Lightning arresters are used to protect electrical systems from high voltages caused by lightning or other abnormalities. For an 11kV system, the phase voltage is 6.35kV RMS. The peak voltage could reach 8.98kV. Therefore, lightning arresters for an 11kV line are rated at 9kV. They act as insulators during normal operation but become conductors during voltage surges, such as from lightning, to provide a path for the surge and prevent failures of insulation in electrical equipment.
Lightning arresters are used to protect electrical systems from high voltages caused by lightning or other abnormalities. For an 11kV system, the phase voltage is 6.35kV RMS. The peak voltage could reach 8.98kV. Therefore, lightning arresters for an 11kV line are rated at 9kV. They act as insulators during normal operation but become conductors during voltage surges, such as from lightning, to provide a path for the surge and prevent failures of insulation in electrical equipment.
Lightning arresters are used to protect electrical systems from high voltages caused by lightning or other abnormalities. For an 11kV system, the phase voltage is 6.35kV RMS. The peak voltage could reach 8.98kV. Therefore, lightning arresters for an 11kV line are rated at 9kV. They act as insulators during normal operation but become conductors during voltage surges, such as from lightning, to provide a path for the surge and prevent failures of insulation in electrical equipment.
Lightning arresters are used to protect electrical systems from high voltages caused by lightning or other abnormalities. For an 11kV system, the phase voltage is 6.35kV RMS. The peak voltage could reach 8.98kV. Therefore, lightning arresters for an 11kV line are rated at 9kV. They act as insulators during normal operation but become conductors during voltage surges, such as from lightning, to provide a path for the surge and prevent failures of insulation in electrical equipment.
Lightning arrester is to protect the system from any high
voltages such as lightning. If the system voltage is 11kv, then the phase voltage will be 11/sqrt(3)=6.35kv. It means the RMS voltage of the phase. The maximum voltage or the peak voltage across the arrester and earth will be 6.35*sqrt(2)=8.98kv.i.e 9kv. Therefore, for 11kv line it is rated for 9kv. #5
when we use ac line having system line voltage 11kv,in
this case phase voltage [phase to neutral which is earthed} is 6.351 kv. lightening arrester is connected between phase and neutral. lightening arester are nothing but the voltage dependant resistors which act as insulator up to not only the phase volatage ie 6.351 kv rms but ac peak voltage reaches to 6.351 rms x root of 2 ie 1.414=8.98 kv. for normal operation of system. thus the L A s are rated for normal voltages 9 kv and discharge current generaly 10 kamp. when ever voltage surges occures due to lightenig or either by system abnormabilty,L A becomes for a instance as a conductor provides path to surge voltages and prevents failure of insulation leveles of equipment of system Is This Answer Correct ?