MISCELLANEOUS TOOLS INSPECTION REPORT (MPI)

Page 1 of 1

Client

Cougar Drilling Solution

Report No

2016-203-01-056

Job Location

Cougar Yard ISB

Date of Inspection

February 10, 2016

Rig

Due Date

August 10, 2016

Insp. Ref. Standard

DS -1 Fourth Edition / May 2012, Cat 3 - 5

Test Equipment & Consumeable Detail


Equipment

Scope of Inspection
Wet Fluorescent MPI with UV Light on Ends on 8-5/16'' String Stablizer
Measurement of Tool

SX-812-75

Description / Component

9782

08/10/15

08/10/16

Intensity meter

1187

08/10/15

08/10/16

Magno meter

2257

08/10/15

08/10/16

A.C Hand Yoke

3978

08/10/15

08/10/16

UV Light

3329

String Stablizer

Counter Bore

Bore Back

Bevel f

Fish Neck LT
''Inch''

Dia.

Depth

Dia.

Cyl LT

6-1/2"

6-1/16"

18-1/4"

5-5/16"

5/8''

4-3/8"

8"

OD

Bevel f

Neck
Length

Pin
Length

Batch No 130405

BBE Mar. 2016

White Contrast

Batch No 140108
Batch No 140304

BBE Jan.2017

6-1/2"

6-1/16"

17-1/2"

4-1/2"

Connection

SRG
Dia.

Width

411/16"

7/8"

1340 W / cm2

Fluorescent MPI Ink 14 - HF

Pin

OD

Calibration & Due Date

Mag Coil

MPI Ink 7 HF
Box

Identification No.

Sr No

ID

Tong Space
'Inch'

2-7/8"

16-7/8"

Box

Tally LT
'Feet'

Pin

4-1/2" IF 4-1/2" IF

54-3/4"

Condition

BBE MAR. 2017


Remarks

Box

Pin

OK

OK

OK

COMMENTS

Found OK

Belmont Asia

Inspection Summary

Signature

1
1

Qasim Abbasi

Name

Inspector Level II MT, PT


Document Number.FO-40

Rev-01

Ea. Box OK
Ea. Pin OK
Ea. Box Damaged
Ea. Pin Damaged
Total Ends Inspected
Approved By. Fayyaz Ahmad