STANDARDISED FIELD QUALITY PLAN ‘SEQP Ro. DOC NCgaw REV, “Till next revision Page 25 of 28 Annex-5 ACCEPTANCE CRITERIA AND PERMISSIBLE LIMITS FOR CONGRETE WORK 1) | Concrete @)_ Weorkabilty ‘Slump shall be recorded by slump cone method and it shall between 25-55 ) Compressive strength 205Kgicm? and for 1:2:4 (Comont: Fine Aggregate: Course Aggregate) 1 concrete 28 days strength shail be min 210Kg/cm’, Notes : 1) AGCEPTANGE CRITERIA BASED ON 28 DAYS COMPRESSIVE STRENGTHS FOR NOMINAL MIX CONCRETE: @) On the basis of mandatory lab test result, in case of actual average compressive strength being less than specified st ‘sonerete lay be accepted and the rate payable shall be in the same proportion as the actual average compressi tual average strength of accepted sample is less than 70% of specified strength, the Engi csent by sample and nothin id for the rejected work. Remedial mn b) 2) 83.Grade cement shall be used after obtaining specie approval of the Engineer in charge. 3} Portland slag cement conforming to IS:455 may be used alter obtaining specific approval of the Engineer In Charge.