API 577

Visual Inspection
Personnel are required to demonstrate annually completion of a J-1 Jaeger type eye
vision test.
Direct visual examination requires access to permit the eye to be within 6 inch to 24
inch of the surface, at an angle not less than 30 degrees
Optical aid 100 foot candles (1000 lux)
One of the most popular indicators is the pie gauge. It consists of eight low carbon
steel segments, brazed together to form an octagonal plate that is copper plated on
one side to hide the joint
ACFM

ACFM is used for the evaluation and monitoring of existing cracks

It requires minimal surface preparation and can be used at elevated


temperatures up to 900 F. With its increased sensitivity to shallow cracks

Iridium 192 0.25 inch to 3.0 inch


Cobalt 60 1.5 to 7.0 inch
CE

CE less than 0.35 require no pre heat


CE of 0.35 to 0.55 require pre heat
CE greater than 0.55 - both preheat & PWHT