

22

21

20

19

18

17

16

15

N.E=NORTH EAST

E=EAST

FOR WALL SURFACES

FOR 4 PM SUN TIME


EXPOSURE

WEIGHT OF WALL(lb/sq ft)

20

60

100

N.E

14

12

10

14

12

18

S.E

16

18

18

20

23

18

S.W

40

32

14

40

25

12

N.W

24

12

14

10

FOR ROOF SUN ANS ROOF SHADED


CONDITION

WEIGHT OF WALL(lb/sq ft)

10

20

40

43

41

38

COVERED WITH
WATER

18

16

SPRAYED

16

14

SHADED

14

12

EXPOSED
TO SUN

SOLAR HEAT GAIN THRU ORDINARY GLASS


FOR 20 DEGREE
SUN TIME IS TAKEN AS 4 PM

TIME OF YEAR

23 JULY & MAY 21

EXPOSURE

4:00 PM

N
N.E
E

23
12
12

S.E
S
S.W

12
12
85

W
N.W
HORIZONTAL

163
138
118

S.E=SOUTH EAST

S.W= SOUTH WEST

OF WALL(lb/sq ft)

140
14
18
16
BACK TO HEAT LOAD

13
8
10
6
2

NS ROOF SHADED

OF WALL(lb/sq ft)

60

80

35

32

14

12
8

FOR EXPOSED WALL


1/2" CEMENT
PLASTER

CEMENT
MORTAR
INSIDE
AIR FILM

OUT SIDE
AIR FILM

BACK TO HEAT LOAD

1/2" CEMENT
PLASTER

CONSTRUCTION:
OUTDOOR AIR SURFACE FILM (7.5 mph WIND)
BRICK FACING, 9 INCH
0.5 CEMENT MORTAR
SAND CEMENT PLASTER 1 in (0.5 ON BOTH SIDES)
INSIDE AIR SURFACE (STILL AIR)(VER/HORZ)
TOTAL RESISTANCE
U FACTOR

RESISTANCE
0.25
1.8
0.1
0.2
0.68
3.03
0.3300330033

MATERIAL

STILL AIR

POSITION
HORIZONTAL
SLOPING 45
VERTICAL
SLOPING 45
HORIZONTAL

BRICK FACING

4 INCH
0.8

U Factor For Floor / Ceiling


FLOOR TILE

AIR FILM INSIDE

1/2" PLASTER
4" CONCRETE SLAB

HEAT
FLOW UP
AIR FILM
CONSTRUCTION:
INDOOR AIR SURFACE FILM (STILL AIR)

1/2" PLASTER
RESISTANCE
0.61

PLASTER 0.5
CONCRETE 4
PLASTER 0.5
FLOOR TILE 1/8"
INSIDE AIR SURFACE (STILL AIR (HOR/UP)
TOTAL RESISTANCE
U Factor For Floor / Ceiling

0.1
0.8
0.1
0.05
0.61
2.27
0.4405286344

U Factor For UN-insulated Roof


OUT SIDE AIR FILM
1/2" PLASTER

HEAT
FLOW
DOWN

4" CONCRETE SLAB


1/2" PLASTER
IN SIDE AIR FILM

CONSTRUCTION:
OUTDOOR AIR SURFACE(71/2MPH WIND)
PLASTER 0.5
CONCRETE 4 in
INSIDE AIR SURFACE (STILL AIR)
PLASTER 0.5
TOTAL RESISTANCE
U Factor For UN-insulated Roof

RESISTANCE
0.25
0.1
0.8
0.92
0.1
2.17
0.46

U Factor For insulated Roof


OUTSIDE AIR FILM
HEAT
FLOW
DOWN

1/2" PLASTER
2" INSULATION
1/2" PLASTER
4" CONCRETE SLAB
1/2" PLASTER

INSIDE AIR FILM


CONSTRUCTION:
OUTDOOR AIR SURFACE FILM (7.5 mph WIND)
PLASTER 0.5
INSULATION 2 in
CONCRETE 4 in
PLASTER 0.5

RESISTANCE
0.25
0.1
5.26
0.8
0.1

INSIDE AIR SURFACE (STILL AIR)


