Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

5.

00

6.00

0.15

3.00

1459.016 m

1 in 60 Slope

1457.591 m

Flushing Canal
Outlet Zone
3
1

1459.016 m

0.50

1458.716 m

NWL

1458.041 m

Stone masonry in 1:4 mortar

1458.096 m

M25 RCC Lintel Beam

2.50

Inlet Zone

HFL

1459.016 m

Headrace Canal

0.90

1 in 3 Slope
Flood
Canal

0.46

3.00

1458.341 m

Settling Zone

0.40

1458.341 m

1457.266 m

0.40

NWL 1456.944 m

Spillway Crest Level (1458.096 m)

0.40

1:10

1:10

1456.516 m

0.80
1456.516 m

0.80

3.00

0.80

Spillway Chute

1.30

0.1 m thick PCC


0.2 m flat soling
75 mm thick M15 blinding concrete

SECTION B - B

Flushing Gate

4.00

PLAN

0.40

0.46

F.B. (0.3 m)

1459.016 m

1459.016 m

3.00

1459.016 m

HFL 1458.716 m

HFL

1458.716 m

NWL

1458.041 m

Stone masonry in 1:4 mortar

1458.341 m
Spillway Crest Level (1458.096 m)

NWL 1458.041 m

1:350

1:1000

1458.096 m

M25 RCC Lintel Beam

2.50

3.00

1.00

0.40

1457.591 m

1457.266 m
1

NWL 1456.944 m
1:10
1:60

5.00

1456.516 m

Sediment Storage

6.00
0.1 m thick PCC
0.2 m thick flat soling
75 mm thick M15 blinding concrete

0.80

0.15
Flushing Gate (0.6 m X 0.6 m)

meters 0

1.5

3.00

0.80

Spillway Chute

1.40

0.1 m thick PCC


0.2 m flat soling
75 mm thick M15 blinding concrete

0.2 m riprap protection


75 mm compacted soil layer

SECTION C - C

SECTION A - A
Notes:
1. All dimensions are in m, level are in meters above sea level.
2. This drawing is to be read in conjunction with the following drawings:
TKMHP-HW-01, Headworks (Plan)
3. The mark, in volume, used for concrete shall be as follows:
M15 - 1:2:4 (cement : sand : coarse aggregate)
M25 - 1:1:2 (cement : sand : coarse aggregate)
PCC- 1:2:4 (cement : sand : coarse aggregate)

1:30

1456.397 m

2
SCALE

5 meters

ALL DIMENSIONS ARE IN m UNLESS OTHERWISE SPECIFIED.

POTENTIAL STUDY OF TAWA KHOLA MHP, TAPLEJUNG


TAWA KHOLA MICRO HYDROPOWER PROJECT,97 kW
Designed: Tawa Khola MHP Study Group, CIEG 2010
GRAVEL TRAP
PLAN AND SECTION
SHEET 1 OF 1
Civil Drawings

Drawn:

Tawa Khola MHP Study Group, CIEG 2010

Checked:

Drawing No:

KATHMANDU UNIVERSITY
School of Engineering
Department of Civil and Geomatics Engineering
Tawa Khola MHP Study Group,CIEG 2010
Dhulikhel,Kavre

TKMHP-HW-04