TOTAL RESISTANCE
U Factor For insulated Roof

0.92
7.43
0.134589502

U Factor For Ordinary Glass


FOR INSIDE VENETIAN BLIND 45 DEG HORZ OR BLIND

LIGHT COLOUR
0.56

MEDIUM COLOUR
0.65

TER

ETE SLAB

TER

HEAT FLOW

RESISTANCE

UP
UP
HORIZONTAL
DOWN
DOWN

0.61
0.62
0.68
0.76
0.92

6 INCH

8 INCH

1.2

1.6

9 INCH
1.8

PER INCH

0.2

STER

ETE SLAB

STER

STER

LATION

STER

ETE SLAB

STER
ROOF INSULATION
THICKNESS(INCH)
0.50
1
1.5
2
2.5

WT(LB/SQFT) RESISTANCE(1/C)
0.7
1.39
1.3
2.78
1.9
4.17
2.6
5.26
3.2
6.67

DARK COLOUR
0.75

3.9

8.33

FOR CALCULATING CFM

APPLICATION

CFM PER PERSON

DEPARTMENT AVERAGE
DEPARTMENT DELUXE
BANKING SPACE
BARBER SHOPS
BEAUTY PARLOURS

20
30
10
15
10

BROKERS BOARD ROOM


COCKTAIL BARS
CORRIDORS
DEPARTMENT STORES
DIRECTORS ROOMS

50
30
7.5
50

DRUG STORES
FACTORIES
FIRE AND TEN CENT STORES
FUNERAL PARLOURS
GARAGE

10
10
7.5
10

HOSPITAL OPERATING ROOMS


HOSPITAL PRIVATE ROOMS
HOSPITAL WARDS

30
20

HOTEL ROOMS
KITCHEN RESTAURANT
KITCHEN RESIDENCE
LABORATORIES

30

20

MEETING ROOMS
OFFICE GENERAL
OFFICE PVT (NO SMOKING)
OFFICE GENERAL (SMOKING)

15
25
30

RESTAURANT
SHOP RETAIL
THEATER (NO SMOIKING)
THEATER ( SMOIKING)

15
10
7.5
15

FOR KNOWING THE SENSIBLE/LATENT HEAT GAIN


DEGREE OF ACTIVITY

TYPICAL APPLICATION

SEATED AT REST

THEATER

SEATED,VERY LIGHT WORK

HIGH SCHOOL

OFFICE WORKER

OFFICES,HOTELS,APTS,COLLEGE

STANDING,WALKING SLOWLY DEPT,RETAIL,OR VARIETY STORE


WALKING,SEATED

DRUG STORE

STANDING,WALKING SLOWLY BANK


SEDENTARY WORK

RESTAURANT

LIGHT BENCH WORK

FACTORY,LIGHT WORK

MODERATE DANCING

DANCE HALL

WALKING,3MPH

FACTORY,FAIRLY HEAVY WORK

HEAVY WORK

BOWLING ALLEY FACTORY

FOR OCCUPANCY
CLASSIFICATION

SQ Ft
PER
PERSON

APARTMENTS AND HOTEL GUEST


ROOMS

60

BANKS

35

DEPARTMENT STORES/MALLS

25

OFFICFE BUILDINGS

49

OFFICES SMALL SUITES

55

RESTAURANTS

22

THEATERS AND AUDITORIUMS

82F

175
SENS-180

LATENT-220

80F

78F
SENS

75F

SENS

LAT

LAT

SENS

LAT

195

155

210

140

230

120

195

205

215

185

240

160

SENS-180

LATENT-270

200

250

215

235

245

205

SENS-180

LATENT-270

200

250

215

235

245

205

SENS-180

LATENT-320

200

300

220

280

255

245

SENS-180

LATENT-320

200

300

220

280

255

245

SENS-190

LATENT-360

220

330

240

310

280

270

SENS-190

LATENT-560

220

530

245

505

295

455

SENS-220

LATENT-630

245

605

275

575

325

525

SENS-270

LATENT-730

300

700

330

670

380

620

SENS-450

LATENT-1000

465

985

485

965

525

925

70F
SENS

LAT

260

90

275

125

285

165

285

165

290

210

290

210

320

230

365

385

400

450

460

540

605

845